Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.
Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water, or where there is direct contact with same. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.
Do not exceed specified current or the LED might be damaged and not function. 3. The indicator light is lit when switch is off for D-P70 4. Do not drop, dent, or allow excessive impact to cylinder during handling. 5. Keep at least 20mm away from each other when 2 or more cylinders with high magnetic field resistance auto switch are mounted in parallel. and D-P75.
Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not operate in locations where vibration or impact occurs. 3. In locations which receive direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off any radiated heat. 5.
Do not operate or set with wet hands. This may lead to an electric shock. End plate bracket (EX600-ZMA2) SUPPLIERS DECLARATION OF CONFORMITY Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Connector (Base only) (2) Add more units.
Do not use the product for flammable fluid. Fire or explosion can result. Only air, N2, are applicable. Flow direction: Left Right Flow direction: Right Left Default setting Rotation of the display Function (Main display) Do not use the product in a place where static electricity is a problem.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction or damage to the product can result. Verify the specifications before use. S S S Flow direction (1) Press the SET button once when the item to be changed is displayed on the display. The set value on the sub display (right) will start flashing.
The received message is deleted if the calculation result and received CRC do not match.
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV2Q* MANIFOLD VQ 2-PORT, 2J, VV2Q* NO SIZE RATING, 1.19049 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV2Q* MANIFOLD VQ 2-PORT, 2J, VV2Q* NO SIZE RATING, 1.90148 lb
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity. The VQ20/30's long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Manifold for VQ20/30 pilot operated valve
Please prepare according to 3.2 Connected explanation.In order to avoid malfunction, do not connect to any place other than those shown in 3.2 Connected explanation.
Housing assembly Body Caution M5 hexagon socket head cap screw q M6 special screw (Do not disassemble.) Caution M6 special screw (Do not disassemble.) M5 hexagon socket head cap screw w Fig.1 Caution 1. Before disassembling, be sure to shut off the pressure supply, and then release the residual pressure. 2. After assembly, confirm that there is no fluid leakage.
As compared with the types which do not integrate the back pressure check valve, C value of the flow rate characteristics goes down. For details, please contact SMC. 2. Do not switch valves when A or B port is open to the atmosphere, or while the actuators and air operated equipment are in operation.
The received message is deleted if the calculation result and received LRC do not match. Consecutive 8 bits of the message are added, and the result without carry (overflow) is converted to 2's complement.
In a locked state, do not apply impacts, strong vibrations or rotational forces. Do not apply a impacts, strong vibrations or rotational forces from external sources, because this could damage or shorten the life of the lock unit. 4. The locking of the fine lock cylinder is directional.
1 Q=226S P(P2+0.1013) Sonic flow : P1+0.1013 1.89(P2+0.1013) Do not use in an explosive environment. 2 Q=113S(P1+0.1013) Q : Flow rate [ /min(ANR)] S : Effective area (mm2) P : Differential pressure (P1-P2) [MPa] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] Do not use in locations subject to heavy vibration and/or shock.
KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-01 KQ2P-03 KQ2P-07 KQ2P-09 3.2 4 6 8 16 16 18 20.5 31.5 32 35 39 1/8" 5/32" 1/4" 5/16" 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 5 6 8.5 10 Port plug VVQ0-58A The plug is used to block the cylinder port.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 https://www.smcworld.com 2023 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.