size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46
types LXSH5 S SA F9N 1 Stroke Lead wire length (m) Contact Model Wiring/ Output type Symbol Without auto switch Nil F9N F9P F9G F9H F9GL F9HL F9B F9NL F9PL F9BL Number of auto/proximity switches None Yes (cable length 0.3m) Nil S Home position switch N.O.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
= St/To = 1000 mm/s Maximum speed Vmax = 1.5 Vm = 1500 mm/s RHC20 7J RHC MK(2) 100 Model selection by graph RS Q G 50 Load weight M = 1000 N Max. speed Vmax = 1500 mm/s RS H A Graph 1-1 RZQ 10 RHC80 MI W S 50 100 500 1000 2000 3000 Maximum speed Vmax (mm/s) CEP1 Graph (1)-2 Vertical Drive Supply Pressure 0.5 MPa Selection Example: 2 CE1 10 Operating conditions CE2 Vertical drive Graph (
(mm) Note) Effective area (mm2) Connection thread Rc Mounting plate thickness 7 mm or smaller Width across flat T (M) M Weight (g) Mounting hole L2 L1 Model H1 H2 KQG2E23-02 KQG2E04-01 KQG2E04-02 KQG2E06-01 KQG2E06-02 KQG2E06-03 KQG2E08-01 KQG2E08-02 KQG2E08-03 KQG2E10-02 KQG2E10-03 KQG2E12-03 KQG2E12-04 KQG2E16-03 KQG2E16-04 3.2 14.8 9.7 14.8 7 13.7 14.9 8.1 13.1 14.6 13 14.4 14.4 19.7 13.3
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 Read the operation manual completely before operation, and keep this manual where it can be referred to as necessary. 14) In locations where strong impacts or vibrations occur 15)
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30L IDG50L 0 m 40 1 m 39 3 m 38 5 m Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. 14-19-25 22 Series IDG Single Unit/Standard Dew Point 60C Specifications How to Order 03 B IDG 60 S Option Flow rate by size None (Standard) With
Symbol Description Nil None S Lead wire with M12 connector (Straight, 5 m) L Lead wire with M12 connector (Right-angled, 5 m) Unit specification Symbol Description Nil Unit selection function*1 M SI unit only*2 *1 Under the New Measurement Act, switches with the unit selection function are not permitted for use in Japan. *2 Fixed unit: MPa, kPa Options/Part Nos.
Inlet pressure 0.5 MPa Total stroke time (t) (1) Piping length SV1000: 1 m, SV2000/3000: 2 m, SV4000: 3 m Stroke (L) Speed d% d% Stroke (mm) Speed at the end Cylinder direction Vertical upward Stroke Speed controller Meter-out, Directly connected to cylinder, Needle fully open (2) Load ratio {(Load weight x 9.8) Theoretical output} x 100% Speed at the end (u) Time (s) SOL: ON(OFF) 1-2-6
Power dissipation (W): For AC , W=V/A cos. For DC, W=V/A (Note) cos (Note) cos shows power factor. w Surge voltage The surge voltage is a high voltage generated momentarily when cutting the power supply. e Hum sound The hum sound is a noise generated through repeated adsorption and releasing on an armature adsorption surface.
s2 acceleration, whichever is smaller. 4.9 m/s2 Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Weight Note 3) 410 g 470 g 650 g 1,100 g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W2/3.
(0.01 s increment), 0.1 to 1.0 s (0.1 s increment), 1 to 10 s (1 s increment) Select from 20 s, 30 s, 40 s, 50 s, 60 s Hysteresis 8 Variable Protection Short circuit protection Output type Voltage output: 1 to 5 V (0 to 10 V can be selected, only when the power supply voltage is 24 VDC) 10, Analogue outpour 9 Current output 4 to 20 mA Impedance Voltage output Output impedance approx.1 k Current
0 R/W (1000 ~ 3310) ISE71: 0x03E8 ~ 0x0C9E (1000 ~ 3231) Setting of OUT2 delay time at ON 0.01 s increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 ~ 0x1770 (0 ~ 6000) 1028 0x0404 0 R/W dtL2 (Delay time at OFF) U16 0 Y Setting of OUT2 delay time at OFF 0.01 s increment Settable values 0x0 ~ 0x0BB8 (0 ~ 3000) 1030 0x0406 0 R/W FiL (Digital filter) U16 0 Y Setting
(10003200) Setting of OUT1 delay time at ON 0.01 s increment 1017 0x03F9 0 R/W dtH1 (Delay time at ON) U16 0 Y Settable values 0x0 ~ 0x1770 (0 ~ 6000) 1018 0x03FA 0 R/W dtL1 (Delay time at OFF) U16 0 Y Setting of OUT1 delay time at OFF 0.01 s increment 0: HYS (Hysteresis) 1: Wind oUt2 (Selecting output mode) Setting of OUT2 output mode U8 0 Y 1020 0x03FC 0 R/W (Window comparator) 2: Err
S = 6mm 5. S = 15mm 4. S = 10mm 7. S = 27mm 5. S = 15mm 7. S = 27mm 10. S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1.
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
How to Order 100 TS0604 W Length per roll Color Tubing model Symbol Length Symbol Color Color Symbol 20 20 m roll B Black BU Blue Y Yellow G Green 100 100 m roll (Black and white only) W White R Red Made to Order (Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.) 100 m reel Metric size and Inch size except 16: Suffix
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked "" are produced upon receipt of order.