SMC Corporation of America
Elite Part Number Search
Search Results "ZA1071-J15L-B-M2"

A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 17 (25) 32 5.5 9 7 11 10 4 30.5 33 33.5 25 (34) 24 (33) 20 (27) 21 (30) 23 (32) 19.5 (28.5) 40 10 13.5 35 37.5 38

Diaphragm B moves to the right, and at the same time diaphragm A also moves to the right Air exhaust port (AIR EXH) Switching valve Air supply port (AIR SUP) Pilot valve B Pilot valve A Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Shaft Suction port (FLUID IN) Diaphragm A Diaphragm B Drive chamber A Drive chamber B Control unit pushing pilot valve A. 3.

8370: JIS B 9960-1:-((1:) JIS B 8433-1:2007--1 *2) 1. 2. 3. a. b. c. 4. a. b.

JIS B 8370: JIS B 8361: JIS B 9960-1: -((1 :) JIS B 8433-1993: *2) : : : 1 2. 3. 1. 2. 3. 4. 2 2 - No.ZB-OM00301 3 1 1 *3) 1 1 () () () 3 - No.ZB-OM00301 () () 4 - No.ZB-OM00301 () * JIS B 8392-1 2.4.32.6.3 () 5 - No.ZB-OM00301 * F.G.

Inversion Traveling direction of cylinder Rod extending Rod retracting A-phase pulse B-phase pulse Count In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of approximately 90 phase difference. In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference.

Description Material Note 1 Body (R, L) Aluminum alloy (Black hard anodized) XT661-2A, 3A w 2 Body M Aluminum alloy (Black hard anodized) 741 XT661 Series Construction [Bernoulli Type] Size: 40 Size: 60 Size: 80, 100 A-A A-A A A q w w i u y t e e A B i A B r A A q A-A B-B t y u q u y t e w r r Size: 120, 150 B-B A-A A B B q r e w t y u i r C-C C C r A Guide assembly Component Parts A-A o

(Except cushion seal) Cushion ring B Rolled steel Zinc chromated Cushion valve Rolled steel Electroless nickel plated Rod seal SKY-36 SKY-36 SKY-40 @5 @6 NBR Spacer A Rolled steel Zinc chromated Piston seal RPS-125 RPS-140 RPS-160 Spacer B Rolled steel Zinc chromated Replacement Parts (Seal kits) Air releasing valve B Rolled steel Zinc chromated Air releasing valve A Chrome-molybdenum steel

Nil F N T A B Rc G NPT NPTF None With bracket (VN-16) is valve size NBR seals FKM seals Note 1) Valve size 1 comes with VN1A16 (with thread).

Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102 psi (0.7 MPa). 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4.

How to Calculate the Set Value A = Max. pressure value in auto preset mode B = Tentative min. pressure value in auto preset mode P1 = A (A B)/4 P2 = B + (A B)/4 Manual adjustment is possible after finishing in the auto preset mode. Ex.) When an error count (number of the failure predict) (EC) is set to be 3.

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.

When pilot valve B is pushed, the air which was acting upon the switching valve is exhausted, and drive chamber B once again switches to a supply state. A continuous reciprocal motion is generated by this repetition. 1. When air enters drive chamber B, the fluid in pump chamber B is forced out, and at the same time Drive unit fluid is sucked into pump chamber A. 2.

At this time, magnet B goes out of the movement range of auto switch B, causing auto switch B to turn OFF. Furthermore, the piston moves to the right, causing magnet A to enter the movement range of auto switch A. As a result, auto switch A turns ON.

P P Model/Valve Specifications Cv converted C [dm 3/(sbar)] b Cv Water, Oil Air Flow characteristics Max. operating pressure differential (MPa) Orifice size (mm) Model Proof pressure (MPa) Max. system pressure (MPa) Weight (g) Port size Av x 10-6 (m2) VXA3114 VXA3124 VXA3134 VXA3114 VXA3124 VXA3224 VXA3134 VXA3234 VXA3244 VXA3224 VXA3234 VXA3244 0.08 0.15 0.20 0.08 0.15 0.17 0.20 0.27 0.38

Model of Switch spacer BMY3-016 33 - Auto switch operation principle Fig. (14) Auto switch operation principle In the diagram above, auto switch B is ON. When pressure is applied from A, the piston moves to B, causing the shaft to rotate clockwise. At this time, magnet B goes out of the movement range of auto switch B, causing auto switch B to turn OFF.

E: Emitter C: Collector B: Base B: Base Load Electrical appliance connected to the output, e.g. relay, solenoid, etc. E: Emitter C: Collector Fig.2 NPN type Fig.3 PNP type Operating humidity range Humidity range for proper operation of equipment. Load current Current flow through the electrical appliance once the output is energized.