D-R732C R73C Relay 24 VDC 5 to 40 mA PLC Relay 24 V AC/DC or less 50mA D-R801 D-R802 R80 PLC 48V AC/DC 40mA D-R8 IC circuit 100V AC/DC 20mA D-R801C D-R802C R80C Relay 24V AC/DC 50mA PLC D-S7 D-S791 D-S792 S79 28 VDC or less 40mA or less Relay D-S7P1 D-S7P2 S7P 80mA or less PLC D-S9 D-S991 D-S992 S99V S99 28 VDC or less 40mA or less IC circuit D-S9P1 D-S9P2 S9PV S9P 80mA or less D-T7 D-T791
[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
Measure the voltage at both ends of the solenoid valve power supply and check if the voltage is within the specified range. 24 VDC +10/-5 Investigate the cause of voltage fluctuation and fix the problem. -29No.EX-OMO0004-D Specifications Table of Specifications General specifications Item Specifications Rated voltage 24 VDC Power supply voltage range Communication power supply for DeviceNetTM
How to Order Needle Valve/Flow Rate Characteristics 0 2 F A 1 AS 1 M3 X790 06 AS1201F-M350 45 40 35 30 25 20 15 10 5 0 0.5 0 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 Inlet pressure: 0.5 MPa Port size Push-lock type Body size Flow rate [L/min (ANR)] 1 M3 x 0.5 M3 M3 x 0.5 Applicable tubing O.D.
Description Size Quantity BBA2 1 Auto switch mounting screw M3 x 0.5 x 6 L 1 BMU1-025 M3 x 0.5 x 8 L 1 BQ-1 M3 x 0.5 x 10 L 1 BQ-2 2 Auto switch mounting nut (Hexagon nut) M3 x 0.5 1 BQ-1 3 Auto switch mounting nut (Convex shape) M3 x 0.5 1 BQ-2 D-A7, A8 D-F7, J7 * A spacer for BQ-2 (black resin) is not included. * When using D-A9l(V)/M9l(V)/M9lW(V)/M9lA(V) auto switches with BQ2-012, use
(Example) SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
For details, refer to the MXQR Operation Manual. 2 7 J I 3.5 6.5 3.5 6.75 3 depth 3 +0.03 0 3 depth 3 +0.03 0 4 N x M3 x 0.5 thread depth 5 6.5 3.5 0.7 16 1 17 15 36 24 16 1 32 12 F 5 4 x M3 x 0.5 thread depth 4 10 -1 x F 2 N 12 3 x M4 x 0.7 thread depth 6 M 6 KA 14.6 7 3.8 NA x M3 x 0.5 thread depth 3.5 K 14.6 Bottom view of MXQR8-30 7 3.8 14 21.2 0.3 27 23 6 4 23 Z ZZ (NN-1) x H G H 13.5
With brake: 148 Without brake: 118 Housing With brake: 135 Without brake: 105 29 24.6 Thread size M3 x 0.5 6 4 45 M4 x 0.7 8 2 46 Effective thread length (mm) Quantity P.C.D.
Electrical specifications Item Specifications Current consumption of controller power supply 21.6 to 26.4 VDC 0.1 A max.
Supply 15 to 30 VDC to the power supply for communication. Check the power supply for communication voltage.
When auto tuning mode 1,2 and interpolation mode is selected, the result of auto tuning is automatically used. 33.7 ms 0.1 to 1000.0 PB11 VDC Speed differential compensation Used to set the differential compensation.
When auto tuning mode 1,2 and interpolation mode is selected, the result of auto tuning is automatically used. 33.7 ms 0.1 to 1000.0 PB11 VDC Speed differential compensation Used to set the differential compensation.
VX021S-1-16FB 12 VDC 100 VAC 110 VAC 200 VAC C18312G6GCU None 220 VAC 230 VAC 240 VAC 24 VAC 48 VAC 24 VDC GDM2A-L5 12 VDC GDM2A-L6 100 VAC GDM2A-L1 110 VAC GDM2A-L1 200 VAC GDM2A-L2 220 VAC GDM2A-L2 230 VAC GDM2A-L2 240 VAC GDM2A-L2 24 VAC GDM2A-L5 48 VAC GDM2A-L15 With light * Select an appropriate DIN connector suitable for the coil insulation type. 7 XSA Series Specific Product Precautions
x 0.5 9.5 3.4 6.5 3.3 5 7 5.5 10.5 26 23 34 15 7.5 M3 3.5 10 M3 x 0.5 11.5 3.4 6.5 3.3 5 7 7 13 33 30 38 15 7.5 M3 3.5 12 M4 x 0.7 18 4.5 8 4.4 4.5 6.5 7.5 14.5 38.5 35.5 53 17 8.5 M4 4.5 14 M4 x 0.7 16.5 6 4 45 14 62 29 14.5 M3 4.5 26 6.5 7 34 3 M5 x 0.8 20.5 7 4 51 17 70 29 14.5 M4 5.5 31 8 8 39 3 M6 x 1 21 7.5 4.5 62.5 22 76 34 17 M5 6.5 41 9.5 10 50 3 M6 x 1 25.5 7.5 7.5 74.5 28 90 39
IDFB Corrected air flow capacity = 31 m3/h (0.83 x 0.83 x 0.92) = 48.9 m3/h Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air consumption (Correction factor A x B x C) IDH 3 ID Select the model. According to the corrected air flow capacity of 48.9 m3/h, the IDFA8E will be selected when the required output air pressure dew point is 3C.
: 50mA 48VAC or VDC: 40mA 100VAC or VDC: 20mA IS1000E-3004 IS1000E-4002 Note 2) AC40 AR40, AW40 AWM40, AWD40 IS1000E-4003 12.5 37 62.5 32 80.5 IS1000E-4004 Max. operating current IS1000E-4006 Note 1) in the model numbers indicates a thread type.
Electrical entry Lateral Lateral Lateral 2-wire 3-wire Wiring type NPN Type PNP Type Output type 24 VDC relay, for PLC IC circuit, Relay, for PLC Applicable load 5, 12, 24 VDC(4.5 to 28V) Power supply 10mA or less Current consumption 28 VDC or less 24 VDC(10 to 28 VDC) Load voltage 2.5 to 40mA 40mA or less Load current 4V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal