(A, B port) 7 Manual override 2-1.8 (For monifold mounting) (Light/surge voltage suppressor) Bracket 2-3.2 equivalent (For mounting) (18.5) 28 [35] + (18.5) 22.1 13.5 12.6 15 (11.5) 0.5 10 R P R 1.2 (PE port) 14 M3 x 0.5 (P, R port) L plug connector (L): SYJ3 20-L-M3 (-F) M8 connector (W0): SYJ3 20-W0-M3 (-F) M plug connector (M): SYJ3 20-M-M3 (-F) 3 4 5 3 4 5 3 4 5 Approx. 300 (Lead wire

YES Hysteresis mode OFF n_1 n_2 Large pressure and vacuum pressure [n] H (Fix hysteresis) = 3 digits H H ON Window comparator mode NO OFF n_1 n_2 Large pressure and vacuum pressure 3 For General Fluids High Precision Digital Pressure Switch Series ZSE50F/ISE50 Example of Internal Circuit and Wiring ZSE F/ISE --22(L)-(M) 50 60 50 60 ZSE F/ISE --30(L)-(M) 50 60 50 60 With analog output With

One-touch fitting for 8 C8 One-touch fitting for 10 One-touch fitting for 8 One-touch fitting for 10 One-touch fitting for 12 SY7000 3 position closed center C10 C8 C10 C12 V 6 VDC S 5 VDC 3 SY9000 R 3 VDC Rated voltage For AC ( Hz) 50 60 Thread type 3 position exhaust center One-touch fitting (Inch size) 1 100 VAC 2 200 VAC Nil Rc Symbol Port size Applicable series 4 F G 5 32" One-touch

SY3000-37-46A SYJ3 1 LO Z 1 3 2 3 For AC: SY3000-37-47A Double solenoid, 3 position type Type of actuation A, B port size 1 2 3 4 5 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 110 VAC (115 VAC) Symbol Nil M3 Port size Base mounted M3 x 0.5 Single solenoid SY3000-37-54A SY3000-37-55A Double solenoid, 3 position type Rated

XLAV/With solenoid valve J Port P (pressure port) N M K L P R Port R (exhaust port) (mm) M 3 3 3 3 4 4 L 8.5 8.5 8.5 8.5 12 12 K 13 14 23 25 29 39 J 16.5 16.5 17.5 17.5 29 29 N Model XLAV-16 XLAV-25 XLAV-40 XLAV-50 XLAV-63 XLAV-80 3 3 3 3 2 2 Other dimensions are the same as XLA. 7 Series XLC Normally Closed/Bellows Seal Air Operated Type How to Order XLC 16 F9N Switch quantity/Mounting

OUT2 (P_1 H_3OFF)OFF ON(P_1 H_2ON) ONOFF H_2H_4 (H_1 H_2 + H_4) P_1-70.0 kPaH_1:10.0 kPaH_2:5.0 kPaH_3:0.0 kPaH_4:1.0 kPa A ON OFF (FUNC) OUT2 () ON OFF ON OFF ON OFF OUT1 (V) H_2 -25NO.ZK2-OM00801-B <> A [F 2] ON OFF OFF ON ON [F 2] OUT2 1 2 2 3ON(H_4)OFF(H_2) -26NO.ZK2-OM00801-B [F 3] <> [F 3] [F 3] -27NO.ZK2-OM00801-B [F 4] <> [F 4] [F 4] (29) ON/OFF -28NO.ZK2

MM 2-RcP G G MM D D e e Effective thread Effective thread 13 13 9 A K f N N f h + Stroke K A l + Stroke 9 l ZZ + 2 strokes S + Stroke h Without Air Cushion Stroke range Bore size (mm) Effective thread length Width across flats MB J K MM N P V W S ZZ S ZZ A C B D Ee11 F G H 32 40 50 63 80 100 4 4 5 5 5 5 M6 x 1 6 6 7 7 10 10 M10 x 1.25 26.5 26.5 31 31 37.5 37.5 1/8 1/4 1/4 3/8 3/8 1/2 84

Set temperature 40.0 oC (104.0 oF) (-)2 5.0 to 55.0 oC (41.0 to 131.0 oF) Circulating fluid Monitoring method AL03 discharge temp. 0 0 to 3 rise Monitoring start timer ---(0)3 0 to 600 minutes Range over detection timer 5 5 to 999 seconds 1: Values in F are displayed when SE12 is set to F. 2: Default value when AS03 is set OFF. 3: Default value when AS21 is set to either 2 or 3.

