This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, 2J, NEW SY3000 MFLD,NO SIZE RATING, 0.66138 lb

Direct air operated, 2 and 3 port valve series VXA can be used with a wide variety of fluids. The manifold for the VXA21/22 series is available in a common SUP style or individual SUP style (for vacuum use). The VXA31/32 series manifold is individual ported. Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style

The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY5000 MFLD, 2J, NEW SY5000 MFLD,NO SIZE RATING, 1.51677 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, UM, NEW SY3000 MFLD, FITTING .77161 lb, .77161 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, 2J, NEW SY3000 MFLD,NO SIZE RATING, 1.39625 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, 1S, NEW SY3000 MFLD, OTHER SIZE, .93255 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, 1S, NEW SY3000 MFLD, OTHER SIZE, 1.70858 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, 2J, NEW SY3000 MFLD,NO SIZE RATING, .89397 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, UM, NEW SY3000 MFLD, FITTING .81350 lb, .81350 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY3000 MFLD, 1S, NEW SY3000 MFLD, OTHER SIZE, .77161 lb

Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: EW (with Unit Options E & W), 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve and Release

Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 3 (110 VAC (115 VAC) 50/60 Hz), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: Without