Mount a unit to the D side of the manifold MJ1 EX12 S D 6 Unit specifications Communication protocol MJ1 CC-Link Separate power supply of unit and valve Enclosure IP67 Compatible with SV/VQC valves 6 Mounting specifications D Mount a unit to the D side of the manifold 1653 Series EX123/124/126 How to Order Option Fuse for replacement A fuse for replacement used for EX126D-SMJ1.
For detailed specifications, refer to page 10-20-1. 50 7 63 9 80 9.5 100 10.5 CV D-Z7/Z80 D-A3/A44 D-A3C, D-A44C D-A5/A6 D-B5/B64 D-A59W D-B59W D-Y5/Y6 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL D-G59F D-G39/K39 D-G39C, D-K39C MVGQ Electrical entry (Fetching direction) D-A53/A56 D-A64/A67 D-B64 D-Z80 D-F59/F5P/J59 D-F59W/F5PW/J59W
Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006
4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4
Cable 6 to 12 Model Grommet Electrical entry Bracket Conduit Conduit terminal DIN terminal R Q 59 59 60 P Port size Rc VXD2140 Q R a b c d e f M L K J H F E D C B A N 69 (76) 77 (84) 87 (97) Q N 61 69 79 Q N 61 (68) 69 (76) 79 (89) N 61 (68) 69 (76) 79 (89) Normally open Normally closed VXD2142 , 30 30 35 59 59 62 57 74 81 34 51 58 29 37 43 34 43 47 20 20 23 92 92 95 104 (116) 26 44 59 66
9.4.1 HRS030--20-(BJMT) . 9-6 9.5 Heating capacity . 9-6 9.5.1 HRS030-A-20-(BJMT) . 9-6 9.5.2 HRS030-W-20-(BJMT) . 9-6 9.6 Pump capacity. 9-7 9.6.1 HRS030--20-(BJM) . 9-7 9.6.2 HRS030--20-T . 9-7 HRS Series HRX-OM-R016 Contents 9.6.3 HRS030--20-MT . 9-8 9.7 Required facility water flow (for water-cooled type) . 9-8 9.8 Compliance . 9-9 9.9 Sample DoC. . 9-10 9.10 Daily Check Sheet . 9-11
Fail Action Fail to Close, Fail to Open 5 Valve Travel 85.2 % 5 Positioner Information 5 Dead Angle (a0) 0.0 % [0..99%] 6 Temperature 24.7 C 6 Units 6 Performance Level A(1)-Aggressive, b(1)-fast, C(1)-Optimum, d(1)-Stable, E-Max. stability, (1) = Capac.
10 20 10 11 16 21 26 31 36 41 1 6 16 9.5 19 MB1 16 11 16 21 26 31 36 41 1 6 18 12 24 CA2 Applicable Auto Switches: D-M9, D-M9V, D-M9W, D-M9WV B (When detecting at retracted stroke end position) (mm) CS1 Bore size A (When detecting at extended stroke end position) 5 st H1 H2 H3 10 st 15 st 20 st 25 st 30 st 35 st 40 st CS2 4 14 19 4 9 14.5 11.5 23 6 15 20 25 30 5 10 15 11.5 23 10 15 20
capacityW 1500 e e 1500 40 32 25 20 5 40 32 25 20 5 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz Fig. 9-6 Heating capacity(HRS060-W-20-(BJM)) HRS Series 9.4 Cooling capacity 9-7 HRX-OM-R005 Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRS060--20-(BJM) 0.7 70 0.6 60 Circulating fluid pressure[MPa]
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 ASG22F-M5 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 M5 x 0.8 6, 10, 16, 20 R1/8 20, 25, 32 R1/4 20, 25, 32, 40 R3/8 40, 50, 63 R1/2 63, 80, 100 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure 0.1 MPa Ambient and fluid temperature 5 to 60C (No freezing) Number of needle rotations 10 turns
(n 2) 2 D-C7 D-C80 15 + 45 10 15 50 50 + 45 (n 2) (n = 2, 4, 6...) D-H7 D-H7W D-H7BAL D-H7NF (n 2) 2 15 + 45 60 + 45 (n 2) 10 15 60 (n = 2, 4, 6...) (n 2) 2 D-C73C D-C80C D-H7C 15 + 50 65 + 50 (n 2) 10 15 65 (n = 2, 4, 6...) D-B5/B64 D-G5/K59 D-G5W/K59W D-G5BAL D-G5NTL (n 2) 2 15 + 50 75 + 55 (n 2) 10 15 75 (n = 2, 4, 6...) (n 2) 2 20 + 50 D-B59W 75 + 55 (n 2) 15 20 75 (n = 2, 4, 6...)
Note) The applicable cylinder bore sizes (mm) for AS1002F-02 are 2.5, 4, 6.
Printed in Japan. 1st printing September, 1999 D-SMC.L.A. P-80 (D)
Refer to pages 17-6-3 to 17-6-10 for Safety Instructions and Solenoid Valve Precautions. Example 3) Discharge rate 5l/min, when operating 8 h/D (for PA5000 automatically operated type) Maintenance Caution Discharge rate 5 0.100 50 (cycles/min) = = Cycles per minute Discharge per cycle 6.
(5 Port / Body ported type) Applicable solenoid valve: SYJ3 20-M3 SYJ3 23-M3 SS5YJ3--20-05 AB Port M3 0.5 Applicable blank plate ass'y: SYJ3000-21-1A Valve stations 02 2 stations : : P Port M5 0.8 R Port M5 0.8 20 20 stations Type 31(4 Port / Base mounted type) Type 31 Type S31( ) Single solenoid coil is located on same side as the A, B port.
Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
Applicable bore size C D d H Applicable bore size C D d H 5 12.5 15 26 30 M8 x 1.25 8 M22 x 1.5 26 13 20 20 SOR-20 NT-02 6 16.5 19.6 32 36.9 M10 x 1.25 8 M24 x 1.5 32 17 25/32 25 SOR-25 NT-03 8 21.0 25.4 38 43.9 M14 x 1.5 9 M30 x 1.5 38 22 40 32 SOR-32 NT-04 11 26 31 41 47.3 M18 x 1.5 11 M33 x 2.0 41 27 50 40 SOR-40 NT-05 11 26 31 M18 x 1.5 27 63 NT-05 13 31 37 M22 x 1.5 32 80 NT-08 16 39
Enter together in order, counting from station 1 on the D side. Series 2 3 4 Class 2 Class 3 Class 4 OUT port size Symbol 01 02 Port size 1/8 (6A) Stations 2 3 4 5 n Uside D side 1/4 (8A) Material All IN ports are 3/8.
O-ring O, @, O Non plug-in type ME263LR-o2-1 Plug-in type Conneclor lead wires With terminal block. o @ End plate (kit) asJY ME272LR-02-1 End Plate (U) lD, End plate (D) (D ,Clamp O ' O o-rins G), O, O, O. Non plug-in type 1!