size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46
50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.
Applicable model HRS0 -A -20-T-R Rated flow (50/60 Hz) Note 1),2) L/min 10 (0.35 MPa) /14 (0.35 MPa) Maximum flow rate (50/60 Hz) L/min 17 / 20 Pump Maximum pump head (50/60 Hz) m 70 Output W 610 Recommended earth leakage breaker capacity A 15 Cooling capacity Note 3) W The cooling capacity reduces approximately 300 W from the value in the catalog Note 1) The capacity at Thermo-chiller outlet
-02-08/AN200-2 Speed controller/Silencer 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 10 x 1 m) Speed controller/Silencer AS3301F-02-10/AN200-2 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 12 x 1 m) Speed controller/Silencer AS4001F-02-12/AN200-2 It is when the cylinder is
Grommet: G Conduit: C 300 V D D F Q F Q 280 300 VC Class H coil Broken line section C C G1/2 R R VDW VQ E E VX2 A H A H B B 2-P Port size 2-P Port size VX 2-M, thread depth N 2-M, thread depth N Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K K VN
Lead wire length symbols: 0.5 m Nil(Example) Y59B 3 m L (Example) Y59BL 5 m Z (Example) Y59BZ Z76 5 V IC circuit Reed switch Solid state switch Yes 100 V Z73 12 V Grommet Relay, PLC 24 V 2-wire 100 V or less No 5 V, 12 V Z80 IC circuit Y59A 3-wire (NPN) IC circuit 5 V, 12 V Y7P 3-wire (PNP) Y59B 2-wire 12 V Relay, PLC Yes Grommet 24 V 3-wire (NPN) Y7NW Diagnostic indication (2-color
Linearity within 1% (Full span) Hysteresis 0.5% (Full span) Repeatability 0.5% (Full span) ITV (Electro-pneumatic regulator) Mist separator (0.01 m or less) (0.3 m or less) High-speed response time 0.1sec Air Filter (5 m or less) IR (Precision regulator) W (Without load) 14-8-2 3 Compact Electro-pneumatic Regulator Series ITV0 How to Order F.R.L.
Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Applicable bore size 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) 20 to 63 80, 100 Perpendicular In-line In-line Indicator light Wiring (Output) Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) G59 V V v v 3-wire (PNP) M9PV M9P V V V v v G5P V V v v 5 V, 12 V
Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.
Stations 02 2 stations IN port direction ... ...
Tank capacity (l) Tc [s] = L W Obtain the tank capacity V. Select tank from table below.
Auto switch model 5 (Z) 1 (M) 3 (L) None (N) 0.5 (Nil) AC DC M9N M9P M9B H7C M9NW M9PW M9BW H7BA H7NF 3-wire (NPN) IC circuit 5 V, 12 V Grommet 3-wire (PNP) Solid state switch 12 V 2-wire Connector Relay, PLC 24 V 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 3-wire (PNP) Grommet 12 V 2-wire Water resistant (2-color indication) 5 V, 12 V IC circuit
YA-03 Joint YU-03 RS W M V T2 Joint Part No. 2-D through 2-O counterbore T1 B E J Applicable mounting bracket Bore size (mm) Weight (g) Joint part no.
RZQ
The exta volume enables for residual fluid in external piping to contain in the tank during mainatenance. 6.3 Option L [Large capacity tank] HRS-R Series 6-2 HRX-OM-X027 Chapter 6 OptionOptional Accessories 6.4 Option V [Stainless steel enclosure] 6.4.1 Option V [Stainless steel enclosure] With option V , the materials of enclosures are changed to stainless steel.
Electrical entry 3 Note) Compatible with ZX1-VJ324Mand ZX1-VJ314only. 5 6 V S R L LN LO M MN MO G H Connector (0.3 m) Connector (w/o lead wire) Without connector Connector (0.3 m) Connector (w/o lead wire) Without connector Grommet (0.3 m) Grommet (0.6 m) Note) In the case of ZX1-VJ114, M, MN and MO cannot be used.
type plug connector R Port P, E Port R Port P, E Port G : 300mm lead wire L : 300mm lead wire LZ: Lead wire w/ light & surge suppression M : With lead wire (Length: 300mm) H : 600mm lead wire LO : Without MZ: Lead wire w/light & surge suppression LOZ: W/out lead wire with light & surge suppression LO U : W/out lead wire with light & surge suppression for flat cable manifold MO: Without MOZ
Series: 25A-PFMB7, Flow Rate Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Out Specification: C (Out 1: NPN, Out 2: Analog 1 to 5 V), Lead Wire: W (Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber), Unit Specifications: M (SI Unit Only), Bracket: R (w/Bracket)
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon
(Individual exhaust for Pilot valve) L LN Connector (0.3 m) Connector (W/o lead wire) LO Without connector M Connector (0.3 m) MN Connector (W/o lead wire) MO Without connector G Grommet (0.3 m) H Grommet (0.6 m) Rated voltage 1 3 100 VAC 110 VAC 5 24 VDC 6 12 VDC V Pilot valve DC: 1 W (With indicator light: 1.05 W) 24 VDC and 12 VDC are applicable to 0.45 W.