SMC Corporation of America
Elite Part Number Search
Search Results "CHDSGFY32-400-B-M9BWSDPC"

Change of fluid passage Flow Characteristics Flow characteristics 1 2 (P A) C [dm 3/(sbar)] 27 38 Port size 2 3 (A R) C [dm 3/(sbar)] 27 40 2 1 (A P) C [dm 3/(sbar)] 25 40 3 2 (R A) C [dm 3/(sbar)] 26 38 b 0.38 0.30 b 0.37 0.32 b 0.36 0.22 b 0.37 0.20 Cv 7.0 9.8 Cv 7.4 9.8 Cv 7.3 9.8 Cv 6.8 9.6 1/2 3/4 N.C. N.O.

Rod End Nut (mm) Trunnion Nut (mm) Mounting Nut (mm) H Material: Carbon steel Material: Carbon steel Material: Carbon steel d d B D D C C C D H B H B d Applicable bore size 20 25, 32 40 Applicable bore size 20 25, 32 40 Applicable bore size 20 25, 32 40 B C D d H D d H C B d H B C D Part no. NT-02 NT-03 NT-04 Part no.

B B B B B B RE A B 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7)

Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow rate characteristic graphs.

Note 1) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. Note 2) 200 V type only. 400 V type is CE-compliant as standard. Additionally, combination with option B is not necessary. An earth leakage breaker is equipped as standard.

Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160

pressure 400 kPa Supply pressure 400 kPa 10 10 10 0 0 0 0 40 80 120 160 200 0 200 400 600 800 1000 0 100 200 300 400 500 Flow [L/min] Flow [L/min] Flow [L/min] Straight Piping Length and Accuracy PFMB7201/7501/7102 Straight piping length IN OUT (8 cm or more) p6 p5 Accuracy [%F.S.] p4 p3 The piping on the IN side must have a straight section of piping with a length of 8 cm or more.

B B B B B B 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7) 7.5 (4.5) 7.5 (4.5) 12 (8) 15 (10.5) 17 (13) 3 (

cable O.D.: 6.8 to 11.5) CE1 CE2 Proper Auto Switch Mounting Position D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C ML2B D-G39 D-K39 D-A33/A34 D-A44 D-B5 D-B64 D-B59W D-G5NTL Bore size (mm) C J G5-S A B A B A B A B A B A B CV 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 25 MVGQ 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5

N.C. and N.O. common 2 x Rc (d) Removal dimension G INLET INLET B C E (F) B N COM. N.O. N.C.

The initial value is " A: A contact (normally open)(output 1,3) / B: B contact (normally closed) (output 2)".

x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8 m/s2] M2 M1 M3 m x g m x g Guide shaft mounting surface Guide central axis m x g Cylinder

x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8 m/s2] M2 M1 M3 m x g m x g Guide shaft mounting surface Guide central axis m x g Cylinder

Outside Inside the controller 10k (a) 1k (a) IN0 to SVON (b) (b) COM Caution Unused input terminals should not be in an unconnected (open) state.

This item is U n i t N u m b e r M O D E < 0 applicable only when multiple units are used. 2. Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.

B Supply pressure and the Stopper screw (Do not move) OUT1 output are connected by rotating the Auto/Manual changeover screw towards M.

IODD file 1 D-MP025A/B/C SMC-D-MP025-ymmdd-IODD1.1 2 D-MP050A/B/C SMC-D-MP050-ymmdd-IODD1.1 3 D-MP100A/B/C SMC-D-MP100-ymmdd-IODD1.1 4 D-MP200A/B/C SMC-D-MP200-ymmdd-IODD1.1 : "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.

H 4 S y m b o l Initial power / Power consumption (W) 100 VAC 200/40 200/50 400/100 200 VAC 800/40 800/50 800/100 Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C.