SMC Corporation of America
Elite Part Number Search
Search Results "NCJ2D10-100T"

Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Screw

Cylinder (Tube) Inner Diameter(φ): 1/4", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m): N

Cylinder (Tube) Inner Diameter(φ): 3/8", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Basic, Auto Switches: Without auto switch, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Double Clevis, Auto Switches: Without auto switch, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 1/4", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.1~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 3/8", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 5/8", Stroke(mm): 1", Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Support bracket: Axial Foot, Auto Switches: Without auto switch, Lead Wire Length

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: D (Built-in Magnet), Series: 75 (Standard), Head Cover Type: E (Double End Boss-cut), Bore Size: 32mm, Stroke: 100mm, Action: T (Single Acting, Spring Extend), Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: A (Rail Mounting)

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73C--Reed, DC Volt >5 <24, LED, Connector

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)