Relief type Vacuum suction type 1/8 25, 50, 75,100, 125, 150, 200 1/4 Not available 25, 50, 75, 100, 125, 150, 200, 250, 300 Non-lube Double acting, single rod Available Available 25, 50, 75, 100, 125, 150 1/8 25,50,75,100,125,150,200 1/4 25,50,75,100,125,150,200,250,300 Specifications Suction flow rate of vacuum suction type (Reference values) Bore size (mm) Item 20/25/32/40 2 Bore size
With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire D: With connector LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector H: Lead wire length 600 mm Type LN, MN: with 2 sockets.
, 300, 340 Reinforced pad to prevent deformation when transferring heavy or large work pieces How to Order ZP2 32 H N Pad unit Pad diameter Pad material Symbol Pad diameter 32 150 250 300 340 Symbol Material NBR Silicone rubber FKM CR N S F C 32 150 250 300 340 Note) Silicone rubber is only applicable to the 32 pad.
Data View A-A Mounting dimensions Bore size (mm) Stroke range (mm) N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA A 20 25 32 40 50 75, 100, 125, 150, 200 25 38 80 60 44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 32 46 95 70 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 75, 100 125, 150 200, 250 300 32 50 105 80 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 38 60 125 95
600 900 1200 Installation distance [mm] mm At maximum air flow (air flow scale: 4) 300 mm 300 0 4s 6s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm At minimum air flow (air flow scale: 1) 300 mm 300 6s 0 4s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm 18 - Doc. no.
Applicable Controller Power Supply Voltage 100VAC Specification Series LJ1H10 Series LJ1H20 LJ1H1021H-K (8mm lead) LJ1H2021F-K (5mm lead) 250 400 225 350 12kg 6kg 200 300 175 250 Speed (mm/s) Speed (mm/s) 150 8kg 13kg 125 200 10kg 100 150 14kg 75 100 15kg 50 50 25 0 100 200 Stroke (mm) 300 400 0 100 200 300 400 500 600 Stroke (mm) When an actuator is operated under conditions that exceed
Tube bore size B, #2(#2+#3) 40 125, 150, 175, 200, 250, 300 55 14 14 3.8-9 Series CXT Auto Switch Specifications Refer to p.5.3-2 for details on auto switch.
CXT Long Stroke (mm) X Y Z Stroke range (mm) Bore size (mm) CXSJ 32 125, 150, 175, 200, 250, 300 45.5 12.5 12.5 40 125, 150, 175, 200, 250, 300 55 14 14 CXS D-X Individual -X 529 Series CXT Minimum Stroke for Mounting of Auto Switch (mm) Application Auto switch model No. of auto switches mounted D-A9V D-A9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-M9 CXT12 1 10 10 5 15 20 5 to CXT25 2 10 10 10
QW RW T W X Y Z Bore size (mm) S 140 32 60 33 19 157 33 10.5 7.5 40 84 35 180 21 187 39.5 11 8 Long Stroke X Y Z Bore size (mm) Stroke range (mm) 32 125, 150, 175, 200, 250, 300 45.5 12.5 12.5 40 125, 150, 175, 200, 250, 300 55 14 14 8-27-9 10 Series CXT Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height Reed switch Solid state switch A B W D-A9 D-M9 D-F9BAL
L/min (PF3A706H) [6000] 6000 L/min (PF3A712H) [F 2] 2 [ 150] 150 L/min (PF3A703H) [H_2 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) [ 600] 600 L/min (PF3A712H) [dt2 ] Delay time setting [0.00] 0.00 s [CoL ] Select display colour [1SoG] Green when ON Red when OFF (OUT1) [F 3] [FiL ] Select digital filter [ 1.0] 1 second Page 44 [F 5] [FUnC] Select FUNC (switching analogue output/external
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
(Exception conditions: The inside diameter of the body is 150 mm or less.) Therefore, the KC Certification nameplate is not attached to the VBAT05A1-X101.
There are no flats on the E type 150 bore rear tang. Note 2) FF dimension for NCMC 150 is not applicable. There are no threads on the C type 150 bore rear tang.
VDW 2 0 1 C1 1 VC OUT (2) VDW Series Lead wire length 1 2 3 10 20, 200 30, 300 300 mm 600 mm Nil L1 (1) IN 2 Port Valve VQ Note) Note) Type L1 is optional.
HRS HRS 090 HRS 100/150 HRS 100/150 Part no.
140 160 45 50 55 60 65 70 75 80 85 90 55 60 65 70 75 80 85 90 95 100 110 130 150 C(D)55B20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B80-10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 C(D)55B40-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B50-5 -10 -15 -20 -25 -30 -35 -40
When you carry out adhesion mounting of the driver, make circumference temperature into 0 to 45 (32 to 113 ), or use it at 75% or smaller effective load ratio. 1000 1000 During operation During operation 100 100 Operation time[s] Operation time[s] During servo lock During servo lock 10 10 1 1 0.1 0.1 0 50 150 200 250 300 100 0 50 150 200 250 300 100 (Note) Load ratio [%] (Note) Load ratio
Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.