SMC Corporation of America
Elite Part Number Search
Search Results "HRS090-W-20-BJ"

Screw Attached)], Pump System PE Port Female Thread: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: Vacuum Break Flow Adjustment Needle Round Lock Nut Type, Manifold Common Release Pressure Supply: -

Screw Attached)], Pump System PE Port Female Thread: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: Vacuum Break Flow Adjustment Needle Round Lock Nut Type, Manifold Common Release Pressure Supply: -

Main Body Shape: Unit, Additional Function: Filter / Valves for Vacuum Generation / Reverse Check Valve/Vacuum Retention / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -91, Air Consumption Flow Rate(l/min): 24, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: 1/4 (Ø6.35), Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector

.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Optional Specs. 1: B+J, Optional Specs. 2: -

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Optional Specs. 1: B+J, Optional Specs. 2: -

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Optional

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector

.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Optional Specs. 1: B+J, Optional Specs. 2: -

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector

.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Optional Specs. 1: B+J, Optional Specs. 2: -

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector

.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Optional Specs. 1: B+J, Optional Specs. 2: -