This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, NON LUBE,AUTO-SW, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, PE, 63MM CA1 DBL-ACT AUTO-SW, 19.18021 lb
MEmax is the allowable moment for V. 3 = ME/MEmax 3: Dynamic moment Calculation example z Mounting on horizontal wall [1] Operating Conditions CY1SG25-600 Wa: Connection plate t = 10 (1.5 kg) Cylinder: CY1SG25-600 Cushion: Shock absorber Mounting: Horizontal wall mounting Speed: Va = 250 [mm/s] Wc: Rod L = 50 (0.5 kg) Wd: Workpiece (2.5 kg) [2] Load Blocking Wb: Arm L = 105 (1.0 kg) A = 33
Calculation example 7 Mounting on horizontal wall [1] Operating Conditions CY1SG25-600 Wa: Connection plate t = 10 (1.5 kg) Cylinder: CY1SG25-600 Cushion: Shock absorber Mounting: Horizontal wall mounting Speed: Va = 250 [mm/s] Wc: Rod L = 50 (0.5 kg) [2] Load Blocking Wd: Workpiece (2.5 kg) A = 33 50 Wb: Arm L = 105 (1.0 kg) 5 0 Z X Mass and center of gravity of the load 25 Center of gravity