No Thread IMPERIAL Code : Thread Form 00 : None (No reduction in METRIC Code : Thread Form METRIC Code : Thread Form Code : Thread Form 27 : 3/4-10 60 : M3 x 0.35 88 : M14 x 1.5 piston rod diameter) 28 : 3/4-16 61 : M3 x 0.5 89 : M20 x 1.5 01 : 2-56 29 : 7/8-9 62 : M4 x 0.5 90 : M12 x 1.25 02 : 2-64 30 : 7/8-14 63 : M4 x 0.7 91 : M42 x 1.5 03 : 4-40 31 : 1-8 64 : M5 x 0.5 92 : M24 x 3.0 04
No Thread IMPERIAL Code : Thread Form 00 : None (No reduction in METRIC Code : Thread Form METRIC Code : Thread Form Code : Thread Form 27 : 3/4-10 60 : M3 x 0.35 88 : M14 x 1.5 piston rod diameter) 28 : 3/4-16 61 : M3 x 0.5 89 : M20 x 1.5 01 : 2-56 29 : 7/8-9 62 : M4 x 0.5 90 : M12 x 1.25 02 : 2-64 30 : 7/8-14 63 : M4 x 0.7 91 : M42 x 1.5 03 : 4-40 31 : 1-8 64 : M5 x 0.5 92 : M24 x 3.0 04
, B , C ) 27 2.5 2 3-R1.5 2-4.5 through 12.5 37 8 6.5 10.3 6.5 31 4.2 2 31.5 2 36h9 0 0.062 27 16 9 5 4.5 Angle adjustment bolt 2-4.5 through 3-R1.5 2-M3 x 0.5 1 5 Adjustment: Max. 7.5 0.5 B port A port +0.025 0 3-3H9 long groove depth 2.5 4g6 0.004 0.012 ( A , B , C ) 9h9 0 0.036 29 4-M4 x 0.7 depth 8 2-M3 x 0.5 depth 4 0 0.062 36h9 Top ported: MSUA1-SE A port B port 9.5 2-M3 x 0.5 8.5 11
Features 2 Manifold Variations Wiring Connection Common specifications Flat ribbon cable (26 pins) Flat ribbon cable (20 pins) connector box Plug-in type D-sub connector (25 pins) Plug-in type flat ribbon cable (26, 20, 10 pins) Plug-in type terminal block (9, 18 pins) Serial transmission unit Negative common Valve Series Individual wiring Positive common Manifold Variations PC Wiring 5
(A) (z) Z m x g Examine M3. M3 = m x g x Y = 5.5 x 9.8 x 30/1000 = 1.6 [Nm] 2B = M3/M3max = 1.6/17.0 = 0.10 Refer to [3] Calculation for Overall Center of Gravity in the Y-axis on front matter 7. M3 Find the value of M3max when Va = 200 mm/s from Graph (11) x.
MSUA1 MSUA1-S,SE C 8 x M3 x 0.5 depth 5 51 31 38 23.5 B 25 4 x M4 x 0.7 depth 4 22.5 4.5 +0.025 0 2.5H9 A Long groove depth 4 (Positioning pin hole) 35h9 0 0.062 22.5 3 x 3H9 depth 3 +0.025 0 +0.043 0 17 H9 ( A , B , C ) 27 2.5 2 2 x 4.5 through 12.5 37 8 6.5 10.3 6.5 31 4.2 2 31.5 2 36h9 0 0.062 27 16 9 5 4.5 Angle adjustment bolt 2 x 4.5 through 2 x M3 x 0.5 1 5 Adjustment: Max. 7.5 B port
Cable connector (4-wire) Right angle type Cable connector (4-wire) Straight type 52 Mounting hole 4 x 7 40 (31) F.R.L.
