SMC Corporation of America
Elite Part Number Search
Search Results "MDWBT80-250-N"

Initial value Recommended value Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 Electronic gear denominator *3 PA07 1 250 150 75 300 200 100 375 250 125 Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection PA14 0 1(+Counter motors side) Adaptive tuning mode PB01 0 0 Load to motor inertia moment ratio PB06

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

Grease apply amount( g ) 2 125 140 160 180 200 250 320 Portion to apply 100st 15~17 20~22 24~26 27~29 30~32 33~35 36~38 ~ 50st Up 3 3 3 4 4 5 5 For grease, use lithium soap group grease JIS #2 3. Mounting seal . Cushion seal/Rod seal /Scraper Mount in correct direction. N .

Fp: Generated extension force of cylinder (N) Fp: Generated retraction force of cylinder (N) Ff: Theoretical extension output (N) Ff: Theoretical retraction output (N) P: Operating pressure (MPa) D: Bore size (mm) d: Piston rod diameter (mm) 1: Cylinder extension load pressure coefficient 2: Cylinder retraction load pressure coefficient Formula (1) Formula (2) Fp = 1 x Ff Fp = 2 x Ff 4

2(B) port size 1(P), 3/5(R) port thread type 3/5(R) port 02 2 stations Rc 1/4 1 8 Rc Nil F N Z NPTE 01 Rc C6 One-touch fitting for 6 4(A), 2(B) port G 20 20 stations 1(P) port Rc 1/8, C6 NPT B7 One-touch fitting for 1/4" Rc 1/4 How to Order Type 43 VV5Z3 05 43 1 C4 1(P), 3/5(R) port thread type 4(A), 2(B) port size Stations 02 2 stations 3/5(R) port Nil F N Z NPTE Rc C4 One-touch fitting

Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500

PFMC7501 Item Default settings [P_1] Set value of OUT1 250 L/min [H_1] Hysteresis of OUT1 25 L/min [P_2] Set value of OUT2 250 L/min [H_2] Hysteresis of OUT2 25 L/min PFMC7102 Item Default settings [P_1] Set value of OUT1 500 L/min [H_1] Hysteresis of OUT1 50 L/min [P_2] Set value of OUT2 500 L/min [H_2] Hysteresis of OUT2 50 L/min PFMC7202 Item Default settings [P_1] Set value of OUT1 1000

/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175

Standard Stroke DMaximum manufacturable stroke Bore size (mm) -X Standard stroke (mm) 20700 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 800 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Data 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500

3 55.5 344 487 145 90 150 500 20 430 470 1 1 1 2 175 87.5 30 62.5 4 1 639 639 639 416.5 48 250 125 33.2 33.2 250 250 125 639 230 120 227 2 1 1055 ALD600/900 Series Related Products: Strainer At the terminal of an air pressure line in which a D.P.

(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.

250 600mm stroke L3 m 200 200 500mm or less 150 150 600mm stroke or less 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 300 300 250 250 Overhang direction:L4[mm] L4 m Overhang direction:L4[mm] 600mm stroke 200 200 600mm stroke or less 500mm stroke or less 150 150 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 500 500 600mm Wall Mounting 500mm or

Table 3.1-1 Weight of the product Model Weight kg Option increase HRL100-A-40 Approx.240 Option-D1:+1kg HRL200-A-40 Approx.260 Option-T2:+1kg HRL300-A-40 Approx.330 Option-T3:+18kg* HRL100-W-40 Approx.250 HRL200-W-40 Approx.250 *Applicable only to HRL300-A*-40. 3.1 Transport HRL Series 3-2 HRX-OM-X037 Chapter 3 Transport and Setting Up 3.1.2 Transportation using casters This is a heavy product

A Standard N/A Option (Part number: AP PL225) 6) 1) 14 to 194F (10 to 90C) for Vespel seat.

Applicable stroke table Stroke [mm] Size 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range 25 15 to 400 32 20 to 500 25 - .

Nil S n Bilateral piping type 1 pc. n pcs. Nil P2 P1 Auto switch Nil Without auto switch Centralized piping type Plate Refer to the table below for the applicable auto switch model. Note) Auto switch rail and magnet for auto switch included as standard. P1 P2 G Stopper type Note) For centralized piping, the port will be placed on the plate A side.

, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.

N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6 Paddle Style Flow Switch Series IF3 Fluid and Ambient Temperature Range Enclosure Open type Using indoors away from water drop.

. output 8 PT7 RY(n 2)9 Reserved RX(n 2)A RY(n 2)A Position/speed specifying system selection to Reserved RX(n 2)F selection RX(n 3)0 RY(n 2)B Absolute value/incremental value to Reserved RY(n 2)C RX(n 3)9 to Reserved RX(n 3)A Trouble ALM 15 RY(n 2)F RX(n 3)B Remote station communication ready CRD RY(n 3)0 to Reserved RX(n 3)C RY(n 3)9 to Reserved RY(n 3)A Reset RES RX(n 3)F RY(n 3)B to Reserved