Pressure setting for pressure control function 0.10 to 0.50 MPa (5) PressLimit Function disabled 0.50 MPa Function enabled By default 5.4 Description of the Screen HRL Series 5-42 HRX-OM-Y098 Chapter 5 Display and Setting of Various Functions Discharge pressure alarm (AL21/AL23/AL24/AL26) 5.

Valve diagnostics 1 . 5-4 Valve diagnostics 1 Bit 0 Valve 0, 1 diagnostics 01() 1 Valve 2, 3 diagnostics 01() 2 Valve 4, 5 diagnostics 01() 3 Valve 6, 7 diagnostics 01() 4 Valve 8, 9 diagnostics 01() 5 Valve 10, 11 diagnostics 01() 6 Valve 12, 13 diagnostics 01() 7 Valve 14, 15 diagnostics 01() 5.1.1.4.

How to Order AS500 AS420 JIS Symbol AS 42 0 02 Option Body size Nil None Caution 42 50 60 80 90 1/2 standard 3/4 standard 1 standard 1 1/4 standard 1 1/2 standard H (1) High temperature (5 to 80C) Low temperature (30 to 60C) Bore size L (2) Be sure to read before handling.

1 Valve 2, 3 diagnostics 01 2 Valve 4, 5 diagnostics 01 3 Valve 6, 7 diagnostics 01 4 Valve 8, 9 diagnostics 01 5 Valve 10, 11 diagnostics 01 6 Valve 12, 13 diagnostics 01 7 Valve 14, 15 diagnostics 01 Valve diagnostics 2 . 5-5 Valve diagnostics 2 Bit 0 Valve 16, 17 diagnostics 01 1 Valve 18, 19 diagnostics 01 2 Valve 20, 21 diagnostics 01 3 Valve 22, 23 diagnostics 01 4 Valve 24, 25

Thread NPT Hex Part Number Weight (grams) Bag/Box Quantity D1 D2 D3 D4 L1 L3 3/8 3/8-18 22.23 KV2KF11-36 17.9 21 5.4 42 100/200 18.1 17.9 18.2 26.2 28.2 52.4 8 Series KV2 Male Run Tee KV2Y_ _-_ _S D2 Applicable Tube A D1 L1 Applicable Tube B MA MB L3 D5 D6 A L2 Hex Thread D3 D4 A* MA Min. Flow Dia. App. A Tube OD (inch) App. B Tube OD (inch) Thread NPT Hex Part Number D1 Wt.

Stations 02 2 stations IN port direction ... ...

51 53.5 S 51 54 57 57 Q 27 30 32 32 R 40 48 56 58.5 41 50 60 68 64 76 86 91 18 24 30 35 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5 M5 VCA21 VCA31 1/4 1/4, 3/8 3/8, 1/2 3/4 VCA41 4 Series VCA How to Order Manifolds (VCA20) VV2C A 2 02 02 How to Order Manifold Assemblies (Example) Enter the valve and option models to be mounted under the manifold base part

Rod end male thread (mm) Bore (mm) A1 C1 H1 L1 X 125 140 160 45 45 50 58 58 64 42 42 47 M30 X 1.5 M30 X 1.5 M36 X 1.5 199 199 219 CU CQS CQ2 MU Above auto switch: D-A73/A80 Refer to below for auto switch setting position and mounting height.

Auto Switch Mounting Heights (mm) D-F7 D-F7W D-J79 D-J79W D-F7BA D-F7NT D-F79F D-A7H D-A80H D-M9 D-M9W D-M9A D-A9 D-M9V D-M9WV D-M9AV D-A9V D-A7 D-A80 D-F7V D-F7WV D-F7BAV D-J79C D-A79W D-A73C D-A80C Bore size (mm) U 26.5 24.5 28 34 37.5 47.5 57.5 U 26.5 29 32.5 38.5 42 52 62 U 26.5 27 30.5 36.5 40 50 60 U 24.5 31.5 35 41 47.5 57.5 67.5 U 25.5 32.5 36 42 48.5 58.5 68.5 U 31.5 38.5 42 48 54.5

38.5 41.5 37.5 30.5 32.5 50 36 50 41 42 48 44.5 47.5 43.5 36.5 38.5 63 39.5 56.5 47.5 48.5 54.5 51 54 50 40 42 80 49.5 66.5 57.5 58.5 64.5 61 64 60 50 52 100 59.5 76.5 67.5 68.5 74.5 71 74 70 60 62 7-6-24 25 Compact Cylinder: Standard Type Double Acting, Double Rod Series CQ2W 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 How to Order CUJ Without auto switch CU CQ2W B 20 30 D CQS B 20 30 D J79W

Throttle valves and dual speed controllers for recommended speed adjustment of CYP cylinders Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Operation Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01

-01-06-X214 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Universal type (throttle valve) 10-AS2301F-01-06-X214 1.

-01-06-X214 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Universal type (throttle valve) 10-AS2301F-01-06-X214 1.

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.

22 For Positive Pressure ZSE40 01 22 For Vacuum/Compound Pressure Option Set pressure range Nil F For vacuum pressure For compound pressure Nil None Bracket A (ZS-24-A) 10.0 to 101.3kPa 100.0 to 100.0kPa A Piping specifications Bracket B (ZS-24-B) W1: Rc1/8 01: R1/8 (with M5 female threads) T1: NPT1/8 (with M5 female threads) Rc1/8 Reverse pressure two directions B R1/8, NPT1/8 M5 x 0.8

22 For Positive Pressure ZSE40 01 22 For Vacuum/Compound Pressure Option Set pressure range For vacuum pressure For compound pressure None Bracket A (ZS-24-A) Nil 10.0 to 101.3kPa 100.0 to 100.0kPa Nil F A Piping specifications Bracket B (ZS-24-B) W1: Rc1/8 01: R1/8 (with M5 female threads) T1: NPT1/8 (with M5 female threads) Reverse pressure two directions B R1/8, NPT1/8 Rc1/8 M5 x 0.8

(Refer to Precautions on page 16-2-24 for details.) 1.5 01: R 1/8 T1: NPT 1/8 Data ZSE40(F)/ISE40-W1 2-M4 x 0.7 thread depth 4 20 30 Rc 1/8 MPa 7 19 20 30 OUT2 OUT1 SET 6.5 R 6.4 18.35 Atmospheric release port Lead wire length 600 (3000) 3.5 12.4 7.8 7 2.5 2.6 30 15.2 42 10.7 4 6 For splash proof use (IP65), insert an air tube into the atmospheric release port.