XT661-2A: F = f x (1/t) = 0.8 x (1/2) = 0.4 N XT661-4A: F = f x (1/t) = 3.8 x (1/2) = 1.9 N XT661-6A: F = f x (1/t) = 5.9 x (1/2) = 2.95 N XT661-8A: F = f x (1/t) = 7.5 x (1/2) = 3.75 N XT661-10A: F = f x (1/t) = 14.4 x (1/2) = 7.2 N 9700 g 9700 x 9.8/1000 = 95.06 N XT661-10A: Temporary lifting force 11.2 N < Workpiece mass 9700 g (95.06 N) 3) Confirm the relationship temporary lifting force

EX600-DY#E/F (15 byte) Byte Bit Parameter Setting value 0..3 Unit No. 0..8 0 4..7 Parameter type 1 1 0..7 Unit ID EX600-DY#E: 18 (Hex) EX600-DY#F: 1A (Hex) Unit parameter 0 Reserved 0 1 Monitor short circuit (out) 0: disable, 1: enable 2 2 Reserved 0 3 Restart after output load short circuit 0: manual, 1: auto 4..7 Reserved 0 Channel parameter Channel 0 to 7 0 (Ch0 output) Monitor counter

Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Connector Terminal conduit DIN terminal Grommet 12 V 2-wire 24 V PLC Relay, PLC 100 V, 200 V Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC Yes 24 V 12 V 3-wire (NPN) 3-wire (PNP)

0.76 (A)4 2(B) 1 (P) (EA)5 3(EB) 2 position double VFA1000 VFA3000 (B)2 4(A) 5(EA) 1 (P) (EB)3 Body ported Base mounted VFA3000 VFA5000 1/8 1/4 4.0 P.1498 2(B) (A)4 (EA)5 1 (P) 3(EB) Upward 3 position closed center 2(B) (A)4 VFA5000 (EA)5 1 (P) 3(EB) 3 position exhaust center 2(B) (A)4 1/4 3/8 8.8 (EA)5 1 (P) 3(EB) 3 position pressure center 2(B) (A)4 Lateral (EA)5 1 (P) 3(EB) VFA3000 2

Procedure 3 Confirmation of allowable lateral load 1. Calculation of applied lateral load F The lateral load F equals the coefficient between the workpiece and the conveyor. Thus, from the total amount of the work piece and coefficient of friction, F = x m g (N) 1. Calculation of applied lateral load The lateral load F equals the total load of the workpiece. Thus, F = x m g (N) 2.

Procedure 3 Confirmation of allowable lateral load 1. Calculation of applied lateral load F The lateral load F equals the coefficient between the workpiece and the conveyor. Thus, from the total amount of the work piece and coefficient of friction, F = x m g (N) 1. Calculation of applied lateral load The lateral load F equals the total load of the workpiece. Thus, F = x m g (N) 2.

Series 2 3 4 Class 2 Class 3 Class 4 OUT port size Port size 1/8 (6A) 1/4 (8A) All IN ports are 3/8.

Symbol Nil AFF Symbol N 3/8 inch Drain tube O.D.

Use 2 port valve VNH33. 4.2-33 VNH Dimensions Dimensions (mm) Model Main port 2 port 3 port Pilot port H I A C B D E F G 3 8 3 8 Rc(PT) 1 8 2-Rc(PT) 2-Rc 3-Rc(PT) 3-Rc 50 60 79 90 77 95.5 111 119 60 80 100 115 235.5 265 300 319.5 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 1 2 3-Rc 3 4 3-Rc1 Rc1 4 Rc1 4 Rc1 8 1