34 M42 x 1.5 34 1/4, 3/8, 1/2 Optional specifications Digital pressure switch Round type pressure gauge Note 3) Bracket mount dimension Panel mount Model Z ARP20(K) H J H J M N Q R S T U V W Y 27.8 1021 1021 1021 44 40 69 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 ARP30(K) 27.8 44 41 70 41 40 44 6.5 8 53 2.3 31 38.5 19 7 ARP40(K) 27.8 44 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The

Remote (2) Mount the end plate bracket (EX600-ZMA2) to the end plate using 2-M4 x 14 screws. Tightening torque: 0.7 to 0.8 Nm 1 2 3 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Remote connection system status Specification Str Frunzei 29, Sector 2, Bucharest, Romania W-MS SLOVAKIA (421) 41 321321 1 Remote (EX600-WSV#) can be used regardless of the communication specification of the base. (3) Set the "base" system.

(Full span) Scale 230' Mounting screw M3X O .5 X 14 (Black zinc chromate) Case Polyacetal Cover Polycarbonate Material O-ring NBR Dimensions (mm) 20 27.5 16 2.5 M3 X D.5 Setting The Indicator Needles eSetting indicators: eCover removal: Move the needle with fingers. Adjust 2 green needles at upper and tower pressure limits.

SI Unit for VQC/S0700 Series Valves ( EX500-Q 01 ) SI Unit for SV Series Valves ( EX500-S 01 ) M3 28: 4 pcs. ( Plus-minus slot round head screw ) Supply/exhaust block assembly Supply/exhaust block assembly 1.

State (7): AL.14 report since 45 sec has elapsed since the circulating fluid temperature deviated, because it is outside the upper temperature monitoring range. TEMP OUT output ON. State (8): The alarm is reset manually, the temperature monitoring upper and lower limit range is out, so "AL.14", "AL.15" warning continue.

output is set) Elapsed time Alarm manual reset Alarm manual reset State : An alarm "AL.14" is issued when the chiller is activated.

(P.64) * 7 PLC DeviceNet LED LED PWR ALM MS NS DeviceNet (()) LED 8.LED (P.31) (JXC)LEDNSPLC PLC 20.P.80 PLC 10 - 8() ()() () 9 10.P.33 PLC 14.P.53 11 - 3 3.1.

The cooling capacity required for the oscillator is, 20 [kW] 6 [kW] = 14 [kW] Considering a safety factor of 20%, 14 [kW] x 1.2 = 16.8 [kW] r Calculate based on the laser output. Laser output power 6 [kW], conversion efficiency 30% The oscillators power consumption is, 6 [kW] 0.3 = 20 [kW] Example 2: When the heat generation amount in the users equipment is not known.

VS7 S kit (Serial transmission) Kit F kit (D-sub connector) T kit (Terminal block) P kit (Flat cable connector) U S F 15 pin U S P 26 pin U S A S U S P 20 pin U S P 16 pin U S P A B C 10 pin F 25 pin T2 T1 Model Max. number 16(1) 14 8 8 16 16 16(1) 14 16(1) Note 1) Due to the limitation of internal wiring.

6 10 Bearing stopper Size 6: Aluminum alloy Size 10: Carbon steel 11 Motor plate Aluminum alloy Anodized 12 Guide ring Aluminum alloy Size 10 only 13 Bearing 14 Bushing Oil impregnated sintered copper alloy 15 Soft wiper r w !5 !4 !3 e u !

Mounting with panel mount adapter Secure the panel mount adapter with two M3 x 8L mounting screws. Panel Front protective cover (Part no. ZS-27-01) M3 x 8L Panel mount adapter (Part no. ZS-27-C) Rotate 90 to mount. 14 Series PSE Specific Product Precautions 3 Be sure to read before handling.

Note) Refer to page 17-3-14 Applicable Fluids Check List for details of special fluids outside of the standard options and specifications.

14 Circulating fluid pressure [MPa] Circulating fluid pressure [MPa] Outlet: 60 Hz Outlet: 60 Hz 0.12 0.12 12 12 0.10 0.10 Pump head [m] Pump head [m] 10 10 0.08 0.08 8 8 Outlet: 50 Hz Outlet: 50 Hz 0.06 0.06 6 6 0.04 0.04 4 4 Allowable operating range Allowable operating range Return port Return port 0.02 0.02 2 2 0.00 0.00 0 2 4 6 8 10 12 14 16 0 2 4 6 8 10 12 14 16 Circulating fluid flow

63 35 32 27 38 20 16.5 32 2 14 14 58 11 45 59 72 M10 x 1.5 depth 16 to 1400 80 40 37 32 50 25 19 40 3 20 20 71 13 53.5 68 89 M10 x 1.5 depth 22 to 1500 100 40 37 41 60 30 20 50 3 20 20 71 16 64.5 79 110 M12 x 1.75 depth 22 Bore size (mm) K KA MM MO NA P RF S TA TC TDH9 TE TF TG WL ZZ 20 +0.08 0 5 6 M8 x 1.25 15 24 1/8 11 81 11 M5 x 0.8 8 4 0.5 5.5 15 118 25 5.5 8 M10 x 1.25 15 29 1/8 11

Max. load mass Review M1, M2, M3. M max is the allowable moment. 2 = M/M max 2. Static moment Review Me1, Me3. Me max is the allowable moment. 3 = Me/Me max 3.

12.5 21.5 19 22 19 19 16 16 14 6 5 7.6 depth 6.5 81 72.5 86 77.5 91 82.5 96 87.5 101 92.5 106 97.5 116 126 100 88.5 93.5 103.5 108.5 135 145 40 36.5 110 98.5 113.5 9.5 depth 8 105 115 120 125 83 88 93 98 103 108 118 128 106 111 116 121 126 131 141 151 5.5 9 4.5 20 25 15.5 18 32 50 10 29 40.5 M8 x 1.25 9.5 depth 9 22 22 23 20 8 748

Nomihal diameleri 3mm 41-140.F (5-60.C) Non-lube Not available Male thfead (srd.)

Tightening of M3 and M5 screws 1) M3 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2. After tightening by hand, the barb elbow type should be tightened by an additional 1/2 rotation using an appropriate wrench. 2) M5 1.

Terminal cover Round head combination screw M3 Tightening torque 0.5 to 0.6 Nm A G 1/2 Tightening torque 0.5 to 0.6 Nm + Mark Mark 2 1 + A Round head combination screw M3 tightening torque 0.5 to 0.6 Nm Conduit terminal View A-A (Internal connection diagram) 16-8-20 21 Series ISA2 Specific Product Precautions 3 Be sure to read before handling. 2 Port Solenoid Valve Series VCA Regulator Series