MANIFOLD BLOCK. J55. 620.00000 lb. 4/5 PORT SOLENOID VALVE.
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: EB (EtherNet/IPâ„¢, IO-Link Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: 7 Stations, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
Model: 10S6 (Side Ported), SI Unit: EB (EtherNet/IPâ„¢, IO-Link Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: 7 Stations, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)
"END PLATE, 4/5 PORT SOLENOID VALVE
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, N, "VALVE
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
Series VFS consists of 5 port pilot solenoid valves with metal seals and base mounted or body ported type manifolds. Base mounted manifolds are available in plug-in and non plug-in styles. Body ported manifolds are available with bar or separate type manifold bases. Port sizes range from 1/8 to 3/4 with Rc(PT), NPTF & G(PF) thread types available. Various options also available. Fluid: air
Series VFS consists of 5 port pilot solenoid valves with metal seals and base mounted or body ported type manifolds. Base mounted manifolds are available in plug-in and non plug-in styles. Body ported manifolds are available with bar or separate type manifold bases. Port sizes range from 1/8 to 3/4 with Rc(PT), NPTF & G(PF) thread types available. Various options also available. Fluid: air
Series VFS consists of 5 port pilot solenoid valves with metal seals and base mounted or body ported type manifolds. Base mounted manifolds are available in plug-in and non plug-in styles. Body ported manifolds are available with bar or separate type manifold bases. Port sizes range from 1/8 to 3/4 with Rc(PT), NPTF & G(PF) thread types available. Various options also available. Fluid: air
Series VFR consists of 5 port pilot solenoid valves with rubber seals and base mounted type manifolds, available in plug-in and non plug-in styles. Port sizes range from 1/8 to 1/2 with Rc(PT), NPTF & G(PF) thread types available. Various options also available. VFR4000, plug-in & non plug-in types, Maximum operating pressure: up to 0.9MPa, Ambient & fluid temperature: Max. 50°C, Manual override
Series VFS consists of 5 port pilot solenoid valves with metal seals and base mounted or body ported type manifolds. Base mounted manifolds are available in plug-in and non plug-in styles. Body ported manifolds are available with bar or separate type manifold bases. Port sizes range from 1/8 to 3/4 with Rc(PT), NPTF & G(PF) thread types available. Various options also available. Fluid: air
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: Q (DeviceNetâ„¢), Input Block Stations: 1 Station, Input Block Type, Common Spec: D (Negative Common, M12, 2 Inputs), Valve Stations: 10 Stations, P,E Port Location, SUP/EXH Assembly: G (Port Location U Side, External Pilot), A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail
Model: 10S3 (Side-Ported, Serial Interface), SI Unit Specification: Q (DeviceNetâ„¢), Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assembly: S (Internal Pilot/Built-in Silencer), A, B Port Size: N3 (ø5/32" One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: Q (DeviceNetâ„¢), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: 5 Stations, Valve Stations: 10 Stations, P,E Port, SUP/EXH Assembly: C (Port Location U Side, Internal Pilot, Built-in Silencer), A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: AA (Direct Mounting