Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 1/2, Normally Open, Closed: N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 30, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 60, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 3/4, Normally Open, Closed: N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 30, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 40, Type: Regulator Type, Pipe Thread: Rc, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 40, Type: Regulator Type, Pipe Thread: NPT, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 30, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 30, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 1/4, Normally Open, Closed: N.C., Normally Closed, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 60, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 3/4, Normally Open, Closed: N.C., Normally Closed, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 40, Type: Regulator Type, Pipe Thread: G, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 30, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 1/4, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

Body Size: 30, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 1/4, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Push-turn Locking Type, Manual

. -15No.EX-OMA1023 SI Unit Model Indication and How to Order EX600-S EC 3 SI unit Polarity of output Symbol Content Protocol 3 PNP (Negative common) Symbol Content 4 NPN (Positive common) EC EtherCAT Summary of Product parts No.

Directive and standards The standards to which the SI Unit conforms are listed in the certificate issued by the approval body and in the EC declaration of conformity. 1.4.1. Intended use The EX260-FPS1 is designed exclusively for use in a PROFIsafe system and fulfils the PROFINET guidelines as defined by PI (PNO).

Directive and standards The standards to which the module conforms are listed in the certificate issued by the approval body and in the EC declaration of conformity 2.4.1. Intended use The EX245-FPS1/2/3 module is designed exclusively for use in a PROFIsafe system and fulfils the PROFINET guidelines as defined by PI (PNO).

SI EC 2.4.1. SI PROFIsafe PIPNOPROFINET SI SI 4 SI SI EN60204 Part1 12 No.EX##-OMY0006CN 2.5. 2.5.1. www.smcworld.com) 2.5.2. PROFIsafe / PROFINET PROFIsafe PIPNO( www.profisafe.net) PROFIsafe I/O PROFIsafe 2.6. Table 2-1 SIL Safety integrity level IEC 61508 SIL 2, SIL 3 SILCL SIL claim limit EN 62061 SIL CL 3 Cat.

(Request):0106000C0001EC [CR][LF] (Response):0106000C0001EC [CR][LF] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 06 Function 06 Function 000C Address of specified register 000C Address of register to write 0001 Information written to 000Ch (Stop flag) 0001 Information of register to write EC LRC EC LRC 4.8 Explanation of function codes HRS090

(Request):0106000C0001EC [CR][LF] (Response):0106000C0001EC [CR][LF] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 06 Function 06 Function 000C Address of specified register 000C Address of register to write 0001 Information written to 000Ch (Stop flag) 0001 Information of register to write EC LRC EC LRC 4.8 Explanation of function codes HRSH

CE : EMC 2004/108/EC Low Voltage Directive 2006/95/EC UL : UL61010-1 SEMI : S2-0706, F47-0200 9.4.2 When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade and Industry (Foreign Exchange and Foreign Trade Control Law). 9-5 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http