Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 3

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9B,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9B,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: M9B, Lead

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200/100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification: Without end lock (standard

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Magnet: Built-in, Mounting: Rear Trunnion, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Front Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Rubber Bumper, Bore Size: 20mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 20mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Bore Size: 25mm, Stroke: 100mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rear End Lock Non-locking Style, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Bore Size: 40mm, Stroke: 100mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rear End Lock Locking Style, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Single Clevis, Bore Size: 40mm, Piping: Screw-in, Stroke: 100mm, Cylinder Rod Motion: Energized Extend, Rod Boot: None, Function: 3 Position Exhaust Center, Valve Voltage: 110VAC, Electrical Entry: DIN Terminal, Light & Surge Suppressor: Light & Surge Suppressor, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, HYDRAULIC, OTHERS, CH HYDRAULIC CYLINDER, MD, 40MM CH DOUBLE-ACTING, 11.73740 lb

CH2 double acting hydraulic cylinders conform to JIS B 8367 specifications. Surge pressure generated when running into the cushion has been reduced by 30% or more compared to the CH series, due to the CH2s cushion seal system. Separate construction of the rod cover simplifies maintenance. Available in bore sizes 32mm to 100mm. All series types are available with auto switch capability