In a locked state, do not apply impacts, strong vibrations or rotational forces. Do not apply a impacts, strong vibrations or rotational forces from external sources, because this could damage or shorten the life of the lock unit. 4. The locking of the fine lock cylinder is directional.
In a locked state, do not apply impacts, strong vibrations or rotational forces. Do not apply a impacts, strong vibrations or rotational forces from external sources, because this could damage or shorten the life of the lock unit. 4. The locking of the fine lock cylinder is directional.
Do not operate in locations with an atmosphere of corrosive gases, chemicals, sea water, water or steam, or where the same substances will adhere to the regulator. 2. Do not operate in locations where vibration or impact occurs. 3. In locations under direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off the radiated heat. 5.
Do not use in locations where static electric charges will be a problem. Please consult with SMC regarding use in this kind of environment. 2. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. 3. Do not use in environments where there is direct contact with liquids such as cutting oil, lubricating oil or coolant oil, etc.
Do not press this button, as it can result in damage to the product.
PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.
Do not use in a location having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. Do not use in locations where radiated heat will be received from nearby heat sources. Maintenance Warning 1. Maintenance should be performed in accordance with the procedures in the Operation Manual.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bracket mounting Mount the bracket using the mounting screws supplied. The required tightening torque is 0.420.04 Nm.
Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. Refer to the construction drawings for silencer materials. 2. Avoid exposure to direct sunlight. 3. Do not operate in locations where vibration or impact occurs. 4.
Please execute "initialize (refer to P30)" when ITV do not operate normally after restarting the power supply. Please contact us, when ITV do not operate normally after initialize. Reading or writing errors occurred in EEPROM. System error Please contact us when ITV do not operate normally after restarting the power supply. Reading and writing errors occurred in memory.
. * Products with tiny scratches, marks, or display color or brightness variations which do not affect the performance of the product are verified as conforming products.
Do not use the cylinder as a shock absorber. Weight (kg) & Warning ::..;: . ' Bor~ I SZ" (m",) 140 160 "',' 1 .25 Using the cylinder as a shoe\< absorber may cause damage. 6.50 9.07 ! Basic 5.46 i 2. Do not open the cushion valve beyond F, oot . , . 7.49 . , the stopper.
Applicable bore size C D d H Applicable bore size C D d H 5 12.5 15 26 30 M8 x 1.25 8 M22 x 1.5 26 13 20 20 SOR-20 NT-02 6 16.5 19.6 32 36.9 M10 x 1.25 8 M24 x 1.5 32 17 25/32 25 SOR-25 NT-03 8 21.0 25.4 38 43.9 M14 x 1.5 9 M30 x 1.5 38 22 40 32 SOR-32 NT-04 11 26 31 41 47.3 M18 x 1.5 11 M33 x 2.0 41 27 50 40 SOR-40 NT-05 11 26 31 M18 x 1.5 27 63 NT-05 13 31 37 M22 x 1.5 32 80 NT-08 16 39
Hole diameter 5 9 Features 1 3 Port Direct Operated Poppet 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry Rated voltage 100VAC 50/60 Hz 200VAC 50/60 Hz 110VAC 50/60 Hz 220VAC 50/60 Hz 24VDC 12VDC 240VAC 50/60 Hz Other DO-DIN terminal (without connector) 1 2 3 G-grommet (lead wire length: 300mm) H-grommet (lead wire length: 600mm) D-DIN type
Do not apply a lateral load to the external slider. When a load is mounted directly to the cylinder, variations in the alignment of each shaft center cannot be assimilated, which results in the generation of a lateral load that can cause malfunction.
Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this equipment. 2. If electric power is shut off while pressure is being applied, pressure will be retained on the output side.
Do not apply any impact when you load the cylinder in the locked position.
Note 2) When using the D-M9lA, D-M9lAV or Y7BA, do not use the steel set screws which are included with the above auto switch mounting brackets (BA7-lll, BA4-lll).
Do not use for intermediate cylinder stops. This cylinder is designed for locking against inadvertent movement from a stationary condition. Do not perform intermediate stops while the cylinder is operating, as this will shorten its service life. 2. Select the correct locking direction, as this cylinder does not generate holding force opposite to the locking direction.