(different sides, same side) 15 25 Y7P(V) 1pc. D-Y7NW(V), Y7PW(V), 2pcs. (different sides, same side) Solid state switch 20 25 Y7BW(V) 1pc. 2pcs. (different sides, same side) 20 30 D-Y7BAL 1pc. Center trunnion is not included.
12 V V 12-2 12-1 1. 1 2 2. 3.
Table(2) Rated Voltage-Electrical Entry-Electrical Option PAX Table(1) Connection Size and Applicable Model Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G C D, T G, C T PB S L, Z S L, Z S Note ) Connection Applicable model VXP2130-02 VXP2130-03,VXP2140-03 VXP2130-04,VXP2140-04 VXP2150-06
In actual application, only one color is displayed at a time. Abnormal conditions can be detected at a glance!
conduit 3-wire (NPN) Solid state auto switch G39C G39 2-wire K39C K39 12 V M9NW V V V v v G59W V V v v 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) Relay, PLC Yes 3-wire (PNP) M9PW V V V v v G5PW V V v v 2-wire 12 V M9BW V V V v v 24 V K59W V V v v Grommet 3-wire (NPN) 5 V, 12 V M9NA** v v V v v 3-wire (PNP) M9PA** v v V v v Water resistant (2
12 V 12 V IC circuit Relay, PLC 5 V, 12 V Diagnostic indication (2-color indicator) 24 V Yes Grommet 12 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PA1 M9PAV1 M9BA1 M9BAV1 12 V 3-wire (NPN equivalent) Grommet 24 V A96 A96V 5 V IC circuit Yes A93V2 A93 A90 IC circuit 100 V Relay, PLC 2-wire 12 V A90V No 100 V or less 1Water resistant type auto switches can be mounted
12 V 3-wire (PNP) M9PV M9P 2-wire 12 V M9BV M9B 3-wire (NPN) 5 V, 12 V M9NWV M9NW IC circuit 3-wire (PNP) M9PWV M9PW 2-wire 12 V M9BWV M9BW Diagnostic indication (2-color indicator) Relay, PLC 24 V Grommet Yes 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 IC circuit 3-wire (PNP) M9PAV1 M9PA1 2-wire 12 V M9BAV1 M9BA1 Water resistant (2-color indicator) Grommet Yes 3-wire (Equiv. to NPN) 5 V A96V
06 to 08 AL-197H-V 10 to 12 FKM-70 or EPDM-70 AL-198H-V Phosphoric ester 16 AL-199H-V 20 to 24 AL-200H-V 28 to 32 AL-201H-V Note) The material of seals (AL-196H-V to AL-201H-V) is EPDM-70.
() -27-67 NPN2 PNP2 -43 NPN PNP NPN PNP NPN PNP DC(+) -27 27 27 27 NPN 2 Max.30 V80 mA 1 V OUT1(NPN) DC12 24 V OUT2(NPN) DC(-) -43 43 43 43 NPN 1 + PNP 1 Max.30 V(NPN)80 mA 1 V NPN PNP DC(+) OUT1(NPN) DC12 24 V OUT2(PNP) DC(-) DC(+) OUT1(PNP) -65 65 65 65 PNP 1 Max.80 mA DC12 24 V N.C.
Applicable pad 4020W/5020W/6020W/8020W Applicable pad 3507W/4010W/5010W/6010W Applicable pad 4030W/5030W/6030W/8030W A-A A-A A-A (5) (5) (5) 14.8 8.8 6 1.5 A A A A A A 2 0.8 2 3.5 4 4 15 15 30 3 5 5 3 5 3 0.8 0.8 8.4 12.8 20.4 Note) R part has to be smooth with no corners.
Use a contact protection box.
P P For the release valve, select a 2/3 port valve with a low vacuum specification. Also, use a needle valve to regulate the release flow rate. During the adsorption and transfer of a workpiece, verification of the vacuum switch is recommended. In addition, visually verify the vacuum gauge when handling a heavy or a hazardous item.
P P For the release valve, select a 2/3 port valve with a low vacuum specification. Also, use a needle valve to regulate the release flow rate. During the adsorption and transfer of a workpiece, verification of the vacuum switch is recommended. In addition, visually verify the vacuum gauge when handling a heavy or a hazardous item.
P P For the release valve, select a 2/3 port valve with a low vacuum specification. Also, use a needle valve to regulate the release flow rate. During the adsorption and transfer of a workpiece, verification of the vacuum switch is recommended. In addition, visually verify the vacuum gauge when handling a heavy or a hazardous item.
12 V 12 V Relay, PLC IC circuit 5 V, 12 V 12 V Diagnostic indication (2-color indicator) 24 V Yes Grommet Water resistant (2-color indicator) IC circuit 5 V, 12 V M9PA1 M9PAV1 M9BA1 M9BAV1 12 V 3-wire (NPN equivalent) Grommet 24 V A96V A96 5 V IC circuit Yes A93V2 A93 A90 100 V IC circuit Relay, PLC 2-wire 12 V A90V No 100 V or less 1 Water resistant type auto switches can be
Table (1) Electrical entry/Light/Surge Voltage Suppressor With light/surge voltage supressor Z Without light/surge voltage suppressor Nil Electrical entry With surge voltage suppressor S Voltage T D W DO T D W DO V V AC V Note) V V V DC V Note) If a AC specification without DIN Terminal (DO) is selected, always use a DIN connector with surge voltage suppressor as the connector. 378 Coolant
For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that cannot vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
2-wire 12 V Water resistant (2-color display) *Solid state switches marked with a symbol are produced upon receipt of order.
G A S K E T C O N S T R U C T I O N A g a s k e t m a d e o f s t a i n l e s s s h e e t c o v e r e d w i t h l a m i n a t e d N B R o n b o t h s i d e s i s s e a t e d o n t h e chamfer of a female thread to materialize a perfect sealing construction irrespective of the difference in thread diameters due to the difference in the types of female threads, variation in tolerance, difference
Description 1 Power supply (24 VDC) 3 Power supply (0 V) 4 Input NOTE Be sure to fit a seal cap on any unused connectors of the input block. IP67 is maintained by using the seal cap.