SMC Corporation of America
Elite Part Number Search
Search Results "LEY100NNB-300M"

Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 3", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 3", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 3", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod End, Auto

Cylinder (Tube) Inner Diameter(φ): 3", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Size: 100, Motor Mounting Position: D (In-line), Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: L (2mm), Stroke: 300mm, Motor Option: w/o Option, Rod End Thread: M (Rod End Male Thread), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 2 (2m), Driver Type: 92 (LECSN2-T9-9/EtherNet/IPâ„¢, 200V to 240V), I/O Cable Length: 1

Size: 100, Motor Mounting Position: D (In-line), Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: L (2mm), Stroke: 300mm, Motor Option: w/o Option, Rod End Thread: M (Rod End Male Thread), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 2 (2m), Driver Type: 92 (LECSN2-T9-9/EtherNet/IPâ„¢, 200V to 240V), I/O Cable Length: 1 (1.5m)

Size: 100, Motor Mounting Position: D (In-line), Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: B (10mm), Stroke: 300mm, Motor Option: w/o Option, Rod End Thread: M (Rod End Male Thread), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Driver Type: 92 (LECSN2-T9-9/EtherNet/IPâ„¢, 200V to 240V)