How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 646 B AS Series Speed Controller: Standard Type Elbow Type (Metal Body) Note) The flow rate characteristics are representative values.
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 23 04 06 01 03 07 3.2 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2. With One-touch fitting 3 Series VR1211F Application Circuit Example Output 3 When "A" and "B" having different pressure conditions are turned ON, output 1 and output 2 go ON.
(Socket side with cover) Panel mounting hole Panel mounting hole (2) Align at mark B of the plug and socket cases and turn them against each other to connect the two cases. 4-4.3 M4 round head screw 40.5 59.5 Screw in the clamp ring to complete the connection. (3) SMC 6 1 19 26 36 2 5 4 3 B 11 36 45 38 DMK12 B 43 43 Installation of cover The cover can be installed on both the plug case or
The M12 SPEEDCON connector connection method is explained below. (1)Align mark B on the metal bracket of the cable connector (plug) with mark A. (2)Align with mark C on the unit and insert the connector vertically. If they are not aligned, the connector cannot be connected correctly. (3)When mark B has been turned 180 degrees (1/2 turn), wiring is complete.
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,
industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
Accessory (Option) Basic size (Applicable compressor kW) F With screw flange D With auto-drain Port size Symbol 2 Screw type Reciprocating type 2.2 7.5 15 22 37 55 75 04 06 14 20 30 Rc 1 2 Rc 3 4 Rc 1 1 2 Rc 2 3B flange HAW2 HAW7 HAW22/37 HAW55/75 HAW110 Caution on Design 7 22 22 Warning 1.
) With 4 selftapping screws Note) ISO228 compliant Port size Port size Rated flow range 501 102 No 04 * 1/2 * bracket Output specifications OUT1 OUT2 A B C D NPN PNP NPN NPN PNP PNP NPN PNP NPN PNP Analog 1 to 5 V Analog 4 to 20 mA Note) Each option is not assembled with E Analog 1 to 5 V the product, but shipped together.
thread M 1 8 KAH06-U01 14.5 6 5 12 19.5 17 1 4 KAH06-U02 13 17 14 12 13.1 13.1 10
Cover B Element Cover A 1 ZFC100-06 ZFC200-06 Replacement Parts ZFC200-08 0.1 1 10 100 Description Part no.
L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model Flange port size Note) Rated flow rate (L/min) Model/Rated Flow Rate FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA-24 FHIA-28 FHIA-32 1/2B 30 3/4B 50 1B 95 1 1/4B 150 1 1/2B 220 2B 350 2 1/2B 550 3B 770 3 1/2B 1000 4B 1300 The symbol represented by indicates the type of applicable hydraulic fluid.
(A)4 2(B) (A)4 2(B) 4(A) 2(B) (EA)5 1 3(EB) (EA)5 1 3(EB) (P) (P) 3-position pressure center 5(EA) 3(EB) 1(P) (A)4 2(B) N.O. valve x 2 pcs. 2(B) 4(A) (EA)5 1 3(EB) (P) 3(EB) 5(EA) 1(P) N.C. valve, N.O. valve x 1 pc. of each 2(B) 4(A) 3(EB) 5(EA) 1(P) Component Parts No.
Rc G NPT Nil F N Port size 04 1/2 (Female thread) 14-20-51 Series ADH4000 Construction Component Parts q o i u !1 No.
P), 3(R) port] Applicable tubing O.D.: 8, 5/16" 13.3 (Pitch) P = 10.5 24 13.3 24 36.7 16.2 34 16.2 17 34 B 2 B 2 B 2 B 2 B 2 R 3 B 2 B 2 B 2 B 2 PE R 3 B 2 R 3 R 3 P 1 A 4 A 4 A 4 A 4 A 4 P 1 A 4 A 4 A 4 A 4 X P 1 P 1 A 4 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4, 5/32" 6, 1/4" One-touch fitting (X, PE port) Applicable tubing O.D.: 6, 1/4" M5 x 0.8 [4(A), 2(B) port] Applicable
DI2 DI1 DI0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 7 (b) Incremental value command system 1) Point table Set the point table values by using set up software(MR Configurator2TM) or the operation section. Set the position data (target position), servo motor speed, acceleration time constant, deceleration time constant, dwell and auxiliary function in the point table.
3-22 23 Cassette Type Manifold Plug-in Type Series SZ3000 Dimensions: SZ3000 Plug-in 1 2 SS5Z3-60PD Stations B(26 pins) 2n1-M5 x 0.8 [4(A), 2(B) port] With external pilot 4One-touch fitting [1(P), 3(R) port] Applicable tubing O.D.: 8 13.3 (Pitch) P = 10.5 13.3 24 24 16.2 16.2 17 36.7 SV 34 34 B 2 B 2 B 2 PE B 2 B 2 B 2 B 2 B 2 B 2 B 2 R 3 R 3 R 3 R 3 SZ P 1 P 1 P 1 P 1 A 4 A 4 A 4 X A 4 A
3-22 Cassette Type Manifold Plug-in Type Series SZ3000 Dimensions: SZ3000 Plug-in 1 2 SS5Z3-60PD Stations B(26 pins) 2n1-M5 x 0.8 [4(A), 2(B) port] With external pilot 4One-touch fitting [1(P), 3(R) port] Applicable tubing O.D.: 8 13.3 (Pitch) P = 10.5 13.3 24 24 16.2 16.2 17 36.7 SV 34 34 B 2 B 2 B 2 PE B 2 B 2 B 2 B 2 B 2 B 2 B 2 R 3 R 3 R 3 R 3 SZ P 1 P 1 P 1 P 1 A 4 A 4 A 4 X A 4 A 4
KK KK EA MM MM B B E/2 4-NT ND Deep SN + Stroke (A + B) Stroke B Stroke A G C A TN C G A E XT XT LD + Stroke (A + B) WF WF ZZ + Stroke (A + B) (in) ZZ PC KK Y R XT G A LD Bore (in) DD C NT ND AA EA D B MM WF P K E SN TN EE 9.44 1.30 7/16-20 1.71 1.43 1 15/16 1.26 3/4 7.44 150 (1.5") 1/4-28 3/8 1/4-20 9/32 2.02 0.3 9/16 1 1/8 5/8 1 2.36 9/32 2 5.56 5/8 3/8 9.52 1.30 7/16-20 1.71 1.84 1 15