0.2 MPa 300 0.2 MPa 160 80 120 200 80 40 100 40 40 120 100 80 60 180 140 100 60 240 200 160 120 80 Point of application L (mm) Point of application L (mm) Point of application L (mm) D-X Individual -X 1421 Escapements Series MIW/MIS 8, 12, 20, 25, 32 How to Order Finger options Nil: Basic type (Standard type) 1: Tapped on upper and lower faces 2: Tapped on all faces (5 surfaces including
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Mounting Bolt for C55 Model C D Mounting bolt Model C D Mounting bolt Model C D Mounting bolt M8 x 70 l x 75 l x 80 l x 85 l x 90 l x 95 l x 100 l x 105 l x 110 l x 120 l x 140 l x 160 l M4 x 45 l x 50 l x 55 l x 60 l x 65 l x 70 l x 75 l x 80 l x 85 l x 90 l M5 x 55 l x 60 l x 65 l x 70 l x 75 l x 80 l x 85 l x 90 l x 95 l x 100 l x 110 l x 130 l x 150 l 70 75 80 85 90 95 100 105 110 120
The spacing of the side support must be no more than the values shown in the graphs at right. 200 200 190 190 (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) (2400) 130 130 l (1800) (1800) (1800) 120 120 Weight m (kg) Weight m (kg) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) 90 90 (1500) (1500) (1500) MY1CW63 MY1CW63 m 80 80
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Page 120 Options With Caster Adjuster-foot . Page 111 With Earth Leakage Breaker . Page 111 With Earth Leakage Breaker with Handle . Page 111 With Fluid Fill Port .
0.2 MPa ML2B 300 0.2 MPa 160 C J G5-S 80 120 200 CV 80 40 MVGQ 100 40 CC 40 120 100 80 60 180 140 100 60 240 200 160 120 80 RB Point of application L (mm) Point of application L (mm) Point of application L (mm) J D-X 20Data 10-11-7 7 Escapements Series MIW/MIS 8, 12, 20, 25, 32 How to Order Finger option Nil: Basic type (Standard) 1: Tapped on upper and lower faces 2: Tapped on all faces
250 262.5 275 148 160.5 160.5 173 185.5 185.5 198 210.5 210.5 223 235.5 235.5 248 260.5 260.5 273 285.5 L n 21 22 23 24 25 26 27 28 29 30 31 32 19 20 L1 L2 L3 L4 216.5 225 233.5 242 250.5 259 267.5 276 284.5 293 301.5 310 199.5 208 272.2 280.7 289.2 297.7 306.2 314.7 323.2 331.7 340.2 348.7 357.2 365.7 255.2 263.7 300 312.5 312.5 325 337.5 337.5 350 362.5 362.5 375 387.5 387.5 275 287.5
(Displays 0 when the value is below 50 L/min) 120 to 2100 L/min 60 to 1050 L/min (Displays 0 when the value is below 120 L/min) 6.0 0 to 6%F.S. (Displays 0 when the value is below 60 L/min) 140 to 2100 L/min 70 to 1050 L/min (Displays 0 when the value is below 140 L/min) 7.0 0 to 7%F.S.
Accessories (Options) Applicable model Bracket assembly AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Symbol BM51 BM52 BM53 BM54 BM55 BM56 BM57 spring washer With cap bolt, AMF Refer to ''Precautions" on p.4.6-33. 4.6-27 Odor Removal Filter Series AMF AMF150 to AMF850 How to Order AMF 250 03 R B Option R IN, OUT reversal Body size Accessories (Optional) 150 1 8 250 1 4 350 3 8 450 1 2
(mm) Connection threads R Model M Effective area (mm 2) Weight (g) A L1 L2 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 DT04-01 15 5.7 33 DT04-02 17 19 4 10 19.6 10 23.5 40 2-applicable tubing DT06-01 35 17 19.6 10 23.5 DT06-02 16 6 19 44 14 14 12 DT06-03 22 70 26.5 24.5 21.6 22.6 24.5 25.8 24.5 29.4 29.6 30.3 29.4 120 Reference dimensions after R thread installation.
.> 140 Air consumption l/min (ANR) 120 SUP=0.5MPa 100 Note 1) If the discharge pressure is required instead of the total lifting height, a total lift of 10m corresponds to a discharge pressure of 0.1MPa. SUP=0.3MPa 80 SUP=0.2MPa 60 Note 2) 1 cycle discharge rate PA3000: Approx. 22ml PA5000: Approx. 100ml Selection procedure 1.
and enclosure 10 to 500 Hz with 1.5 mm amplitude or 98 m/s2, whichever is smaller 980 m/s2 in X, Y, Z directions 3 times each (Not energized) 3% F .S. or less of measured pressure at 25C in temperature range of 0 to 50C Pressure receiving area: Stainless steel 630, Fittings: Stainless steel 304 02: R 1/4, M5 x 0.8 T2: NPT 1/4, M5 x 0.8 5-wire oil proof heavy-duty cable (0.15 mm2) Approx. 120
F MXZ12 MXZ16 160 100 OUT side IN side OUT side IN side 140 0.7/ 80 0.7/ Supply pressure [MPa] Supply pressure [MPa] 120 Pressing force [N] Pressing force [N] 100 0.5/0.67 60 0.5/0.67 80 40 0.3/0.4 0.3/0.4 60 40 20 20 0 0 0 20 40 60 80 0 10 20 30 40 Allowable overhang L [mm] Allowable overhang L [mm] MXZ25 MXZ20 400 250 OUT side IN side OUT side IN side 350 0.7/ 0.7/ 200 Supply pressure [
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 l/min (ANR) IR1000-01 IR1000-01 IR1000-01 Back pressure: 0.5 MPa Supply pressure: 0.5 MPa 0.5 0.204 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) 0.4 ARJ 0.202 0.15 Set point AR425 to 935 0.3 0.200 0.1 0.2 AMR 0.198 0.05 0.1 ARM 0.196 ARP 0 40 20 80 60 100 140 120 0 50 100 200 250 150 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8
Station 2 58 40 Station 20 346 328 Station n L1 L2 3 74 56 4 90 72 5 106 88 6 122 104 7 138 120 8 154 136 9 170 152 10 186 168 11 202 184 12 218 200 13 234 216 14 250 232 15 266 248 16 282 264 17 298 280 18 314 296 19 330 312 39 Series SYJ5000 [ ]: AC Type 40: Bottom Ported/SS5YJ5-40Stations -M5 Grommet (G) Approx. 300 (Lead wire length) 9 L2 L1 4-4.5 (For mounting) 13 36.9 (DIN 38.1) 21.5
.> 140 Air consumption l/min (ANR) 120 SUP=0.5MPa 100 Note 1) If the discharge pressure is required instead of the total lifting height, a total lift of 10m corresponds to a discharge pressure of 0.1MPa. SUP=0.3MPa 80 SUP=0.2MPa 60 Note 2) 1 cycle discharge rate PA3000: Approx. 22ml PA5000: Approx. 100ml Selection procedure 1.
.> 140 Air consumption l/min (ANR) 120 SUP=0.5MPa 100 Note 1) If the discharge pressure is required instead of the total lifting height, a total lift of 10m corresponds to a discharge pressure of 0.1MPa. SUP=0.3MPa 80 SUP=0.2MPa 60 Note 2) 1 cycle discharge rate PA3000: Approx. 22ml PA5000: Approx. 100ml Selection procedure 1.
Full stroke Note 1) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 Bore size (mm) Note First-stage stroke Note 2) 5 mm to "Full stroke" 5 mm Note 1) RZQB (through hole type) is only available for full strokes 25, 50 and 75. Note 2) Available in 1 mm increments.
Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR) Supply pressure: 0.5 MPa IR1000-01 IR1000-01 IR1000-01 Back pressure: 0.5 MPa 0.5 0.204 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) Set pressure (MPa) 0.4 0.202 0.15 Set point 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 40 20 80 60 100 140 120 0 50 100 200 250 150 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8