E N S I O N S A I R P I L O T O P E R AT E D T Y P E (N)VBA2200-03, (N)VBA4200-04 mm Model Port Size A B C D E F G H J K L (N)VBA2200-(N)03 38 300 126.5 53 118 98 44 45 60.5 18 15 (N)VBA4200-(N)04 12 404 167 96 150 130 62.8 62 90 17 15 40 Courtesy of Steven Engineering, Inc. !
150 0.3MPa 0.3MPa 200 200 0.3MPa 100 100 0.2MPa 0.2MPa 0.2MPa 0.2MPa 100 100 50 50 0.1MPa 0.1MPa 0.1MPa 0.1MPa 50 100 150 200 50 100 150 200 0 0 40 80 120 160 200 40 80 120 160 200 0 0 Holding point R (mm) Holding point R (mm) Holding point R (mm) Holding point R (mm) 2.2-3 Wide Opening Air Gripper Series MHL2 Example of Model Selection Procedures Check conditions Select possible points
S 6 50, 100, 150, 200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com "n" pcs. n 8 50, 100, 150, 200, 250, 300 12 50, 100, 150, 200, 250, 300, 350, 400 Auto switch type Nil Without auto switch Adjuster option Nil Rubber stopper B Shock absorber Metal stopper One
160.5 4 101.5 119 150 160.5 3 90 107.5 137.5 148 2 78.5 96 125 135.5 1 67 84.5 112.5 123 L1 L2 L3 L4 2-3-15 16 Series SQ1000 Kit (PC Wiring System compatible flat ribbon cable kit) J Manifold Specifications PC Wiring System compatible.
VS4 Standard Specifications VQ7 Compact yet provides a high flow capacity 1/4: C: 3.4 dm3/(sbar) Low power consumption: 1.8 W DC Fluid Air/Inert gas Maximum operating pressure Minimum operating pressure 1.0 MPa 0.1 MPa EVS Valve specifications Electricity specifications Ambient and fluid temperature 1.5 MPa Proof pressure VFN 10 to 60C (1) Non-lube (2) Non-locking push type (Flush) 150/50
Load (N) 0 50 100 150 Load (N) 0 50 100 150 Load (N) 200 16 16 16 L = 120 mm L = 120 mm L = 120 mm MXP16-20 MXP16-30 MXP16-20 MXP16-30 Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) 0.08 0.12 0.06 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.10 0.06 0.04 0.08 0.04 0.06 0.04 0.02 0.02 0.02 0 0 0 50 200 250 Load (N)
MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 20, 30, 40, 50, 75, 100 125, 150, 175, 200 M L MGQ 20, 25 MGJ MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 M L MGP MGQ OUT(N) IN(N) Theoretical Output (N) Bore size (mm) MGG Operating pressure (MPa) Rod size (mm) Operating direction Piston area (mm2) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 MGC Made to Order Specifications (For details
150 0.3 MPa 0.3 MPa 200 200 0.3 MPa 0.3 MPa 100 100 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80 120 160 200 Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) 476 Parallel Style Air Gripper: Wide Type Series MHL2 Model Selection Example Confirmation of conditions
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 11 For Water Digital Flow Switch Series PF2W Refer to www.smcworld.com for details of products compatible with overseas standards.
200 250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
350 kPa 150 kPa 350 kPa 150 kPa 350 kPa Flow [L/min] Flow [L/min] Flow [L/min] 150 kPa 750 kPa 750 kPa Number of needle rotations Number of needle rotations Number of needle rotations 14 PF2M7(-L) Series Flow Rate Characteristics at Negative Pressure (Reference Data) When the PF2M series is used with negative pressure (70 to 0 kPa), the measurable range (warranty range of the specifications
Load Blocking Mass and Center of Gravity for Each Workpiece 5 42.5 65 150 Center of gravity Mass mn Workpiece Wn Y-axis Yn X-axis Xn Z-axis Zn Z X Wa 0 mm 5 mm 0.88 kg 65 mm 111 210 Wb 0 mm 42.5 mm 4.35 kg 150 mm Y Y Wc 111 mm 42.5 mm 0.795 kg 150 mm Wd 210 mm 42.5 mm 0.5 kg 150 mm n = a, b, c, d 3.
VF (4(A), 2(B) port) 2n-Rc 1/8 VFR (Pitch) (Mounting hole) VP4 6-Rc 1/4 (1(P), 3/5(R) port) VZS VFS VS4 VQ7 EVS (Light/Surge voltage suppressor) Triangle mark VFN (Station n)(Station 1) Connector polarity indicator Applicable connector: 26 pins MIL (Conforming to MIL-C-83503) Built-in One-touch fittings (mm) Stations 4 5 108.5 109 12 272.5 252.5 L1 L2 3 88 68 129 109 6 149.5 129.5 7 170 150
Nil 6 50, 100, 150, 200 1 pc.
x 1.5 M18 x 1.5 300 800 1250 3100 0.5 0.5 0.75 1 5 Semi-standard/Thread nominal size 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 20 25 32 32/40 40 32/40 50 50/63 5 How to Order 14-150 JC 40 Thread
4-18-4.) 15 or less Max. operating frequency (Hz) 10 Non-locking push type, push-turn locking slotted type, push-turn locking lever type Manual override (Manual operation) Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Pilot exhaust method Body ported Lubrication Mounting orientation Shock/Vibration resistance (m/s2) Note 2) Not required Unrestricted 150
Igm: Leakage current of the servo motor (Found from Table 11.4.) 120 120 100 100 Leakage current Leakage current 80 80 60 60 40 40 [mA] [mA] 20 20 0 2 0 14 100 5.5 38 2 3.5 8 1422 38 80 150 5.5 30 60 100 3.5 8 22 60 150 30 80 Cable size[mm2] Cable size[mm2] a. 200V class b. 400V class Fig. 11.3 Leakage current example (lg1, lg2) for CV cable run in metal conduit 11 30 11.
end Shock absorber 10 20 30 40 50 75 100 125 150 Extension end Retraction end MXS6 (L) MXS8 (L) MXS12 (L) MXS16 (L) MXS20 (L) MXS25 (L) 10 5 30 13+0.15S 180 155 115 100 80 -X 15 35 9 45 40 40 26+0.17S 410 285 235 190 160 150 30 50 20 60 80 90 43+0.21S 890 660 480 385 325 325 325 Individual -X 50 80 30 105 120 160 55+0.21S 1700 1370 1090 760 640 580 570 570 100 170 71 205 140 310 150
Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.