SMC Corporation of America
Elite Part Number Search
Search Results "CLK2GA50-50YA-BR-P"

<br>After setting the pressure, be sure to lock the knob.<br>Moving the knob in the downward direction may cause the pressure to drop below the initial setting.<br>The knob rotates clockwise to increase pressure and counterclockwise to decrease pressure.<br>The setting range of the outlet pressure is 85% or less of the inlet pressure.

<br>For example, for the ITV2030 (0.5 MPa type), to set the pressure to 0.3 MPa, send (0.3 MPa/0.5 MPa) × 4095 = 2457 (DEC) = 999 (HEX) data “999” from the master PLC to the regulator.<br>Note) DEC is decimal, and HEX is hexadecimal.<br>③ ITV series CC-Link compatible products come with Bus adapters.<br>The part number of the Bus adapter is “EX9-ACY0-MJ.”

<br>As a guideline, when there is no volume, it is about 0.4 seconds.<br>For the ITV1000 and ITV2000, there is a high-speed response time type available using the special order part number suffix “-X88.”<br>For this product, as a guideline, when there is no volume (no load), it is about 0.1 second.

<br>③ If the input signal of the old IT series product was a 2-wire type current type, only 4 to 20 mADC signal wiring was required, with power supply wiring not required.<br>In this case, the ITV series regulator will need to be connected to a power supply.<br><br>The ITV1000/2000/3000 series catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-regulators&fa_id=11155

<br>After setting the pressure, be sure to lock the knob. Moving the knob in the downward direction may cause the pressure to drop below the initial setting. <br>The knob rotates clockwise to increase pressure and counterclockwise to decrease pressure. <br>The setting range of the outlet pressure is 85% or less of the inlet pressure.

<br>Replace each product as a whole. <br><br>The production of old AW series (2 digits: AW□□) bowl assemblies has also been terminated, and the supply is limited to whatever is left in stock. <br>Please check the part number of the bowl assembly and confirm whether it can be ordered. <br>If the current stock has run out, replace each product.

<br>It is recommended that the cartridge be replaced if the error occurs again even after cleaning the electrode.<br>Note) Be sure to stop supplying power when cleaning or replacing the emitter.<br><br>

ca_id=161" _blank>catalog<br><br>Note 1) You can change the electrical entry direction in 90° increments by adding XC□ to the end of the part number.<br>Note 2) In the case of a product with bracket, the end of the part number is XB□.<br>(For the applicable models, refer to the catalog.)

<br>Note) For pilot air pressure, refer to the “Specifications” section in the catalog of each series. <br>Reference) SGC and SGH series coolant valve PE ports have a filter mounted as standard.<br><br>

<br>Follow the procedure below to adjust the flow rate. <br>For the automatically operated type<br>Install a needle valve or other flow adjustment valve on the outlet side of the process pump to adjust the flow rate.

<br>Note) The water-regulating valve of HRS□-W water-cooled thermo-chillers opens and closes depending on the state of the circulating fluid. It opens and closes according to changes in the refrigerant pressure. <br>Facility water will not flow at the start of operation or when the heat load is low.<br><br>

<br>However, if the same alarm or multiple alarms are generated frequently, please contact your local SMC sales office. <br><br>Note 1) These are the default settings of the HRS050. The operating settings can be changed by the user. <br>The default setting for alarm code “AL08” is stop operation for the HRS090 to 200.

SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state.  CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line.  The CLK2 is capable of being locked at any position within the entire stroke.  A dedicated

Clevis Width: 12mm, ø32; 16.5mm, ø40, 50, 63, Bore Size: 50mm, Port Type: Rc1/4, Stroke: 75mm, End Bracket: Double Knuckle Joint, M6 w/o Tap, Option: None, Locking Direction: Extension Locking, Unlock Port Position: Top (Retraction Locking: No; Extension Locking: Yes), Switch Mounting Rod Position: Top, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired