200 Flow rate [L/min (ANR)] 0 50 100 Flow rate [L/min (ANR)] AFM30-D AFD30-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.3 MPa 0.01 0.01 P1 = 0.7 MPa P1 = 0.7 MPa 0 0 0 100 200 500 400 300 600 0 150 100 50 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-D AFD40-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1

) 02 01, 23 79.3 13.2 03, 04 (300) (50) 26.5 52.8 (100) (200) 26.4 (100) 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.

Base Mounted Bore size Series CJ2 Pressure 73 psi (0.5 MPa) Load factor 50% Stroke 60 mm Series CM2 Pressure 73 psi (0.5 MPa) Load factor 50% Stroke 300 mm Average speed mm/s Series 6 10 16 20 25 32 40 800 Perpendicular, upward actuation Horizontal actuation 700 600 500 S0715-5G-M5 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which

Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to

Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to

Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.

100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply

Cylinder stroke (mm) Long stroke (mm) 35, 40, 45, 50, 75, 100 Bore size (mm) Standard stroke (mm) 5, 10, 15, 20, 25, 30 Action D Double acting 12, 16 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches/Refer to p.5.3-2 for further information on auto switch.

0.5 s 1 s 1.5 s 2 s 2.5 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 3) Supply pressure: 0.2 MPa Flow rate consumption: 188 L/min (ANR) 4) Supply pressure: 0.3 MPa Flow rate consumption: 253 L/min (ANR) 200 200 150 150 2.5 s 2 s 100 100 50 50 0.5 s 1 s 1.5 s 2 s 0.5 s 1 s 1.5 s 50 50

/60 Hz 200 VAC 50/60 Hz 110 VAC [115 VAC] 50/60 Hz 220 VAC [230 VAC] 50/60 Hz 24 VDC 12 VDC Note 1) Refer to the below table (1) for combinations with light/surge voltage suppressors.

100 VAC, 50/60 Hz 200 VAC, 50/60 Hz Nil N T F Standard Rc Nil Z None With light/surge voltage suppressor NPT 1 110 VAC, 50/60 Hz Option NPTF S With surge voltage suppressor 220 VAC, 50/60 Hz G 2 position double 5 6 9 24 VDC 12 VDC Note) Indicator light is not available for grommet type.

Model XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 Rated voltage for heater 90 to 240 VAC Heater assembly quantity 1 1 1 1 H4 100C 100 V 200/40 200/50 400/100 600/150 Heater assembly quantity used Heater power W (Nominal value) Inrush/Power consumption (Option symbol, Operating voltage) 200 V 800/40 800/50 1600/100 2400/150 Heater assembly quantity 1 1 1 1 2 H5 120C 100 V 200/40 400/70 400/

C2 LECSC2-T 200 to 230 2 2 S2 LECSS2-T 200 to 240 5 5 N2 LECSN2-T 200 to 240 A 10 E2 LECSN2-T-E 200 to 240 92 LECSN2-T-9 200 to 240 I/O cable length P2 LECSN2-T-P 200 to 240 Nil Without cable H Without cable Connector only 1 1.5 [m] Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 -9- AC servo motor LECY* series L E K F S

/60Hz) Single phase, 200/200 to 220VAC (50/60Hz) Single phase, 220, 240/200 to 240VAC (50Hz) Power source 225 275 205 240 182 189 250 350 220 280 265 275 305 380 300 350 280 295 340 415 325 375 332 50Hz 60Hz 50Hz 60Hz 50Hz 50Hz 50Hz 100 VAC 200 VAC Power consumption (W) 220 to 240VAC 220VAC 240VAC JIS Symbol 10 (for 100VAC), 5 (for 200VAC) Air cooled R134a Circuit breaker (A) Note 3)

VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation 10% 30 25 26 25 Refer to page 94.

11 57 248 30 18 53 33 1/2 191 67 +0.052 0 63 50 29 25 to 800 90 64.3 M27 x 2 80 12 M12 x 1.25 20 13 36 36 30 32 32 136 39 13 55 265 30 17 68 33 1/2 200 71 80 60 34 25 to 800 115 82.7 M33 x 2 93 15 M16 x 1.5 28 9 45 45 41 39 41 159 46 17 66 308 40 20 76 40 3/4 229 77 168 +0.062 0 100 72 50 130 96.9 M42 x 2 101 15 M16 x 1.5 25 to 1000 36 10 56 56 50 54 52 47 19 67 363 50 20 91 40 3/4 257 82

Maximum Allowable Moment MY1B/M1 MY1B/M2 MY1B/M3 200 300 400 500 40 50 100 30 200 20 50 40 30 100 10 20 40 50 3 4 5 30 10 20 Moment Nm Moment Nm Moment Nm 2 5 4 3 10 1 MY1B40 MY1B40 5 4 3 2 MY1B40 MY1B40 MY1B40 MY1B40 0.3 0.4 0.5 MY1B32 1 2 MY1B32 MY1B32 MY1B25 0.2 1 0.5 0.4 0.3 MY1B25 MY1B25 0.1 0.4 0.5 0.2 0.3 0.05 0.04 0.03 0.2 0.1 0.02 0.06 0.1 100 200 300 400 500 1000 1500 100 200 300

SY3120-C6 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5120-01 800 700 600 500 400 300 200 100 0 SY7120-02 800 700 600 500 400 300 200 100 0 SY9120-03 Base mounted Bore size Series CJ2 Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load rate: 50% Stroke 1000 mm 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 Series MB/CA2 Pressure 0.5 MPa Load

Bore size CJ2 series Pressure 0.5 MPa Load ratio 50% Stroke 60 mm CM2 series Pressure 0.5 MPa Load ratio 50% Stroke 300 mm CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] 6 10 16 125 140 160 180 200 250 20 25 32 40 40 50 63 80 100 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward