Low temperature operation Unless otherwise indicated in the specifications for each valve, operation is possible to -10C, but appropriate measures should be taken to avoid solidification or freezing of drainage and moisture, etc. 4. Operation for air blowing When using solenoid valves for air blowing, an external pilot type should be used.
Unless otherwise indicated in the specifications for each valve, operation is possible to -10C, but appropriate measures should be taken to avoid solidification or freezing of drain and moisture, etc. 4. Operation for air blowing. When using solenoid valves for air blowing, an external pilot type should be used.
The valve can be used at ambient temperatures as low as 10C, but take measures to prevent freezing or solidification of impurities, etc. 2. When used in cold areas with water, etc., adopt freeze prevention measures such as draining the water from pipelines after pump operation has been stopped. If warmed with a heater, etc., avoid the coil unit.
Low temperature operation Operation is possible to 10C, but measures should be taken to avoid solidification or freezing of drainage and moisture, etc. 3. Mounting orientation The mounting orientation is unrestricted. Switching element OFF Resistor Leakage voltage Valve Power supply Leakage current Mounting Warning 1.
Low temperature operation Avoid ambient temperatures outside the range of 10C to 50C. At low temperatures, measures should be taken to avoid solidification or freezing of drainage and moisture, etc. 4. Operation for air blowing When using solenoid valves for air blowing, an external pilot type or direct solenoid operated type should be used.
Low temperature operation Avoid ambient temperatures outside the range of 10C to 50C. At low temperatures, take any necessary steps to avoid solidification or freezing of drainage and moisture. 4. For air blowing applications When using solenoid valves for air blowing, use external pilot type valves.
Min. 40 1 60 5(1) 40 5 40 40 5 5(2) Note 1) Dew point: 10C or less. Note 2) 500cSt or less. Note 3) "V", "M" in the parenthesis are option symbols. Tightness of Valve(Leakage) Fluid Seal (2) Liquid Non-leak, Vacuum Air 1cm3/min 105atm cc/sec 0.1cm3/min(1) NBR, FPM, EPR Note 1) Differ from the operating condition of pressure. Note 2) Value on option "V", "M" (Non-leak, Vacuum).
PC 0101.1 10c Type "8" Alum. D.6. PC 0110.1 10D Alum. D.C. PC 0111-1 1 1 O-Ring , Operatol Buna N 12 Recessed Non-Locking Operator PB 0103 13 Gasket . Subplate BLrna N AXT 335-12.2 '14 Hold Down Bolts 32 x 1 n.')
Low temperature operation 1) Valve use is possible to temperature extremes of 10C. Take appropriate measures to avoid freezing of drainage, moisture etc. by using an air dryer. 2) When using valves for water application in cold climates, take appropriate countermeasures to prevent the freezing in tubing after cutting the water supply from the pump, e.g. drain the water, etc.
When using in an environment where the ambient and fluid temperature is low (10C or less) Note 4) The weight of a single unit of the valve includes a built-in EXH port silencer. Note 5) The flow rate of the body ported product with an external pilot decreases by 10%. Note 6) The flow rate of the body ported product with a built-in silencer decreases by 30%.
(Coil temperature: 20C, at rated voltage) Use of the product under the conditions and environment below may cause delay in the response (switching) of the valve during start-up. qThe first operation after a long period of inactivity wWhen using at low supply pressure (0.1 MPa or less) eWhen using in an environment where the ambient and fluid temperature is low (10C or less) *4 The flow rate
Fluid and Ambient Temperature Valve Leakage Internal Leakage Ambient temperature (C) Fluid temperature (C) Seal material Leakage rate (Air) Note) 1 cm3/min or less (AIuminum body type) 10 Note) to 50 10 to 50 NBR 15 cm3/min or less (Resin body type) Note) Dew point temperature: 10C or less External Leakage Seal material Leakage rate (Air) Note) 1 cm3/min or less (AIuminum body type) NBR 15
Low temperature operation 1) The valves can be used up to an ambient temperature of 10C, however take measures to prevent solidification of impurities or freezing, etc. 2) When using valves for water application in cold climates, first stop the water supply/discharge of the pump, etc., and then take measures to prevent freezing such as draining water in pipe.
D 5 port Port #4 on Coil side Voltage 3 110VDC 5 24VDC Manual override B Locking type (Tool required) Thread type N NPT Thread size 02 1/4 Specifications 5-way solenoid valve configuration (for Double acting actuator ) Fluid Air or inert gas Reverse function Normal function Working pressure range 21.8psi to 130psi (0.15 to 0.9 MPa) D-TYPE B-TYPE Ambient & Fluid Temperature 14F to 140F (10C
A1 E1 L1 MM NZ RR1 U1 ND L NX Y-04C 3 x 18l 16 + 0.3 + 0.1 22 24 55 M14 x 1.5 13 25 55.5 Polished round 12 38 12 Y-05C 50, 63 3 x 18l 16 + 0.3 + 0.1 27 28 60 M18 x 1.5 15 27 55.5 Polished round 12 38 12 Knuckle Pin, Clevis Pin Y-08C 80 4 x 25l 28 + 0.3 + 0.1 37 36 71 M22 x 1.5 19 28 76.5 Polished round 18 55 18 Y-10C 100 4 x 30l 30 + 0.3 + 0.1 37 40 83 M26 x 1.5 21 38 83 Polished round 20
Low temperature operation 1) Valve use is possible to temperature extremes of 10C. Take appropriate measures to avoid freezing of drainage, moisture etc. by using an air dryer. 2) When using valves for water application in cold climates, take appropriate countermeasures to prevent the freezing in tubing after cutting the water supply from the pump, e.g. drain the water, etc.
Auto switches are shipped together (not assembled). 464 Slide Unit/Double Rod Type Series CX2 Specifications Type Air-hydro type Non-lube Fluid Air Hydraulic fluid 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure CX2N10 CX215 CX225 0.15 MPa 0.15 MPa Min. operating pressure 0.10 MPa 10C to +60C Ambient and fluid temperature Refer to Table (1).
Auto switches are shipped together (not assembled). 464 Slide Unit/Double Rod Type Series CX2 Specifications Type Air-hydro type Non-lube Air Hydraulic fluid Fluid 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure CX2N10 CX215 CX225 0.15 MPa 0.15 MPa Min. operating pressure 0.10 MPa Ambient and fluid temperature 10C to +60C 30 to 200 mm/s Refer to Table (1).
-X 421 CK1 Series Specifications 50 40 63 Bore size (mm) Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa CKG1 Minimum operating pressure 0.05 MPa 10C to 60C Ambient and fluid temperature Piston speed 50 to 500 mm/s Cushion Unclamped side (head end): With air cushion Speed controller Equipped on both ends Lubrication Non-lube +1.0 0 Stroke length tolerance CKP1 Mounting
Specifications Bore size (mm) Item 6 10 15 20 25 32 40 50 63 1.05 MPa Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Stroke length tolerance 0.7 MPa 0.16 MPa 0.15 MPa 0.14 MPa 0.12 MPa 10C to 60C (No freezing) 50 to 400 mm/s 0 to 250 st: , +1.0 0 251 to 1000 st: , +1.4 0 Over 1001 st: +1.8 0 Mounting bracket Grease 2 mounting