SMC Corporation of America
Elite Part Number Search
Search Results "25A-ZSE20C-V-M-02-W"

size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46

50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.

Applicable model HRS0 -A -20-T-R Rated flow (50/60 Hz) Note 1),2) L/min 10 (0.35 MPa) /14 (0.35 MPa) Maximum flow rate (50/60 Hz) L/min 17 / 20 Pump Maximum pump head (50/60 Hz) m 70 Output W 610 Recommended earth leakage breaker capacity A 15 Cooling capacity Note 3) W The cooling capacity reduces approximately 300 W from the value in the catalog Note 1) The capacity at Thermo-chiller outlet

-02-08/AN200-2 Speed controller/Silencer 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 10 x 1 m) Speed controller/Silencer AS3301F-02-10/AN200-2 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 12 x 1 m) Speed controller/Silencer AS4001F-02-12/AN200-2 It is when the cylinder is

Grommet: G Conduit: C 300 V D D F Q F Q 280 300 VC Class H coil Broken line section C C G1/2 R R VDW VQ E E VX2 A H A H B B 2-P Port size 2-P Port size VX 2-M, thread depth N 2-M, thread depth N Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K K VN

Lead wire length symbols: 0.5 m Nil(Example) Y59B 3 m L (Example) Y59BL 5 m Z (Example) Y59BZ Z76 5 V IC circuit Reed switch Solid state switch Yes 100 V Z73 12 V Grommet Relay, PLC 24 V 2-wire 100 V or less No 5 V, 12 V Z80 IC circuit Y59A 3-wire (NPN) IC circuit 5 V, 12 V Y7P 3-wire (PNP) Y59B 2-wire 12 V Relay, PLC Yes Grommet 24 V 3-wire (NPN) Y7NW Diagnostic indication (2-color

Linearity within 1% (Full span) Hysteresis 0.5% (Full span) Repeatability 0.5% (Full span) ITV (Electro-pneumatic regulator) Mist separator (0.01 m or less) (0.3 m or less) High-speed response time 0.1sec Air Filter (5 m or less) IR (Precision regulator) W (Without load) 14-8-2 3 Compact Electro-pneumatic Regulator Series ITV0 How to Order F.R.L.

Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Applicable bore size 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) 20 to 63 80, 100 Perpendicular In-line In-line Indicator light Wiring (Output) Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) G59 V V v v 3-wire (PNP) M9PV M9P V V V v v G5P V V v v 5 V, 12 V

Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.

Stations 02 2 stations IN port direction ... ...

Tank capacity (l) Tc [s] = L W Obtain the tank capacity V. Select tank from table below.

Auto switch model 5 (Z) 1 (M) 3 (L) None (N) 0.5 (Nil) AC DC M9N M9P M9B H7C M9NW M9PW M9BW H7BA H7NF 3-wire (NPN) IC circuit 5 V, 12 V Grommet 3-wire (PNP) Solid state switch 12 V 2-wire Connector Relay, PLC 24 V 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 3-wire (PNP) Grommet 12 V 2-wire Water resistant (2-color indication) 5 V, 12 V IC circuit

YA-03 Joint YU-03 RS W M V T2 Joint Part No. 2-D through 2-O counterbore T1 B E J Applicable mounting bracket Bore size (mm) Weight (g) Joint part no.

RZQ Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL MI W S CEP1 CE1 Auto Switch Mounting Bracket Part No.

The exta volume enables for residual fluid in external piping to contain in the tank during mainatenance. 6.3 Option L [Large capacity tank] HRS-R Series 6-2 HRX-OM-X027 Chapter 6 OptionOptional Accessories 6.4 Option V [Stainless steel enclosure] 6.4.1 Option V [Stainless steel enclosure] With option V , the materials of enclosures are changed to stainless steel.

Electrical entry 3 Note) Compatible with ZX1-VJ324Mand ZX1-VJ314only. 5 6 V S R L LN LO M MN MO G H Connector (0.3 m) Connector (w/o lead wire) Without connector Connector (0.3 m) Connector (w/o lead wire) Without connector Grommet (0.3 m) Grommet (0.6 m) Note) In the case of ZX1-VJ114, M, MN and MO cannot be used.

type plug connector R Port P, E Port R Port P, E Port G : 300mm lead wire L : 300mm lead wire LZ: Lead wire w/ light & surge suppression M : With lead wire (Length: 300mm) H : 600mm lead wire LO : Without MZ: Lead wire w/light & surge suppression LOZ: W/out lead wire with light & surge suppression LO U : W/out lead wire with light & surge suppression for flat cable manifold MO: Without MOZ

Series: 25A-PFMB7, Flow Rate Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Out Specification: C (Out 1: NPN, Out 2: Analog 1 to 5 V), Lead Wire: W (Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber), Unit Specifications: M (SI Unit Only), Bracket: R (w/Bracket)

Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon

(Individual exhaust for Pilot valve) L LN Connector (0.3 m) Connector (W/o lead wire) LO Without connector M Connector (0.3 m) MN Connector (W/o lead wire) MO Without connector G Grommet (0.3 m) H Grommet (0.6 m) Rated voltage 1 3 100 VAC 110 VAC 5 24 VDC 6 12 VDC V Pilot valve DC: 1 W (With indicator light: 1.05 W) 24 VDC and 12 VDC are applicable to 0.45 W.