E C Padlock mounting position C D D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SUP SUP . A OUT IN A OUT IN 1 2 B 3 B EXH. EXH.
The materials in parentheses are the seal materials. 21 22 Direct Operated 2 Port Solenoid Valve Series VX21/22/23 For Water, Oil, Steam Dimensions: Single Unit/Body Material: Brass, Stainless Steel Normally closed (N.C.): VX210/VX220/VX230 Normally open (N.O.): VX212/VX222/VX232 Grommet: G Conduit: C Approx. 280 Q D F Approx. 300 Q D F G1/2 25 25 Width across flats H R (C) C C R Width across
WA WB View E NN F GB GC GA Mounting nut Mounting nut Relief port M5 x 0.8 Rod end nut MM NN F Piping port 2 x M5 x 0.8 Cover surface D LY LB LH LT LZ LX LT S + Stroke H NA A NB Y X Y X 4 x LC Mounting hole LS + Stroke Z + Stroke WW C B 0 0.3 B 0 0.3 Drawing of view (E) (mm) Z S WW WB WA NB NA NN MM H GB GA F D C B A Y X 91.5 92.5 LS LZ 42 42 25 25 LY LX 33 33 2.3 2.3 LT 14 14 LH 5.5 5.5 LC
Electrical entry TT is approved for Class I, II, III, Division 1, Groups A, B, C, D, E, F, G. Electrical entry L and LL is approved for Class I, Division 1, Groups A, B, C, D. 4.
30.5 31.5 18.5 19.5 Grommet (Perpendicular) Reed switch Model Model 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 D-A90V 5 25.5 26.5 13.5 14.5 A B A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.
Auto switch types D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Standard strokes (mm) Bore size (mm) 40 50 63 80 100 125 160 25 to 800 25 to 800 25 to 800 25 to 1000 25 to 1000 25 to 1000 50
9 16.5 19 15 23 6 Width across flats 10 39 19 (4 locations) K (58) 25 19 8 Closed E 9 9 25 Open F 13 13 43 G 4 x M5 x 0.8 through (Thread for mounting attachment) Model A B C D E F G H J MHL2-16DZ 40 45 60 28 68 98 128 26 98 MHL2-16D1Z 70 75 90 58 110 170 200 50 152 MHL2-16D2Z 90 95 110 78 130 210 240 70 192 J dimension is at fully closed.
Kit designation CU1 Note 1) C Stations Kit (connector) CU2 Note 1) 02 2 stations Direct exhaust with silencer box: D and U side exhausts Direct exhaust with silencer box: D side exhaust Direct exhaust with silencer box: U side exhaust P65 enclosure SB SD Note 1) 12 12 stations SU Note 1) W U D U D Note) Combination of [C ] and [S ] is not possible.
Mounting Bolt for CQM/Without Auto Switch Model C D Mounting bolt Model C D Mounting bolt Model C D Mounting bolt CQMB12-5 -10 -15 -20 -25 -30 CQMB16-5 -10 -15 -20 -25 -30 CQMB20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 CQMB40-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -75 -100 CQMB50-10 -15 -20 -25 -30 -35 -40 -45 -50 -75 -100 CQMB25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 CQMB32-5 -10 -15 -20 -25
2-G F E 2-H C D A B Side support B MY-SB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.
2-G F E 2-H C D A B Side support B MY-SB 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.
(mm) Hw 23 Ht 15 Hv 10.5 Auto switch model D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C Note 2) For 25 stroke, 2 magnets for auto switches are installed in the housing. Note 1) The dimensions show D-E7A and D-E80A.
-X 20Hv Data Proper Auto Switch Mounting Position Solid state switch Bore size (mm) 2-color indication solid state switch Reed switch D-A9 D-A9V D-M9 D-M9V D-F8 D-F9W A B Hv D-F9WV A B C A B Hv A B C A B Hv A B Hv A B C 36 25 16 36 25 15 32 21 20 32 21 17.5 18 7 25 32 21 20 32 21 17.5 8 Auto Switch Mounting Stroke for 8 Stroke (mm) Note Applicable auto switch Mounting condition Piping direction
Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
Applicable bore size (mm) B C D d H Dd9 L d Part no. 0.040 0.076 0.040 0.076 0.050 0.093 14 0.050 0.093 0.040 0.076 0.040 0.076 0.040 0.076 CD-G02 CD-G25 CD-G03 CD-G04 NT-02 NT-03 NT-G04 20 25 32 40 20 25, 32 40 21 25.6 41.6 7.6 9.6 9.6 IY-G02 IY-G03 IY-G04 M8 x 1.25 5 6 8 20 25, 32 40 13 17 19 15.0 19.6 21.9 12.5 16.5 18 8 10 12 8 10 10 43.4 48 59.4 71.4 7.6 9.6 11.5 13.4 M10 x 1.25 M14
SUP/EXH block assembly mounting position U D side D B U side 2 to 10 stations OMRON Corp.: SYSBUS Wire System C SHARP Corp.: Satellite I/O Link System D Matsushita Electric Works, Ltd.: MEWNET-F System E NKE Corp.: Uni-wire System (16 points output) F1 2 to 15 stations Both sides Special specifications M SUP/EXH block assembly specifications When creating the special specifications, complete
8 12 16 20 D-A9 D-A9V 10 6 6 8.5 10 D-M9 D-F9W D-M9V D-F9WV 5.5 (4) 3 (2) 3 (3) 4 (3) 6 (4) Interference Note) Figures in parentheses are the case for D-M9, D-M9V switch types.
D-Y59BL 2 pcs. 25 15 D-Y69BL 1 pcs. D-Y7PL Solid state switch CJ1 Auto switches are mounted on the same side but in different grooves of the cylinder.
D-Y59BL 2 pcs. 25 15 D-Y69BL 1 pcs. D-Y7PL Solid state switch CJ1 Auto switches are mounted on the same side but in different grooves of the cylinder.