Compact Cylinder/Standard Type: Double Acting, Single Rod Construction Series CQS 12, 16, 20, 25 Replacement Procedure is P.290 Basic style !5 !7 !6 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CQS. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) !5 !6 !7
Compact Cylinder/Non-rotating Rod Type: Double Acting, Single Rod Construction Series CQSK 12, 16, 20, 25 Replacement Procedure is P.290 Basic style With auto switch (built-in magnet) Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !1 !3 !2 !1 !3 !2
Compact Cylinder/Non-rotating Rod Type: Double Acting, Double Rod Series CQSKW Replacement Procedure is 12, 16 20, 25 P.290 Construction Basic style With auto switch (built-in magnet) !4 !7 !6 !5 !4 !7 !6 !5 12 12 !5 !4 !7 !6 !4 !7 !6 !5 SMC 16, 20, 25 16 !4 !7 !6 !5 SMC 20, 25 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CQSKW. *BLUE links will lead
Compact Cylinder/Anti-lateral Load Type Construction Series CQSS Replacement Procedure is 12, 16 20, 25 P.290 Basic style Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !5 !3 !4 With auto switch (built-in magnet) !5 !3 !4 !3 !5 !4 12, 16 20, 25 The
Compact Cylinder/Standard Type: Double Acting, Double Rod Series CQSW Replacement Procedure is 12, 16 20, 25 P.290 Construction Basic style Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !2 !3 !1 With auto switch (built-in magnet) !2 !3 !1 !2 !3 !1
Compact Cylinder/Plate Type: Double Acting, Single Rod Series CQU 20, 25, 32, 40 Construction !2 !0 o !3 i !1 The numbers are the same as the "Construction" of the CQU series catalog (CAT.ES20-198). *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) CQUB20-PS CQUB25-PS CQUB32-PS CQUB40-PS 20 25
Free Mount Cylinder/Double Acting, Single Rod Series CU 10, 16, 20, 25, 32 Construction With auto switch Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters 10 !5 !4 !6 !5 !4 !6 16 to 32 !5 !4 !6 !5 !4 !6 The numbers are the same as the "Construction"
Mini Free Mount Cylinder Series CUJ 4, 6, 8, 10 Replacement Procedure is P.289 Construction Double acting Single acting, spring return Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !2 !3 !1 !1 Without magnet Without magnet The numbers are the same
Free Mount Cylinder/Non-rotating Rod Type: Double Acting, Single Rod Series CUK 10, 16, 20, 25, 32 Construction With auto switch Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters 10 @1 @0 !9 @1 @0 !9 16 to 32 @1 @0 !9 @1 @0 !9 The numbers are the same
Free Mount Cylinder/Non-rotating Rod Type: Double Acting, Double Rod Series CUKW 10, 16, 20, 25, 32 Construction With auto switch 10 @2 @1 @0 @2 @1 @0 16 to 32 @2 @1 @0 @2 @1 @0 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CUKW. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents
Free Mount Cylinder/Double Acting, Double Rod Series CUW 10, 16, 20, 25, 32 Construction With auto switch 10 !5 !6 !7 !5 !6 !7 16 to 32 !5 !6 !7 !6 !5 !7 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CUW. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) CUW10D-PS
Compact Cylinder with Air Cushion Construction Series RQ Replacement Procedure is 20, 25, 32, 40 50, 63, 80, 100 P.290 20 to 40 50 to 100 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !7 !8 !6 !7 !8 !6 A part A part !4 !3 !2 !5 Details of A part
Free Mount Cylinder for Vacuum Series ZCUK Construction With auto switch Cap piping, male thread: ZC(D)UKC 10 @0 !9 !8 @1 @0 !9 !8 @1 16 to 32 @0 !9 !8 @1 @0 !9 !8 @1 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series ZCUK. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents Bore
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Type: A [Servo Motor (24 VDC)], Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 250mm, Motor Option: B (w/Lock), Vacuum Port: Left, Positioning Pin Hole: K (Body Bottom, 2 Locations)
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 32, Motor Type: A [Servo Motor (24 VDC)], Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 250mm, Motor Option: B (w/Lock), Vacuum Port: Left, Positioning Pin Hole: K (Body Bottom, 2 Locations)
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 40, Motor Type: A [Servo Motor (24 VDC)], Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 250mm, Motor Option: B (w/Lock), Vacuum Port: Left, Positioning Pin Hole: K (Body Bottom, 2 Locations)
Piping: 1 (Bottom Direction), Body Color: BU (Dark Blue), Piping Type: Rc, Connection Size: H07 (Inch Size One-touch Fitting, ΓΈ1/4"), Nozzle: 11 (High Efficiency Nozzle, KNH-R02-100)
Suitable for applications where copper free specifications are required, the in.?FGin. series can also be used in areas where wash down could degrade standard flow controls, such as food and packaging. This series is designed to offer the maximum control by increasing the number of turns of the needle to 10. The body and adjustment are made of high impact white resin for a clean look. This
Suitable for applications where copper free specifications are required, the in. FGin. series can also be used in areas where wash down could degrade standard flow controls, such as food and packaging. This series is designed to offer the maximum control by increasing the number of turns of the needle to 10. The body and adjustment are made of high impact white resin for a clean look. This
Suitable for applications where copper free specifications are required, the in. FGin. series can also be used in areas where wash down could degrade standard flow controls, such as food and packaging. This series is designed to offer the maximum control by increasing the number of turns of the needle to 10. The body and adjustment are made of high impact white resin for a clean look. This