<br>The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type). <br>For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.” <br>Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=combination-units&fa_id=10974
<br>④ The pipe length from the strainer to the liquid collector body is 20 m or more when the mounting height of the liquid collector is 3 m or more for a water-soluble solution or 1 m or more for an insoluble solution. <br>⑤ The dynamic viscosity of the fluid is too high to flow. <br>⑥ The operating fluid is air. (Air cannot be used as the fluid.
<br>Classification of a Class 2 pressure vessels is as follows.<br>① The internal capacity exceeds 40 L.<br>② The internal size exceeds 200 mm and the length exceeds 1000 mm.<br>③ The container holds gas with an operating pressure of 0.2 MPa or more.<br><br>Ref.) The capacity of the VBAT series air tank does not exceed 40 L.
<br>Note) The KK□ series S coupler cannot be used as a stop valve that requires zero leakage. Due to the specifications of the product, a certain amount of leakage is unavoidable.<br><br>
<br>Note 3) If the surge pressure is higher than the max. operating pressure, it may cause damage to the fitting or tube.<br><br>
<br><br>Meter-in control is a control method in which the speed of the cylinder is controlled using the cylinder supply flow rate.<br>With meter-in control, the exhaust conditions do not affect operation, and the piston can start moving quickly. (Cylinder lurching can be prevented.)
<br>Note) The accuracy will decline if IN side piping deviating from the recommended straight piping length or bore size is used.<br><br>
<br>The VX3 series catalog can be found here.<br><br>
<br>Be sure to check the specifications and precautions listed in the catalog of each type of tubing and fitting. <br>Note that LQ series piping requires a special tool. <br><br>
<br><br>Fittings and tubing catalogs can be found here.
<br>In this case, use the bypass piping set (optional accessory) to secure the flow rate. <br>Note) The temperature stability is as follows: ±2.0℃ for the HRSE, ±0.5℃ for the HRS090, and ±1.0℃ HRS100/150/200.<br><br>
<br>First, refer to the “Transport and Setting Up” section in the HRS series operation manual. <br>Wiring examples are shown in the “Wiring of remote operation signal input” and “Wiring of run/stop signal input・Remote signal input” sections. <br>Next, to enable remote signal input, change the communication mode from “LOCAL” to “DIO” mode.
<br>Please check the figure below. If the product is equipped with a control power supply, this control power supply circuit is provided. <br>If the operating power supply voltage is energized while the valve is open, it is acceptable not to drop it to the holding voltage.<br><br>
SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state. CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line. The CLK2 is capable of being locked at any position within the entire stroke. A dedicated
<br><br>・While it is possible to mount a G36-10-01 or G46-10-01 pressure gauge on a VEX113□/123□ series regulator, it will be larger than the width of the product body.<br>・It is also possible to mount a G46-10-01 pressure gauge on a VEX133 □ series regulator so long as it does not interfere with the piping.
<br><br>For plug lead type manifolds:<br>The max. number of stations that can be increased depends on the wiring kit.