Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 1200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Coil Scrapper
Magnet: None, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 1200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Coil Scrapper
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Series: Standard w/ Magnet, Mounting: MX0, Basic, Bore Size: 2 1/2", Stroke: 12", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Short Female, Threaded, Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: With Coil Scraper
Series: Standard, Mounting: MX0, Basic, Bore Size: 4", Stroke: 12", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Short Female, Threaded, Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: With Coil Scraper
Series: Standard, Mounting: MP2, Detachable Rear Clevis, Bore Size: 4", Stroke: 12", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Short Female, Threaded, Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: With Coil Scraper
to 4200) Setting of OUT1 output set value (Hysteresis) S16 2000 Y 1 R/W H_1 (Setting of OUT1 hysteresis) Setting range 0x0 to 0x1040 (0 to 4160) OUT1 setting (FloW) Setting of OUT1 hysteresis (Hysteresis) U16 200 Y 2 R/W P1L (n1L) (Lower limit of window comparator) Setting range 0x0028 to 0x1068 (40 to 4200) Setting of OUT1 output set value (Lower limit of window comparator) 3 R/W S16 1200
absolute H 20 24 30 L Left side parallel (Step motor 24 VDC) A 10 12 16 20 B 5 6 8 10 Stroke1[mm] Motor option Auto switch compatibility (In-line only) 23456 Nil Housing B bottom6 Positioning pin hole Grease application (Seal band part) 50 50 Nil Without option Nil With Nil None B With lock K Body bottom 2 locations N Without (Roller specification) C With (Includes 1 mounting bracket) 1200
Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.
Installation distance [mm] mm At maximum air flow (air flow scale: 4) 300 mm 300 0 4s 6s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm At minimum air flow (air flow scale: 1) 300 mm 300 6s 0 4s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm 18 - Doc. no.
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range
Piston speed (3) 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage MQQ M 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Supply pressure 0.3 MPa 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa RHC Note 1) Use clean, dry air with no freezing.
Stroke adjusting unit Cylinder stroke (mm) Nil L H LH Without adjusting unit With low load shock absorber + Adjusting bolt With high load shock absorber + Adjusting bolt With one L unit and one H unit each 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000 20, 25, 32, 40 50, 63 No stroke adjustment units are used for 50 and 63.
Stroke (mm) Tube material Mounting bracket Bore size (mm) 125 Aluminum alloy Basic, Rear flange, Single clevis, Double clevis, Center trunnion Carbon steel Basic, Rear flange, Single clevis, Double clevis, Center trunnion Foot, Front flange Front flange 1000 or less 1000 or less 1400 or less 1600 or less 140 1000 or less 1400 or less 1000 or less 1600 or less 160 1200 or less 1200 or less
Theoretical Cylinder Thrust JIS symbol 6, 10 15, 20, 25, 32, 40 1200 H H type 100 p40 40 1100 90 Bore size 10 1000 900 Mounting bracket type 80 Theoretical thrust (N) Theoretical thrust (N) Bore size Bore size 63 H H type L L type When mounting a floating bracket to a Series CY1B body, refer to P.67 for details, as this will be an order made product. 70 800 p32 32 700 60 600 50 500 p25 25