D (Derivative action)This function detects the changing speed (time derivative) of command signal and load, thereby improving the quick responding performance of the control and correction. The variable range of derivative action time is 0 to 2sec.
Mounting/ Piping 100 2d D L 1 = Mandrel 5 2. Specific Product Precautions (2) (3) Check the model, type and size before installation. Also, confirm that there are no scratches, gouges or cracks on the product. (4) When connecting the tubing, take pressure or possible changes to the tubing length into account, and allow a sufficient margin.
Correspondence between output data and valve manifold : Output numbers are assigned to stations from side D to U of manifold in order. (See manual of each valve manifold for the directions of side D and U) : Standard manifold is wired in double. Output numbers are assigned to side A and B alternatively. In case of single solenoid valve, output on side B is free.
10 15 F CDJP D 10 15 F 90 S With Auto Switch Number of auto switches Action Air cylinder with auto switch S 2 1 Mounting Bore Size * 5 stroke: S type only With auto switch 6 10 15 6mm 10mm 15mm Symbol Mounting Standard B F L D T Basic Flange Foot Clevis Trunnion Applicable Auto Switches Length of lead wire (m) 0.5 () Load voltage Wiring (Output) Auto switch model No.
Applicable tubing O.D. d ASS Model AS231FE-01-04SK 12.7 17.5 9.3 13.1 24.9 4 9.3 26 31.8 ASR Applicable tubing O.D. d AS231FE-01-06SK 12 R 1/8 12 13.5 22.9 10.9 14 26.9 6 11.6 27 37.2 44.9 49.9 48.9 14.2 53.9 (Hexagon width across flats) AS231FE-01-08SK 18.5 28.2 12.9 16.2 30.9 8 15.2 29 41.7 ASF (Hexagon width across flats) AS231FE-02-04SK 16 21.9 10.9 16.2 30.6 4 10.4 36 40.1 AS231FE-02
E GS G Grommet terminal Grommet with surge voltage suppressor Grommet EZ T TZ D DZ Grommet terminal with light/surge voltage suppressor Conduit terminal Conduit terminal with light/surge voltage suppressor DIN terminal DIN terminal with light/surge voltage suppressor CE-compliant Symbol Valve size 1 Valve size 2 to 9 Electrical entry D DIN terminal DIN terminal with light/surge voltage suppressor
Mandrel Here, : Deformation ration (%) d: Tube diameter (mm) L: Measured length (mm) D: Mandrel diameter (mm) (Twice against the minimum bending radius) Handling of One-touch Fittings Test temperature: 20 5C Relative humidity: 65 5%. Caution 3. Applicable for general industry water. Please consult with SMC if using other fluids.
Push-locking slotted type [D] Disconnection To remove the socket from the connector, pull out lead wire while depressing the hook of the socket with a fine screwdriver. If the socket is to be re-used, reposition the hook again. Caution Gently operate locking manual override types B, D using a small screw driver.
4 60 PSI (4kg|/cm') 6 90 PSI (6kglicm") lnput Current 0-4-20mADC(standard) . l 1 5 m A D C ' 2 2 1 0 m A D C ' 3 5 2 5 m A D C *4 10 50 mADC ' Special Order o ,,' Ogeration'/ Construction Model MmOO(Lever type) Single acting, Normal operation When the input current increass, the armature witt be subjected to a clockwise torque, pushing the flapper lever to the teft.
Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
CEP1 Action D B T CE1 CE2 Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
Note Weight Bracket LFE-1-D Tapping screw for LFE1 (3 x 10), 4 pcs. Approx. 45 g LFE-2-D Tapping screw for LFE2 (3 x 10), 4 pcs. Approx. 70 g LFE-3-D Tapping screw for LFE3 (3 x 10), 4 pcs. Approx. 70 g 3
NBR FKM Pressure range 0 to 7 MPa Rc G (ISO1179-1) NPT NPTF 3/8 1/2 3/4 1 Nil G N T Y u Pilot valve o Electrical entry T: Conduit terminal D: DIN terminal (Pitch between the terminals: 11 mm) W: M12 connector (4-pin type) Note 2) V: M12 connector (5-pin type) Note 3) DO: DIN terminal without connector Note 1) V116 i Rated voltage 1 2 3 4 5 6 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC [115
1 4 1 2 D DIN terminal 1 2 G Grommet (Lead wire length 300 mm) Grommet (Lead wire length 600 mm) DIN terminal DIN terminal (Without connector) Nil Without sub-plate H D DO 2 01 1 8 1 8 Base mounted 02 1 4 1 4 Caution Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.
Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material). 14-2-63 Series AL10 to 60 Dimensions AL10 AL20 L D Bracket (Option) G F Port size K M A Port size C B R C J H OUT OUT IN OUT OUT IN B R P Min. clearance for maintenance Min. clearance for maintenance A AL50/60 AL30/40 L D D L Port size Bracket (Option) Bracket (Option) G F G F Port size M K M K E J C B R
100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
.0.8m) J L K [200VAC specification] [200VAC specification] Terminal block Power cable outlet(17) H P N M [100VAC specification] Power cable(Length:approx.1.9m) measure mm Model Port size A B C D E F G H J K L M N P Q IDF1E Rc3/8 69 101 270 32 21 330 IDF2E Rc3/8 51 232 138 24 327 IDF3E Rc3/8 473 67 304 33 73 31 36 154 21 330 226 410 413 125 240 15 38 150 IDF4E / IDF6E / IDF8E, IDF11E A B
IDF Series 6-1 Specifications 6 1 IDX-OM-W025 Air Dryer 6 References 6-3 Dimentions IDF22E, IDF37E AIR OUTLET PORT SIZE AIR INLET PORT SIZE B A E D G SWITCH WITH LAMP EVAPORATION THERMOMETER DRAFT BALL VALVE AIR OUTLET F VENTILATION VENTILATION C TERMINAL BLOCK DRAIN TUBE (O.D.10) (820) K L P J H N M 413 POWER SUPPLY ENTRY( 17) [OTHER SIDE] measure mm Model Port size A B C D E F G H J
Solenoid on side A 0 2 4 6 8 16 28 30