x 0.5 (port size) 2-M3 x 0.5 (port size for axial piping type MTS8-P) 9 2-M3 x 0.5 Effective length 5 0.2 5 +0.035 +0.025 4 16 0.2 22 12 M2.5 x 0.45 12 41 + Stroke 53 + Stroke 9 15 0.2 9 4-M3 x 0.5, effective length 5 10 15 0.2 Rod end male threads Width across flats 3.5 +0.035 +0.025 4 M3 x 0.5 3.9 M3 x 0.5 6.4 7 8 4 24 5.5 2.4 Stud bolt part number: MT-S8 Rod end nut part number: NTJ-006A
depth 3 10.05 +0.030 0 D B 16.5 3.5 18 14 13 20 6 +0.030 0 depth 2.5 2.5 6 E 5 2 x M4 x 0.7 Piping port F QL 6 13.5 Prepared hole diameter 3.3 2 x M3 x 0.5 (Plug: M-3P) 170.05 6 (fitting seat surface dimension) M3 x 0.5 Vacuum suction port Stroke: S M 1 Mounting base side B D Piping port A 2 x M3 x 0.5 A 5 5.5 3.2 J 2.4 Z Section AA 3.5 depth 2 2.5 +0.030 0 7 +0.030 0 depth 2 2.5 Q QL 11
0.5 depth 3 +0.030 0 D B 16.5 3.5 18 14 13 20 6 +0.030 0 Depth 2.5 2.5 6 E 5 2-M4 x 0.7 Piping port F QL 6 13.5 Prepared hole diameter 3.3 2-M3 x 0.5 (Plug: M-3P) 6 (fitting seat surface dimension) 170.05 M3 x 0.5 Vacuum suction port Stroke: S M 1 Mounting base side B D Piping port 2-M3 x 0.5 A 5 5.5 A 3.2 J 2.4 Z Section AA 3.5 Depth 2 2.5 +0.030 0 7 +0.030 0 Depth 2 2.5 Q QL 11-/22-MXPJ6
After checking the detection position, tighten M3 screws to fix the auto switch so that the bottom of the auto switch contact the cylinder tube. (The tightening torque of the M3 screw must be 0.5 to 0.7Nm.) Tighten the auto switch mounting screw(M4) to fix the auto switch mounting bracket.
JXC-OMU0026 Part A Part B Holding screw M5X14 (2) Grounding Fit the grounding cable with crimped terminal between the M3 screw and shakeproof washer as shown below and tighten the screw. M3 screw Shakeproof washer Grounding cable (with crimped terminal) Caution The cable with crimped terminal and shakeproof washer must be prepared by the user.
Tightening of M3, M5, and M6 screws 1) M3 After tightening by hand, tighten an additional 1/4 rotation with a tool. 2) M5 and M6 After tightening by hand, tighten an additional 1/6 rotation with a tool. Over tightening can cause damage to the threads and/or air leakage due to deformation of the gasket. Under tightening can cause loose threads and air leakage, etc. 1.
B C E G H K MM NN 5 st 10 st F 15 st R 5 st 10 st S 15 st W Q 5 st 10 st Z Bore size (mm) 6 10 15 A 15 st M3 x 0.5 3.5 3 8.5 9 41.5 26.5 34.5 19.5 27.5 12.5 3 6 32.5 13.9 25.5 12 18.5 7 M10 x 1.0 9 M4 x 0.7 3.5 5 12 46 28 39 21 32.5 14.5 4 6 34 22 27 19 20.5 10 M15 x 1.5 13 12 M5 x 0.8 4.2 6 14 50 29 43.5 22.5 37.5 16.5 5 7 36 31 29.5 27 23.5 12 M22 x 1.5 20 19 6-2-16
B C E G H K MM NN 5 st 10 st F 15 st R 5 st 10 st S 15 st W Q 5 st 10 st Z Bore size (mm) 6 10 15 A 15 st M3 x 0.5 3.5 3 8.5 9 41.5 26.5 34.5 19.5 27.5 12.5 3 6 32.5 13.9 25.5 12 18.5 7 M10 x 1.0 9 M4 x 0.7 3.5 5 12 46 28 39 21 32.5 14.5 4 6 34 22 27 19 20.5 10 M15 x 1.5 13 12 M5 x 0.8 4.2 6 14 50 29 43.5 22.5 37.5 16.5 5 7 36 31 29.5 27 23.5 12 M22 x 1.5 20 19 6-2-16
Prefix it to the part nos. of the solenoid valve, etc. 39 Series SYJ700 Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blanking Plate Assembly Body ported (Type SYJ72) Base mounted (Type SYJ74) Model no.: SYJ700-10-2A (In common for body ported type and base mounted type) Round head combination screw M3 x 8, Matt nickel plated Round head combination screw M3 x 31, Matt
Av = Q (8) P Av : Flow coefficient [m2] Q : Flow rate [m3/s] P : Pressure difference [Pa] : Density of fluid [kg/m3] (3) Formula of flow rate It is described by the known unit. Also, the flow characteristics line shown in the Graph (2).
Hook Covering ZSE1-18, -19 Pressure setting trimmer 1 Pressure setting trimmer 2 3.