l H R port lpE port M:Common exhaust for main and pilot valve M5:10-32 with Nom.
B: Locking slotted type 4 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 10 5 6 24 VDC 12 VDC 240 VAC 50/60 Hz 7 15 2 9 Other Nil: Non-locking push type 20 3 Option Valve size 5 to 7 25 4 1 1 1 2 32 5 1 4 1 2 40 50 6 7 Note) Air operated only Electrical entry/ With light/surge voltage suppressor E GS G Grommet with surge voltage suppressor Grommet Grommet
VK300-82-2-01 VK300-82-2-03 110 VAC 110V VK300-82-2-02 200 VAC 200V VK300-82-2-04 220 VAC 220V 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 DIN terminal type Indicator light (Built-in connector) Marking Circuit with indicator light AC circuit diagram 12 VDC or less circuit diagram 24 VDC or more circuit diagram
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
VK300-82-2-01 VK300-82-2-03 110 VAC 110V VK300-82-2-02 200 VAC 200V VK300-82-2-04 220 VAC 220V DIN terminal type VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD Indicator light (Built-in connector) Marking Circuit with indicator light AC circuit diagram 12 VDC or less circuit diagram 24 VDC or more circuit diagram
63.5 15 55 13 36.5 15 M8 x 1.25 13 8 30 32 63.5 Metal cover type Leave sufficient space to open and close the metal cover when operating the manual release.
) 36) 32) () 10m IP65 LEC-MR-J3BAT DC24V LE-CNP3 1. 3.5kW5kW 11 3 11 No.
insulation type 1 W DC (42 mA), 0.5 W DC (21 mA) (4) 24 VDC Power consumption (Current) 1 W DC (83 mA), 0.5 W DC (42 mA) (4) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 12 VDC Metal seal Rubber seal Note 1) Use dry air to prevent condensation when operating at low temperatures.
(such as static electricity. (2) Check if the power supply voltage System error is in the range 24 VDC 10%. (Er0, 4, 6, 7, 8 or 9) is displayed. (2) Supply power in the range 24 VDC 10%. HHH is 6 displayed. (1) Reset applied pressure (1) Check that the pressure is not to a level within the set pressure range.
Response Frequency 100Hz (10ms) Operating Temperature Range 0~500C (air should not be frozen) / 32~120F Temperature 25+-10 0C +-0.3% F.S. or less Characteristic* 0-500C /32~120F +-0.5% F.S. or less Repetition Accuracy +-0.2% F.S. or less Noise Resistance 500Vp-p pulse width 1s standing 1ns Withstand Voltage Between whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance
+20%, 15%/6 A US2 24 VDC +20%, 15%/4 A Output type Source/PNP (Negative common) Number of outputs 32 outputs Load Solenoid valve with surge voltage suppressor of 24 VDC, 1 W or less (SMC) Power supply 24 VDC, 2 A Protection Short-circuit protection Output EX245-SPN1 Max. number of modules 8 Max. number of digital inputs 128 Max. number of digital outputs 64 Weight 1000 g 1 The conguration
(such as static electricity. (2) Check if the power supply voltage System error is in the range 24 VDC 10%. (Er0, 4, 6, 7, 8 or 9) is displayed. (2) Supply power in the range 24 VDC 10%. HHH is 6 displayed. (1) Reset applied pressure (1) Check that the pressure is not to a level within the set pressure range.
(such as static electricity. (2) Check if the power supply voltage System error is in the range 24 VDC 10%. (Er0, 4, 6, 7, 8 or 9) is displayed. (2) Supply power in the range 24 VDC 10%. "HHH" is 6 (1) Reset applied pressure displayed. (1) Check that the pressure is not to a level within the set pressure range.
N.O. 1/4 to 2 32 A to 50 A 10 to 50 N.C. N.O. 1/4 to 1 32 A to 50 A 10 to 50 Series VXA21/22, VXA31/32 Series VNC For Air, Vacuum, Water, Oil Air Operated 2/3 Port Valve Cutting Oil, Coolant for Machine Tool, etc. Coolant Valve Valve type Port size Body Seal Cast iron NBR N.C. N.O. C.O. Valve type Model Port size Body Seal N.C.
Ambient temperature Sensor section: 32 to 302F [0 to 150C] Amplifier section: 32 to 140F [0 to 60C] Most sensitive position 7 40 Impact resistance Sensor section: 1000 m/s2 Amplifier section: 300 m/s2 3000 Standards CE marking, RoHS Applicable Cylinder Cylinder with Heat Resistant Auto Switch: -XB14 (Made to Order) Series Description Model Action Applicable bore size [mm] Note 16 20 25 32
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 28 23.5 30 Piping adapter AC25, AC30 AF30, AR30, AW30 AL30, AFM30, AFD30, AWM30, AWD30 30 30 32 AC40 AF40, AR40, AW40 AL40, AFM40, AFD40 AWM40, AWD40 36 36 32 AC40-06, AF40-06, AR40-06, AW40-06 AL40-06, AFM40-06, AFD40-06 E500-06 44 40 32 3/4 E600-06
D-A93 D-M9B D-M9N Load voltage 24 VDC 28 VDC or less 24 VDC (10 to 28 VDC) Load current range Indicator light 5 to 40mA (24 VDC) 40mA or less 5 to 40mA Relay, PLC IC circuit, Relay, PLC 24 VDC Relay, PLC PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.