SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-04-DO-00N"

Blanking plug KQ2P23 04 06 Dimensions It is inserted into an unused cylinder port and SUP/EXH ports. Purchasing order is available in units of 10 pieces.

AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 Material Part no.

If the tubing is inserted without holding the elbow, excessive force can be applied to the valve and fitting assembly, causing air leakage or damage, etc. 1) Nylon tubing within 0.1 mm 2) Soft nylon tubing within 0.1 mm 3) Polyurethane tubing within +0.15 mm, within 0.2 mm Do not use tubes which do not meet these outside diameter tolerances.

If the tubing is inserted without holding the elbow, excessive force can be applied to the valve and fitting assembly, causing air leakage or damage, etc. 1) Nylon tubing within 0.1 mm 2) Soft nylon tubing within 0.1 mm 3) Polyurethane tubing within +0.15 mm, within 0.2 mm Do not use tubes which do not meet these outside diameter tolerances.

Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not operate in locations where vibration or impact occurs. 3. In locations which receive direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off any radiated heat. 5.

When a pressure gauge is mounted to the regulator, please do not exceed the maximum display pressure. It may lead to a malfunction.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Do not use the lubricator where containing those. Effects organic solvents and chemicals, and where these elements are likely to adhere to the equipment.

Regulator and filter regulator 1) Be sure to unlock the handle before adjusting the pressure and to lock it after the pressure is set. 2) During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 3) Do not install it iin an area that is exposed to high temperature or humidity, because doing so will lead to improper operation

Do not use in an atmosphere where corrosive gases, chemicals, sea water, water, or water steam is present. Do not use in cases where there is direct contact with any of the above. 2. Do not use in a place subject to heavy vibration and/or impact. 3. Do not use in an environment where flammable gas or explosive gas is present. Usage may cause a fire or explosion.

Unused bit is fixed to 0. 1: These alarms do not occur on the product of the cooling method -W. 2: These alarms do not occur on the product of the power specification '-20'. 3: These alarms do not occur on the product of the cooling method -A. 4.10 Register Map HRSH Series 4-20 HRX-OM-Q033 Chapter 4 MODBUS communication function 4.10.7 Circulating fluid set temperature The circulating fluid

Unused bit is fixed to 0. 1: These alarms do not occur on the product of the cooling method -W. 2: These alarms do not occur on the product of the cooling method -A. 3: These alarms do not occur on HRS200 series. 4.10 Register Map HRS100/150 Series 4-20 HRX-OM-S010 Chapter 4 MODBUS communication function 4.10.7 Circulating fluid set temperature The circulating fluid set temperature can be

Do not use tools, such as pliers, to rotate the knob. This can cause the idle rotation of the knob or damage. 3. Do not overtighten the lock nut. It is possible to tighten the lock nut (hexagon) manually. When tightening further with tools, tighten by approximately 15 to 30. Overtightening may cause breakage.

Tubing extensions size Nut Insert bushing Model Size Insert pin/Name plate symbol LQ1E21-T-R8 2 2-06 LQ1-2N06 LQ1-2B06 8 x 6 LQ1E21-T-R9 2 2-06 LQ1-2N06 LQ1-2B06 10 x 8 LQ1E21-T-R10 2 2-06 LQ1-2N06 LQ1-2B06 12 x 10 LQ1E22-T-R8 2 2-04 LQ1-2N04 LQ1-2B04 6 x 4 LQ1E22-T-R9 2 2-04 LQ1-2N04 LQ1-2B04 8 x 6 LQ1E22-T-R10 2 2-04 LQ1-2N04 LQ1-2B04 10 x 8 LQ1E22-T-R11 2 2-04 LQ1-2N04 LQ1-2B04 12 x 10

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.