Do not use an air cylinder as an airhydro cylinder. Two foot brackets and a mounting nut are attached. When ordering the foot bracket, order 2 pcs. per cylinder. Clevis pin and retaining ring (cotter pin for 40) are packaged together. If it uses turbine oil in place of fluids for cylinder, it may result in oil leakage. 5.
When cylinders are used in close proximity to one another as in mounting patterns (1) through (4), the magnetic force of the auto switch magnets in cylinder B may have an effect on the operation of the auto switches on cylinder A.
Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected. 6. Do not use in an environment where there is excessive impact shock.
Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Maintenance Warning Caution 1. When using the regulator with backflow function between a solenoid valve and an actuator, check the pressure gauge periodically. Sudden pressure fluctuations may shorten the durability of the pressure gauge.
Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a cable longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply.
Keep the lead wire length as short as possible.
Holding of pressure (including vacuum) Since valves are subject to air leakage, they cannot be used for applications such as holding pressure (including vacuum) in a pressure vessel. 6. Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve.
Never disassemble or modify the ionizer, as this may not only impair the products functionality but could cause an electric shock or electric leakage. 2. The tube and fitting must be treated as consumable parts.
Note that an ejectors flow rate is smaller than that of the vacuum regulator, and therefore, it is not suitable as a vacuum supply. Tightening torque of Phillips screw for mounting bottom bracket Air Supply Caution 1. These products are designed for use with air. Please contact SMC if any other fluid will be used. 2.
The valve arrangement is numbered as the 1st station from D side. Indicate the valves to be attached below the manifold part number, in order starting from station 1 as shown in the drawing.
When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. Mounting Warning 1. Be certain to connect the rod end to the load with the lock released.
Do not use a pneumatic type as an air-hydro cylinder. It can cause oil leakage. 2. Mount the rod boot so that it will not be twisted.
Real-time switch output, accumulated switch output, or accumulated pulse output can be selected as an output type.
These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion. Pressure Setting Caution 2. Do not use in an environment where a strong magnetic field is present. 1. The switching setting indication scale shows the set value for pressure decrease.
Tube The following instructions must be followed during maintenance: Turn off the power supply Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance work Otherwise an injury can result. longer, the set value is displayed as [-], and the set value will be the same as the current pressure value automatically (snap shot function)
If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident.
How to Order AS 200 1 F G 06 Body size Applicable tubing O.D.
(Operating condition) Therefore, the cycle time can be obtained as follows.
Twice as strong as the conventional models.