1 5 Port Air Operated Valve Series VFA3000 How to Order SA Thread type (Including pilot port) VA Nil F N T Rc G NPT NPTF SA Port size (P, A, B port) VA 01 02 1 8 1 4 Option R1, R2 port are 1/8.

160 50 140 Lateral load N 40 120 Lateral load N Point of application L 30 100 20 80 Lateral load F 10 60 40 80 70 60 50 40 30 30 20 Point of application L mm 80 60 40 120 100 Point of application L mm 4 Escapements Series MIW/MIS 12, 20 How to Order Finger options Nil: Basic type (Standard type) 1: Tapped on upper and lower faces 2: Tapped on all faces (5 surfaces including end surface)

apply onty to a ct6rn, sa tub crt6d vatve, DESIGN Thls dsslgn conospt constsls of a Match.cround .:SPOOL & SLEEVE,, assembly which controls the main valving functions.

Bore Piston Area Forces (lbs); Push Stroke (in) (in) Operating Medium Pressure (psi) 50 60 80 100 200 250 How to use this table q Locate column with desired operating pressure. w Move down that column and locate the thrust value which is equal (or the next larger to the force to be delivered by the cylinder). e On that same line, locate in the first (left) column the bore size recommended

M plug connector Rated voltage 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 2 3 4 5 6 7 9 Solenoid valve configuration Single solenoid Double solenoid Closed center Exhaust center Pressure center Manual override 1 2 3 4 5 24 VDC 12 VDC None Locking B type Locking C type Nil B C 240 VAC, 50/60 Hz Other Without auto switch B S 50 90 1 1 G CVRA1 B S 50 90 1

Keyway dimensions l b Model Port size Rc A B C F H J K S U W BA BB CA CB SA SB SC SD SE DD (h9) D (g6) CDRA1BS50 CDRA1BS63 CDRA1BS80 CDRA1BS100 5 5 5 5 36 41 50 60 2.5 2.5 3 4 25 30 35 40 8.5 10 12 12.5 25 30 40 45 15 17 20 25 8.5 10 12 12.5 34 34 34 34 46 57 70 85 17 20 23.5 25 33 33 33 33 14 21 29 39 62 76 92 112 48 60 72 85 M8 x 1.25 depth 8 M10 x 1.5 depth 12 M12 x 1.75 depth 13 M12 x

K Note 2) Negative common N Note 3) Coil voltage CE-compliant External pilot R Note 3) Note 5) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 381 for power consumption of AC type.

Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.

Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.

SA VA SA Selection Caution One-touch Fitting VA Operation method: The valve must be switched to OPEN or SHUT instantly and securely. Stopping the handle halfway between the extreme positions may cause malfunction. 1.

40 40 50 62 3 4 5 8 10 12 9 10 11 8 10 12 16 20 24 20 22 29 33 43.5 51.5 19 21.5 23 33.5 34 34.5 8 5 to 50 11.5 5 to 50 H J L P Q QA R S SA T W Y Z Model ZC(D)UKD16 ZC(D)UKD20 ZC(D)UKD25 ZC(D)UKD32 ( ): In the case of a mounted auto switch.

Addl weight per each 2" of stroke NCA For all mountings style 0.38 0.48 0.51 0.97 1.06 DCylinder Bore and Force: Push Stroke -X Force (lbs); Push stroke Bore size (in) Piston area (in) Operating medium pressure (PSI) 2050 60 80 100 200 250 Data 1.5 1.767 88 106 141 177 353 442 2 3.142 157 188 251 314 628 785 2.5 4.909 245 295 393 491 982 1227 To calculate pull forces not shown in the table

3 Port Air Operated Valve Series SYJA300 How to Order SA Bracket VA With bracket F Nil Without bracket SYJA3 2 1 M3 Body ported SA VA SYJA3 4 1 Base mounted VM VR Port size Type of actuation Nil Without sub-plate VH Normally open Normally closed 2 1 M5 port with sub-plate M5 VHS How to Order Manifold Base Same manifolds as Series SYJ300 are prepared. SS3YJA3 Fill the same as SS3YJ3.

SA VA SA Selection Caution One-touch Fitting VA Operation method: The valve must be switched to OPEN or SHUT instantly and securely. Stopping the handle halfway between the extreme positions may cause malfunction. 1.

Valley Hwy, Suite H-100 Kent, WA 98032 TEL: (425) 251-6955 FAX: (425) 251-6801 ITALY SMC Italia SpA FRANCE SMC Pneumatique SA HOLLAND SMC Controls BV SMC Corporation of America (Austin) 9101 Wall Street, Suite 1030 Austin, TX 78754 TEL: (512) 926-2646 FAX: (512) 926-7055 SMC Corporation of America (Milwaukee) 16850 W.

Addl weight per each 2" of stroke NCA For all mountings style 0.38 0.48 0.51 0.97 1.06 DCylinder Bore and Force: Push Stroke -X Force (lbs); Push stroke Bore size (in) Piston area (in) Operating medium pressure (PSI) 2050 60 80 100 200 250 Data 1.5 1.767 88 106 141 177 353 442 2 3.142 157 188 251 314 628 785 2.5 4.909 245 295 393 491 982 1227 To calculate pull forces not shown in the table

-5 S07A0-5 S07A0-5 4 72 62 39 12 12 12 12 12 5 4 x M4 mounting hole Stations D side 1 2 3 4 5 6 7 8 n U side Circular connector cable assembly 3(R) port C8: 8 (For A, B port metric size) N9: 5/16" (For A, B port inch size) AXT100-MC26-015: 1.5 m AXT100-MC26-030: 3 m AXT100-MC26-050: 5 m DIN rail clamping screw 60 60 33.6 17.5 18 (12) 9.6 6.5 8.5 17.2 (7.5) 2n x C2, C3, C4, N1, N3 (4(A), 2

5 Port Solenoid Valve Connector Type Manifold Metal Seal / Rubber Seal IP67 enclosure compatible [Option] Power saving Power saving RoHS compliant Standard: 0.4 W Standard: 0.4 W (Reduced by 60% compared to existing model) (Reduced by 60% compared to existing model) High-pressure (1 MPa, Metal seal): 0.95 W High-pressure (1 MPa, Metal seal): 0.95 W Series VQC1000/2000 CAT.ES11-101A Connector

Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.

Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.