Flat head watchmakers screwdriver 5 to 6 Switch mounting screw M2.5 x 4l Hysteresis Auto switch Switch operating position (ON) Switch return position (OFF) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Max. hysteresis (mm) Auto switch model D-F9BAL D-M9(V) Setting
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5 to 6 Switch mounting screw (M2.5 x 4l ) MHL2-10D 0.8 0.5 0.6 MHS MHL2-16D Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6 mm to tighten the auto switch set screw. Use a tightening torque of 0.05 to 0.1 Nm.
Flat head watchmakers screwdriver 5 to 6 Switch mounting screw M2.5 x 4l Auto switch Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6 mm to tighten the auto switch mounting screw. The tightening torque should be about 0.05 to 0.1 Nm.
Flat head watchmakers screw driver Switch mounting screw (M2.5 x 4l) Accessory Note) When tightening the auto switch mounting screw, use a watchmakers screw driver with a handle about 5 to 6mm in diameter. Also, tighten to a torque of approximately 0.05 to 0.1Nm (0.51 to 1.02kgfcm).
Slotted set screw (M2.5 x 4l) (included) Flat head watchmakers screwdriver Auto switch Auto switch Auto switch mounting surface Magnetic substances such as an iron plate should be separated at least 15mm away from auto switch mounting surface. Magnetic substances may cause unstable operation of the auto switch.
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal
D-M9N-746 D-M9P-746 D-M9B-746 0.5 8 8 7 Lead wire length m Auto Switch Internal Circuit 3 41 41 38 5 68 68 63 MHZ D-M9N-746 MHF DC(+) Brown Auto Switch Dimensions Main circuit of switch Main circuit of switch Main circuit of switch MHL OUT Black D-M9N-746/D-M9P-746/D-M9B-746 MHR Mounting screwM2.5 x 4l Slotted set screw Indicator light DC(-) Blue MHK D-M9P-746 MHS 2.6 746 DC(+) Brown MHC
Flat head watchmakers screwdriver L 5 to 6 When auto switch D-M9 is used Auto switch mounting screw M2.5 x 4l Auto switch L Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6 mm to tighten the auto switch mounting screw. The tightening torque should be about 0.05 to 0.15 Nm.
MHF2-16D MHZ MHF2-16D1 Flat head watchmakers screwdriver MHF MHF2-16D2 MHL MHF2-20D 5 to 6 Auto switch mounting screw M2.5 x 4l MHR MHF2-20D1 MHK MHF2-20D2 Auto switch MHS MHC MHT MHY Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6 mm to tighten the auto switch mounting screw. The tightening torque should be about 0.05 to 0.15 Nm.
Supply Unit: W (Flow Adjustment Valve + Stop Valve), Rated Flow Range: 04 (0.5~4L/min), Thread: N (NPT), Port Size: 03 (3/8)
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5~4L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: Rc, Port Size: 03 (3/8), Flow Switch Output: AT (Integrated Display; Out 1: NPN; Out 2: (NPN) ⇔ NPN ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous
ISA11-4L-01BG ZSE2 ISE2 ISA15-1-01G ZSP ISl ZSM Accessories (Optional) PFl Bracket ISA-1-A Gauge G33-3-01 DIN rail ISA-2-1 to 7 IFl Gauge/G33-3-01 Bracket /ISA-1-A DIN rail/ISA-2-1 to 7 Material: SPC (Nickel plated) Material: Aluminum 10 hex. 100 110 q w e r t L 90 10 25 5 4-4.5 7.5 30 R1/8 34 42 28 4.5 35 27 9 16.5 13 5.6 L Applicable model Part No. 105 140 175 210 245 280 315 Description
ISA11-4L-01BG ZSE2 ISE2 ISA15-1-01G ZSP ISl ZSM Accessories (Optional) PFl Bracket ISA-1-A Gauge G33-3-01 DIN rail ISA-2-1 to 7 IFl Gauge/G33-3-01 Bracket /ISA-1-A DIN rail/ISA-2-1 to 7 Material: SPC (Nickel plated) Material: Aluminum 10 hex. 100 110 q w e r t L 90 10 25 5 4-4.5 7.5 30 R1/8 34 42 28 4.5 35 27 9 16.5 13 5.6 L Applicable model Part No. 105 140 175 210 245 280 315 Description
0.3 VDW20 VDW20 3.2 CV = 0.3 VDW20 2.3 CV = 0.18 VDW30 VDW30 3 CV = 0.28 VDW30 3 CV = 0.28 VDW20 VDW20 2.3 CV = 0.18 VDW30 2 CV = 0.16 VDW30 VDW30 2 CV = 0.16 10 Flow rate Ql /min VDW 1.6 CV = 0.07 10 20 VDW VDW 1.6 CV = 0.07 10 20 5.0 VDW10 VDW10 1 CV = 0.03 VDW10 1 CV = 0.03 1.0 0.1 0.001 0.01 0.1 1 10 Pressure differential P = (P P) MPa Viewing the graph To generate a water flow of 4l
Switch mounting screw (M2.5 x 4l) (included with auto switch) Tightening torque Tighten with a torque of 0.05 to 0.1Nm. As a rule, it should be turned about 90 past the point at which tightening can be felt.
CEP1 CE1 Auto switch CE2 ML2B Flat head watchmakers screwdriver C J G5-S CV MVGQ Switch installation screw (M2.5 x 4l) (Accessory option) CC RB J Note) When adjusting the auto switch mounting screws, use a flat head watchmakers screwdriver. The guideline of the tightening torque is 0.05 to 0.1 Nm. Turn another 90 from the position where tightening is felt by hand.
M2.5 x 4l (Included with auto switch) Fig. (2) Auto switch mounting Lead wire cover Fig. (3) Installation of lead wire cover Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. For detailed specifications, refer to page 8-30-1. Normally closed (NC = b contact), solid state switch (D-F9G/F9H/Y7G/Y7H type) are also available.
MY2C MY2 H/HT MY3A MY3B M2.5 x 4L (Included with auto switch) MY3M Fig. (2) Auto switch mounting Lead wire cover Fig. (3) Installation of lead wire cover D-X Technical Data 1361 MY1W Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 3 to 12 for Actuator and Auto Switch Precautions.