SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20BF-L-P-N01-WA2"

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

PSE56PSE56--28 Applicable Liquid or gas that will not corrode stainless steel 316L Power supply voltage 12 to 24 VDC10%, ripple (p-p) 10% or less (Protected against inverse connection) Current consumption 10 mA or less Analogue output: 1 to 5 VDC Analogue output: 4 to 20mA (with rated pressure range) 0.6 to 1 VDC (with extension analogue output range) (with rated pressure range) Output specification

PSE540(A) PSE541(A) PSE543(A) Rated pressure range 0 to 1 MPa 0 to -101 kPa -100 to 100 kPa Extension analog output range -0.1 to 0 MPa 10.1 to 0 kPa Withstand pressure 1.5 MPa 500 kPa Applicable Air, inert gases and incombustible gases Power supply voltage 12 to 24 VDC10%, ripple (p-p) 10% or less (Protected against inverse connection) Current consumption 15 mA or less Analog output: 1 to

3 EA EA y A A P P r q B EB B !4 EB !7 !1 !2 t Component Parts Aluminum alloy NBR Note No. !0 Description Material No. PBT ADC Material Note q Description Black zinc chromated Metallic plated Pilot body Body Piston guide B Valve Metallic plated !1 !2 w e Return spring Cushion Cushion Valve spring Return spring Piston B Head cover r Stainless steel Spool/sleeve Stainless steel ZDC !

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

min 0.525 L/min 150 L/min 2100 L/min () CO2 0.25 L/min 0.512.5 L/min 125 L/min 250 L/min N2Ar 0.210.5 L/min 1 0.526.3 L/min 152.5 L/min 2105 L/min 2 CO2 0.25.2 L/min 0.513.1 L/min 126.2 L/min 252 L/min N2Ar 010.5 L/min 1 026.3 L/min 052.5 L/min 0105 L/min 2 CO2 05.2 L/min 013.1 L/min 026.2 L/min 052 L/min / 0.01 L/min 0.1 L/min 0.1 L/min 0.1 L/min / 3 09 L / 1 L 0.1 L/Pulse 0.1 L/

Port size Instruction manual Symbol Description Flow rate range 10 With instruction manual (Leaflet: Japanese and English) None Nil N 25 50 11 01 02 N01 N02 F01 F02 C4 C6 C8 N7 Rc1/8 Rc1/4 NPT1/8 NPT1/4 G1/8 G1/4 Unit specification With unit switching function M Nil Fixed SI unit Note) Note) Fixed unit: Real-time flow rate: l/min Accumulated flow: l 4 (5/32") one-touch fitting 6 one-touch

Option: Pressure gauge G15-10-01 How to Order NARM2000-4A2-N01G G15 P10 01 Symbol Units Nil MPa P PSI Common IN Individual IN IN M5 x 0.8 .39 (10) Max. pressure indication 10 150PSI (1.0MPa) .59 (15) IN OUT OUT *Pressure gauge for 30psig (0.2MPa) is not available.

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8)