and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB
monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB
and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB
Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, .55115 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage
Please contact us for the latest version.sales@ocaire.com, IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.12125 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA
Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.57686 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output
Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.57686 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output
Please contact us for the latest version.sales@ocaire.com, IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.4354 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA
Please contact us for the latest version.sales@ocaire.com, Operation Manual, IT2000 1/4 INCNPT VERSION, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, 1.44511 lb
Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.43432 lb
Please contact us for the latest version.sales@ocaire.com, IFW/PFW 1/4INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.22045 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VX3 BODY PT 1/8, VALVE, VX3 3-WAY MEDIA VALVE, DB, VX3 BODY PT 1/8, 1.10231 lb
Please contact us for the latest version.sales@ocaire.com, REGULATOR, AIRLINE EQUIPMENT, SR SS REGULATOR, DB, SR 1/4INCH STANDARD (PT), .00733 lb
The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available in MPa, kgf/cm², bar, PSI, and kPa units., Pressure range of 0.005 to 0.9MPa., Available port sizes 1/4 and 3/8., Mounting bracket option., Operation Manual, IT1000 1/4 INCNPT VERSION, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, 1.32277 lb
Please contact us for the latest version.sales@ocaire.com, Operation Manual, IT1000 1/4 INCNPT VERSION, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, 0.99208 lb
Please contact us for the latest version.sales@ocaire.com, Operation Manual, IT1000 1/4 INCNPT VERSION, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, 0.55115 lb
Please contact us for the latest version.sales@ocaire.com, Operation Manual, IT1000 1/4 INCNPT VERSION, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, 0.84081 lb
Please contact us for the latest version.sales@ocaire.com, Operation Manual, IT1000 1/4 INCNPT VERSION, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, 0.55115 lb
Please contact us for the latest version.sales@ocaire.com, Operation Manual, IT1000 1/4 INCNPT VERSION, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, 0.55115 lb
The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available in MPa, kgf/cm², bar, PSI, and kPa units., Pressure range of 0.005 to 0.9MPa., Available port sizes 1/4 and 3/8., Mounting bracket option., Operation Manual, IT1000 1/4 INCNPT VERSION, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, 2.20462 lb