SMC Corporation of America
Elite Part Number Search
Search Results "RZQL32-200-140"

1 1/2 Short 0.63 to 1.95 26 52 140 125 2 Middle 0.34 to 1.06 23 45 IF IF31-10 280 250 2 1/2 Middle 0.41 to 1.29 45 90 Data 250 220 3 Middle 0.26 to 0.81 40 80 550 480 4 Long 0.33 to 1.05 85 170 Long 1,000 870 5 0.37 to 1.24 150 300 Long 1,500 1,300 6 0.40 to 1.32 230 460 110 100 1 Short 1.00 to 3.05 18 36 160 140 1 1/4 Short 0.90 to 2.67 27 54 270 230 1 1/2 Short 1.10 to 3.29 45 90 270 230

14 ' 140"F {-10-+60'C} 2 16 inlsec {50-400mn/s} Urethane cushion at both sides [lax. operating pressure Min. operating pressure Ambient and fluid temperature Operating piston speed Cushion Lubrication Stroke tolerance 0-9.gstlb6s, 10-39.4st: tbs, 39.sst-:13?

ZFA100 Port size Symbol Model A B 18 20 28 ZFA200 1 8 1 4 Manifold Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 ZFA200 1 8 1 4 Number of manifold stations Symbol Single unit Note) Model 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10

F(N) F(N) Stroke 105 15 9 110 115 14 120 8 125 130 13 140 150 7 12 175 5 200 11 0 1 2 Rotation angle Linear motion Number of Auto Switches Mounted 02 0S 0 S2 SS S0 1 Nil 2S 20 2 n2 nS n0 n Combinations of made-to-order products No. 1 to 4 are available. Please contact SMC for further information. 11-10-19

Made to Order How to Order 2 F 06 A 200 AS Lubricant: Vaseline -X12 Example) AS2002F-04A-X12 Body size Made to Order Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Push-lock type Example) AS2002F-04A-X21 * Not particle-free Applicable tubing O.D.1 Metric size Inch size 23 3.22

(ON ON ON (LED)No.10() Err9 (P3)(P2) () Err9 Err9 ON ON ON ()5mm Err5 5mm 1 Err10: Err11 CPU Err12 ON 13-2 () 200 200 ( 6) 57 *200.0 PRG STEP P6 200.0 200 200 300mm/sec 50% 35% 58 141 No. No.

SUP = 0.2 MPa 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 50 100 150 200 0 Discharge (mL/min) 0 Discharge (mL/min) 200 400 600 800 1000 0 Discharge (mL/min) 200 400 600 800 1000 Air Consumption: Built-in Solenoid Valve/Air Operated Calculation of Air Consumption Air Consumption 45 Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of 0.35 MPa from the air consumption

VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.

Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 1 8 1 4 ZFA200 L1 1 Number of manifold stations Model Symbol 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10 200 212 300 312 38 50 48 60 ZFA100 L2 L1 L2 ZFA200 13-10-3

Mounting: Both Ends Tapped, Bore Size: 50mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 140mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

500 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [L/min (ANR)] IW215 Flow rate characteristics IW222 Flow rate characteristics Supply pressure: 0.7 MPa 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 100 300 400 200 600 500 Supply pressure: 0.5 MPa 0.25 0.2 Set pressure [MPa] Set pressure [MPa] 0.15 0.1 IP 0.05 IW IW 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [

Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Terminal block Recommended earth leakage breaker screw Recom Tightening Model Power supply Cable qty. x torque Rated Sensitivity Rated diameter mended voltage size voltag of leak current crimp e current [A] terminal [V] [mA] 3coresx12AWG 1-phase (3 cores 200-230V AC HRS050-A-20 200, x3.5mm2) (including 230 20 30 M4 5.5-4 1.5Nm

SUP = 0.2 MPa 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 50 100 150 200 0 Discharge (mL/min) 0 Discharge (mL/min) 200 400 600 800 1000 0 Discharge (mL/min) 200 400 600 800 1000 Air Consumption: Built-in Solenoid Valve/Air Operated Calculation of Air Consumption Air Consumption 45 Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of 0.35 MPa from the air consumption

300 200 600 500 250 150 Flow rate 100 L/min type Note 1) 24 VDC, Duty ratio 1:1 80 W: Current needs to be limited by using an energy saving driver circuit. 40 W: Current needs to be limited by using an energy saving driver circuit. 10 W: Energizing time is one second at a maximum.

Bore) BT-16 (160 Bore) BT-18 (180 Bore) BT-20 (200 Bore) our new part # C95D Tie Rod Mounting BT-03 (32/40 Bore) BT-05 (50/63 Bore) BT-06 (80/100 Bore) -F5PSDPC NCDA1 Tie Rod Mounting NBT-150 (1.5" Bore) NBT-200 (2" & 2.5" Bore) NBT-325 (3.25" & 4" Bore) "SC" auto switch CDQ2/NCDQ Direct Body Mount BQ-2 (32/40/50/63/80/100 Bore) Screw & Nut Kit included with cylinder "SC" auto switch CDRA1

Ordering example (Example) Series VXP22, 32A Flange, 200 VAC, DIN terminal (Part no.) VXP2272-32-2D Made to Order Specifications Splashproof Specifications ( ) Based on JIS C 0920 Based on IEC529IP-X4 VXP Model Port size Electrical entry X36 DIN terminal or class H coil not available. 17-3-47 6 The VX series will be revised shortly.

million cycles VQC2100: 20 ms 2 ms; 200 million cycles VQC4100: 17 ms 3 ms; 100 million cycles '-t t iS nge mounting screw Avai abe configurations lN.C.

VCHC ASR ASQ ASD230F ASD330F ASD430F 100 200 400 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 07,08,09,10,11 300 06 200 50 100 100 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530F ASD630F 1500 1000 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 12 10,11 10,11,12 08,09 1000 500 06,07 500 0 5 10 0 5 10

thread) Valve sizes 2 to 4: VN-16 Nil F N T A B C NBR seals FKM seals EPR seals Nil B Note) None With bracket Refer to Table (1) for availability. 2 0 1 A VNA Air operated 15A 2 to 4 External pilot solenoid 2 VNA 1 1 A 15A 1 T CE-compliant Nil Q CE-compliant Note) CE-compliant: For D or DZ only Manual override Rated voltage Valve size Valve type Port size 3 Note 2) 2 1 110 VAC 50/60 Hz 200