SMC Corporation of America
Elite Part Number Search
Search Results "11-CDM2B20-100AZ"

Magnet: Built-in, Type: Pneumatic, Mounting: Axial Foot, Bore: 32mm, Port Thread: Rc, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Leadwire or Prewired Connector: 3m, Number: 3 pcs.

Magnet: Built-in, Type: Pneumatic, Mounting: Integral Clevis, Bore: 40mm, Port Thread: NPT, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Leadwire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Double Clevis, Bore: 32mm, Port Thread: Rc, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -

Magnet: None, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 40mm, Port Thread: NPT, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: Pivot Bracket not assembled, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Integral Clevis, Bore: 20mm, Port Thread: NPT, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: Pivot Bracket not assembled, Rod End Bracket: -, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Rod Trunnion, Bore: 32mm, Port Thread: Rc, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Leadwire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Double Clevis, Bore: 40mm, Port Thread: Rc, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: -, Leadwire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Boss-Cut, Basic, Bore: 25mm, Port Thread: Rc, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Leadwire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Pneumatic, Mounting: Axial Foot, Bore: 25mm, Port Thread: Rc, Stroke: 100mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Leadwire or Prewired Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Environment, Applications: Clean Room, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The

Magnet: Built-in Magnet, Series: Standard, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Port Thread: Rc, Stroke A: 100mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: 0 to 25mm, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired Connector

Magnet: None, Series: Standard, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke A: 100mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: 0 to 25mm, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (

Magnet: Built-in Magnet, Series: Standard, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 40mm, Port Thread: Rc, Stroke A: 100mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: 0 to 25mm, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired Connector

Magnet: Built-in Magnet, Series: Standard, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 40mm, Port Thread: Rc, Stroke A: 100mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: 0 to 25mm, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired

Magnet: Built-in Magnet, Series: Standard, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 40mm, Port Thread: Rc, Stroke A: 100mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: 0 to 25mm, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired Connector

Magnet: Built-in Magnet, Series: Standard, Mounting: Basic, Tube Material: Aluminum Tube, Bore Size: 80mm, Port Thread: Rc, Stroke A: 100mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: 0 to 25mm, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: No Switch, Lead Wire or Prewired Connector

Content 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.

No.EX-OMV0023-A PRODUCT NAME SI unit for Ethernet POWERLINK MODEL / Series / Product Number EX260 Series Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 10 Installation 10 Wiring 11 LED Indication and Settings 15 Configuration 17 Troubleshooting and Maintenance 21 Specifications 26 Specifications 26 Dimensions

Report fault by diagnostics, show on diagnostic LED, and inhibit turn on. 11 Reverse supply protection External installation error Polarity diode No function and no supply to valves. In addition: The device goes into the Fail-safe state if it detects a fault. In Fail-safe state the output is "Off".

There are differences in the displayed values when using more than Refer to Trouble No.11 one product. The display accuracy Refer to Trouble No.12 does not meet the specifications. Applied voltage does Refer to Trouble No.8 not match with the displayed pressure value. The Display Refer to Trouble No.13 measurement unit cannot be changed. Buttons do not work.