SMC Corporation of America
Elite Part Number Search
Search Results "LMU200-53"

SMC has improved product performance and reliability with the redesignedáSY series valve.á The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

SMC's CG5-S series is a stainless steel cylinder, perfect for use in wash down applications such as food processing machinery requiring intense cleaning.  The use of non-toxic additives allows confident use in equipment for foods, beverages and medical products, etc.  The CG5-S can be disassembled, allowing replacement of seals, which promotes an extended service life.  SMC provides plugs

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Sub plate port size: 1/4"; Flow rate characteristics: Cv 0.64

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Threaded port: 1/8" to 3/8". One touch fitting: 4mm, 6mm, 8mm, 5/32", 1/4", 5/16" ; Flow rate characteristics: Cv 0.49   

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Sub plate port size: 1/2" ; Flow rate characteristics: Cv 2.0

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Threaded port: 1/4", one touch fitting: 8mm, 10mm, 5/16", 3/8" ; Flow rate characteristics: Cv 0.93  

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Sub plate port size: 3/8"; Flow rate characteristics: Cv 1.1

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Threaded port: 1/4", 3/8", one touch fitting: 8mm, 10mm, 12mm, 5/16", 3/8"; Flow rate characteristics: Cv 1.7

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Threaded port: 1/8" to 3/8". One touch fitting: 4mm, 6mm, 8mm, 5/32", 1/4", 5/16" ; Flow rate characteristics: Cv 0.49   

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Threaded port: 1/4", one touch fitting: 8mm, 10mm, 5/16", 3/8" ; Flow rate characteristics: Cv 0.93  

Intrinsically safe SY valve is designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers. Threaded port: 1/4", 3/8", one touch fitting: 8mm, 10mm, 12mm, 5/16", 3/8"; Flow rate characteristics: Cv 1.7

The SX series unique design combines both solenoid assemblies (when using double solenoid 2/3 position) on the same side of the valve, opposite the ports, allowing for greater space savings and simplified wiring access. The SX series valves are available with numerous manifold options which allow for easier installation and improved operation., END PLATE ASSY, U SIDE, VALVE, SS5Y5 MANIFOLD

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa

Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa

Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa