Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (with Rc-G Conversion Fitting Set], Option 1: MT (M + T), Option 2: Z (No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: w/Feet, w/o Rack Mounting Brackets
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Applicabe to DI Water Piping, Option 2: No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: Applicabe to DI Water Piping, Option 2: No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip
Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., Valve, Media (N.O.), 2 PORT VALVE, K84, 1800 lb
Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., Valve, Media (N.O.), 2 PORT VALVE, 1800 lb
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket:
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment), Port Size: 04 (TSJ1/2, Compression Fitting), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate PNP; Temperature: PNP; w/Temperature Sensor), Lead Wire: N (w/o Lead Wire with M8 Connector, 3 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C),
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: M (Applicabe to DI Water Piping), Option 2: Z (No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Magnet: D (Built-in), Mounting: E (Double End Mount), Bore Size: 106 (1 1/16"), Stroke: 1800 (18"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Support Guide, Long Stroke, ELECTRIC ACTUATOR, 0.00000 lb
SUPPORT GUIDE / CLEAN SERIES, ELECTRIC ACTUATOR, A06, 2.37 lb
CLEAN SERIES SUPPORT GUIDE, ELECTRIC ACTUATOR, A06, 3.22 lb
SUPPORT GUIDE / CLEAN SERIES, ELECTRIC ACTUATOR, 0.92 lb
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: M (Applicabe to DI Water Piping), Option 2: Z (No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip)
Magnet: None, Mounting: B (MX0, Basic), Bore Size: 400 (4"), Stroke: 1800 (18"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
Magnet: None, Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 1800 (18"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)