terminal and for sensor + 24 VDC) 17 V or greater/2.5 mA or greater (Between input terminal and for sensor 0 VDC) 7 V or less/1 mA or less (Between input terminal and for sensor + 24 VDC) ON voltage/ON current 7 V or less/1 mA or less (Between input terminal and for sensor 0 VDC) OFF voltage/OFF current Display Green LED (illuminated when turned ON) Enclosure IP10 10 to 50C Operating temperature

(A) 4 (B) 2 FPG 1 (P) 5 (R1) 3 (R2) Coil rated (A) 4 (B) 2 1 2 3 4 9 100 VAC 200 VAC 24 VDC 12 VDC FIG 1 (P) 5 (R1) 3 (R2) Other voltages Option For other voltages, please contact SMC separately.

Proper use of the seal cap enables the enclosure to achieve IP67 specification. -30No.EX-OMN0030-D Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug Power Power supply (Control and input) 24 VDC 10% Class2, 2 A 24 VDC 10%, 8 A Power supply (Output) 24 VDC +10/-5% Class2, 2 A 24 VDC +10/-5%, 8 A Enclosure IP67 (With manifold assembled

Metal ( shaded) part Metal ( shaded) part Tap for ground wiring Resin part ( shaded) 454 Ionizer IZN10 Series Power Supply Cable Connection Circuit NPN PNP Ionizer Ionizer IZS Brown +24 VDC Brown +24 VDC +24 V +24 V Power supply 24 VDC 10% 0 V +24 V Power supply 24 VDC 10% 0 V +24 V Blue 0 V Blue 0 V IZN IZN INPUT PLC OUTPUT OUTPUT PLC INPUT IZF Orange Discharge stop signal Orange Discharge

insulated from each other. 24 VDC ML2B 24 VDC C J G5-S Electrical Wiring CV The position detection sensor of the stroke reading cylinder outputs an A/B phase difference (open collector output) as shown in the diagram below.

insulated from each other. 24 VDC ML2B 24 VDC C J G5-S Electrical Wiring CV The position detection sensor of the stroke reading cylinder outputs an A/B phase difference (open collector output) as shown in the diagram below.

+20%/-15% Under voltage detection Detected: < approx. 19 VDC Under voltage lockout < approx. 16 VDC PWR For logic Over voltage detection > approx. 33 VDC Over voltage lockout (fuse blown) > approx. 40 VDC Internal current consumption at 24 VDC 0.2 A or less Operating voltage 24 VDC +20%/-15% Under voltage detection Detected: < approx. 19 VDC Under voltage lockout < approx. 16 VDC PWR(V)

Hysteresis 4 Variable Protection Short circuit protection Voltage input: 1 to 5 VDC, 0 to 10 VDC (only when the power supply voltage is 24 VDC) 6 Output type Current input: 4 to 20 mA Analogue output 5 (0 L/min to max. value of the rated flow) Impedance Voltage output Output impedance approx.: 1 k Current output Max. load impedance: 300 at 12 VDC, 600 at 24 VDC Response time 2 50 ms or

Indicator light Output 1 and 2: Orange Power supply Used as switch output device 12 to 24 VDC, including ripple (p-p) 10% voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 50 mA max.

Ion generation stars by disconnecting PNP specification: Ion generation is stopped by connecting to 24 VDC .

Proper use of the seal cap enables the enclosure to achieve IP67 specification. -28No.EX-OMS0027 Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug Power Power supply (Control and input) 24 VDC 10% Class2, 2 A 24 VDC 10%, 8 A Power supply (Output) 24 VDC +10/-5% Class2, 2 A 24 VDC +10/-5%, 8 A Enclosure IP67 (With manifold assembled

Proper use of the seal cap enables the enclosure to achieve IP67 specification. -22No.EX-OMQ0016 Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug Power Power supply (Control and input) 24 VDC 10% Class2, 2 A 24 VDC 10%, 8 A Power supply (Output) 24 VDC +10/-5% Class2, 2 A 24 VDC +10/-5%, 8 A Enclosure IP67 (With manifold assembled

For manifold type 30, 31 VP Standard type (Cv: 0.008) SY1 3 5 L 1 M3 : Body ported VG VP Standard type (Cv: 0.008) 5 1 SY1 4 M : Base mounted S070 3 port VQ Port size Rated voltage For DC Nil: Without sub-plate M3: With sub-plate VKF 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC VQZ VZ Sub-plate style For manifold type S41 For AC (50/60 Hz) 1 2 3 4 100 VAC 200 VAC VS (With gasket and screws)

This SI unit has IP65 protection rating. 29 Supported Protocols DeviceNetTM 11 to 25 VDC (without sensors) Supply Voltage 20 to 25 VDC (with sensors) Current Requirement 0.5A maximum Serial Unit Inputs 32 points Click here for more information Outputs 16 points Dimensions 167W x 57H x 71D Input voltage 10 to 26.4 VDC Solenoid Outputs Power handling 2.8W maximum Input voltage 20 to 25 VDC

ELECTRICAL CHARACTERISTICS Coil Voltage: 5 to 825 VAC, 50-60 Hz. 1.8 to 265 VDC OPERATING CONDITIONS Media: Air and other non-corrosive gases, water and oil. Filtration: Down to 60 microns or less is recommended.

ELECTRICAL CHARACTERISTICS Coil Voltage: 5 to 825 VAC, 50-60 Hz. 1.8 to 265 VDC OPERATING CONDITIONS Media: Air and other non-corrosive gases, water and oil. Filtration: Down to 60 microns or less is recommended.

The product Ground terminal +24V Brown +24 VDC +24V Blue 0V Power supply 0V 24 VDC F.G. Be sure to ground.

(Error number 5) Vs : Power supply 24 VDC A : Input signal 4 to 20 mA DC 0 to 20 mA DC Vs : Power supply 24 VDC Vin : Input signal 0 to 5 VDC 0 to 10 VDC 4 points preset input type Brown Blue S1 White Vs Black S2 Vs: Power supply 24 VDC (Negative common) One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.

LEF Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular LEJ LEJ Wiring type 2-wire 3-wire NPN PNP Output type LEL Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) LEM Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC