Lead wire length (m) Indicator light Direct mounting Load voltage Applicable load Rail mounting Pre-wire connector Wiring (Output) Special function Type Electrical entry 32 to 100 12 to 100 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equivalent) IC circuit 5V A96V A76H A96 Grommet A72H A73H 200 V A72 A73 A73C A93V A93 Reed switch Solid

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting double rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, flange, trunnion

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, MX, 40MM CM2 DBL-ROD AUTO-SW, 3.1766 lb

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting double rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, flange, trunnion

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, MX, 40MM CM2 DBL-ROD AUTO-SW, 2.2781 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, MX, 40MM CM2 DBL-ROD AUTO-SW, 3.01739 lb

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting double rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, flange, trunnion

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting double rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, flange, trunnion

Please consult with SMC regarding water resistant type with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93

Applicable models: D-A73, A73H, D-A93, A93V 2) Note however, that in the case of 2 color indicator type auto switches (D-A79W), if the wiring is reversed, the the switch will be in a normally ON condition.

However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12

Applicable models: D-A73, A73H, A73C, Z73, D-A93 1) If connections are reversed on a 2 wire type switch, the switch will not be damaged if protected by a protection circuit, but the switch will always stay in an ON state.

Note 3) ( ) in column W is the dimensions of D-A93.

Note 4) Figures in ( ) in the table W are D-A93. (mm) Operation Range 20 Bore size Auto switch model 10 6 16 9 25 12.5 32 14 D-A9, A9V D-M9, M9V D-M9W, M9WV 11 7 4 5 7 7 Since this is the average value at a normal temperature including hysteresis (tolerance 30%), it is not guaranteed.

Note 4) Figures in ( ) in the table W are D-A93.

For 10, 15, 20 CE2 Lead wire length (m) Load voltage Indicator light Pre-wire connector Special function Type Electrical entry Wiring (Output) ML2B Applicable load AC DC Auto switch model 0.5 (Nil) 3 (L) 5 (Z) 3-wire C J G5-S Reed switch Solid state switch Reed switch Solid state switch A96 5 V IC circuit Yes Yes Grommet (NPN equivalent) 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW 3-

Note 3) ( ) in column W is the dimensions of D-A93.

-wire (NPN) 5 V, 12 V M9NA*1 v v V v v IC circuit 3-wire (PNP) M9PA*1 v v V v v 2-wire 12 V M9BA*1 v v V v v With diagnostic output (2-color indicator) 4-wire (NPN) 5 V, 12 V F59F V V v v IC circuit Water-resistant (2-color indicator) Grommet Magnetic field resistant (2-color indicator) 2-wire (Non-polar) P4DW V V v Yes 3-wire (NPN equivalent) 5 V A96 V V IC circuit 100 V A93