Be certain to adopt a reliable connecting method if the rotary actuator is used very frequently or if it is used in a location that is exposed to a large amount of vibration. 5. There may be cases in which a speed reduction circuit or a shock absorber is required.
D-F9 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 Switch Hysteresis D-F9W 6 15 19 41 46 43.5 Proper auto switch mounting positions (Series CEP1 ) (mm) Bore size (mm) 12 Auto switch model Symbol 20 A B A B A B A B A B A B A B 75.2 82 Switch operating position (ON) D-A90, A93, A96 7.9 12 75.2 82 D-A90V, A93V, A96V 7.9 12 Hysteresis Reed switch: 2mm or less Solid state switch: 1mm or less 79.2 86
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 4.
Brown 2 A B-1 Cable length (L) Red 1 A A-1 Orange 6 B B-2 Yellow 5 B A-2 8 8m *1) Green 3 COM-A/COM B-3 A 10m *1) Blue 4 COM-B/ A-3 B 15m *1) Shield Cable color Terminal no. C 20m *1) Vcc B-4 Brown 12 GND A-4 Black 13 A B-5 Red 7 *1) produced upon receipt of order. A A-5 Black 6 Only Robotic type cable can be selected.
A C B A C B Stroke A operation 1) Initial state (0 stroke position) 1) Initial state (0 stroke position) Stroke B Stroke A Stroke B Stroke A A A 2) 1st stage: Stroke A operation When the air pressure is supplied from the A port, the rod operates the stroke A. 2) Operation When the air pressure is supplied from the A port, the rod operates the stroke A.
SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.
Coil with a full-wave rectifier (electrical option R) (mm) Grommet Conduit DIN terminal Conduit terminal Electrical entry (DC, AC) Applicable flange Model M A B C D E F H J K L N 22.5 25.5 25.5 M N 43 46 46 M 89 N 61.5 64 64 Q 49.5 52 52 M N 95 98 98 Q 64 66.5 66.5 Normally closed VXD2272 VXD2382 VXD2392 Normally open VXD2270 VXD2380 VXD2390 32A 40A 50A 12 14 14 35 40 40 22.5 25 25 67.5 70
Example) XLA-25H0-2M9NJLA-XAN1A 18 XLm Series Dimensions XLA/F (With D-M9mJm) C E E C E Fn D Heat-resistant auto switch H B A Heater G A [mm] Series Valve size A B C D E Fn G H 25 50 121 48 27 12 40 26 44 40 65 171 66 39 11 55 41 67 50 70 185 79 46 11 75 52 72 XLA XLF XLC/G25, 40 (With D-M9mJm) XLC/G50 (With D-M9mJm) C E C E E C E E C E Fn B A Fn D D Heat-resistant auto switch H J K H B A
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
When in need of a valve with a lead wire longer than 600 mm, place an order for a valve without a connector and connector assembly. Note) Mounting screws are attached.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
For Air How to read the graph The sonic range pressure to generate a flow rate of 100 l/min (ANR) is P1 0.1 MPa for a 3 orifice (VX313), P1 0.23 MPa for a 2.2 orifice (VX312), and P1 0.55 MPa for a 1.5 orifice (VX311).
:U 42 boc~~ze . d 1-1 B C D 27 28~oe. 72ji Y-14A 140 8 48 105 M30 x 1.5 47 36:21 NT-12 125, 140lM30 x 1.5 18 46 53.1 44 30 NT16 160 /M36x1.5 21 55 63.5 53 M36x 1.5 32 ~~' 4072J Y-16A 110 80~J 34 46 ' 1 160 8 55 * Use a single knuckle 101n1 or a double knuckle JOint Individually.
Applicable bore size (mm) d H B C D 125 140 160 +0.084 0 +0.3 +0.1 0.1 0.3 Y-12A Y-14A Y-16A 8 46 27 42 25 32 64 100 M30 x 1.5 +0.084 0 +0.3 +0.1 0.1 0.3 NT-12 NT-16 125, 140 160 18 46 53.1 44 8 48 30 47 M30 x 1.5 28 36 72 105 M30 x 1.5 +0.1 0 +0.3 +0.1 0.1 0.3 21 55 63.5 53 8 55 34 46 M36 x 1.5 32 40 80 110 M36 x 1.5 Use a single knuckle joint or a double knuckle joint individually.
Extend the dimensions of A and H, when using a single/double knuckle joint together with a rod end nut.
A 13 10 41.5 [48.5] (Pitch) P=10.5 13.5 M3 x 0.5 (A port) A A 13 10 (Pitch) P=10.5 11.5 M3 x 0.5 (A port) L plug connector (L) M plug connector (M) M8 connector (W0) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer to the page 68 for dimensions with connector cable.
o Drain A r t i SMC K P C U O S L H o t A Drain Component Parts No.
/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.
4 #1@3@9 Section A-A A MY3A MY3B MY3M A $0 $1 #4 #5 #2 @1 $6 $3 Component Parts No. 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 55 56 57 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 16 17 18 19 20 21 23 24 25 26 27 28 Description Magnet Magnet Seal magnet Rail End spacer Square nut Square nut Spring pin Parallel pin Note Hard anodized Hard anodized Hard anodized Hard anodized Hard