Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: High pump head specification
Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: Rc, Optional specifications: High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: High pump head specification
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: Without auto
Body Size: 50, Thread: Rc, Port: 3/4, Option: Standard, Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 3/8, Option: D + M, Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 3/8, Option: D [Float Type Auto Drain (N.O.)], Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 25, Thread: Rc, Port: 1/4, Option: D [Float Type Auto Drain (N.O.)], Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 20, Thread: G, Port: 1/4, Option: C [Float Type Auto Drain (N.C.)], Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 1/2, Option: C [Float Type Auto Drain (N.C.)], Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 3/4, Option: D [Float Type Auto Drain (N.O.)], Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 3/8, Option: Standard, Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 3/4, Option: D + G, Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 3/8, Option: Round Pressure Gauge w/Limit Indicator, Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 50, Thread: Rc, Port: 3/4, Option: D + E, Attachment: T Spacer, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Type: Pressure Switch, Fluid Type: Air / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: PNP Open Collector / Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings, Plumbing Thread Type: -, Plumbing Thread Nominal: -, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Type: Positive
Type: Pressure Switch, Fluid Type: Air / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: PNP Open Collector / Analog, Analog Output Specification: Voltage, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Type: Positive Pressure
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Stroke: 100mm, Material: Steel, Ambient & Fluid Temp: T [-5 ~ 100°C (High Temp)], Pressure Gauge & Air Conn.: NPT
Stroke: 200mm, Material: Steel, Ambient & Fluid Temp: T [-5 ~ 100°C (High Temp)], Pressure Gauge & Air Conn.: NPT