08 8 (Metric) 09 5/16" (Inch) Symbol Type 01 AC adapter (With AC cord*2) 02 AC adapter (Without AC cord) 03 Power supply cable (For 24 VDC wiring) N None Symbol Type 01 Standard nozzle 02 Bypass nozzle*3 *1 The AC adapter body and the power supply cable (For AC adapter) come as a set.

Model/Series SYA340 (Base mounted) Valve model Type of actuation Port size Flow characteristics Note 1) Mass Note 2) Pilot port size b 4/2 5/3 (A/B EA/EB) 1 4/2 (P A/B) (g) Cv b Cv C (dm3/ (sbar) ) C (dm3/(sbar) ) 69 (34) 71 (36) Single Double 2 position 0.30 1.0 0.24 1.1 0.30 0.26 0.28 0.18 0.85 0.30 0.77 M5 x 0.8 0.19 Closed center Exhaust center Pressure center SYA340-01 1 8 3 position

Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VR 2 3.2 (For mounting) VH VHS Manual override (Non-locking) 1.8 (Ventilation hole) 2 1.5 die-cast hole (For manifold gasket positioning) 1/8 (P , EA, EB port) SYA5120-01 1/8 (A, B port) 5-2-11 10 Series SYA3000/5000/7000 Series SYA5000: Body Ported SYA5220-01

AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500

25 M For positive pressure ZSE30 01 25 M For vacuum/low pressure Option 2 Piping specifications Nil None Bracket R 1/8 (With M5 female thread) 01 NPT 1/8 (With M5 female thread) A T1 Straight type 4 One-touch fitting 5/32" One-touch fiting C4H Output specifications Panel mount 25 65 26 28 NPN output PNP output 1 to 5 V output 4 to 20 mA output C6H 6 One-touch fitting B N7H 1/4" One-touch

First, tighten the threaded portion by hand, then use a proper wrench, which could be suitable for the width across flats of the hexagon body, to tighten it further at a wrench tightening angle shown in the table below. For a tightening torque guide, refer to the table below. For R, NPT Thread (With sealant) Tightening method 1.

Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air

For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

N2 gas Packaging Clean gas filter Class 10,000 Class 10,000 Features 1 Precision Clean Regulator Series SRP How to Order SRP 1 R 1 0 1 01 Set pressure Gauge port orientation Nil: Standard 0.005 to 0.2MPa 0 OUT IN 1 0.01 to 0.4MPa Knob Gauge port R: R specifications Gauge port JIS symbol Port size Piping port size M5 x 0.8 Rc 1/8 Symbol M5 01 OUT IN Gauge port positions are indicated with

N2 gas Packaging Clean gas filter Class 10,000 Class 10,000 Features 1 Precision Clean Regulator Series SRP How to Order SRP 1 R 1 0 1 01 Set pressure Gauge port orientation Nil: Standard 0.005 to 0.2MPa 0 OUT IN 1 0.01 to 0.4MPa Knob Gauge port R: R specifications Gauge port JIS symbol Port size Piping port size M5 x 0.8 Rc 1/8 Symbol M5 01 OUT IN Gauge port positions are indicated with

(c)When a sensor is not connected.

When very clean air is required, install a separator as mentioned above on the downstream side, or instead of a regulator, use the order made specification (refer to page 35) fitted with a micro mist separator regulator (series AWD). 3.

Port size ASV Model M3 x 0.5 ASV120F-M3 0.3 0.3 AK M5 x 0.8 ASV220F-M5 1.3 1.3 R 1/8 ASV310F-01 8 7 ASS R 1/4 ASV310F-02 8 7 R 1/8 ASV410F-01 14 13.5 ASR R 1/4 ASV410F-02 14 13.5 R 3/8 ASV410F-03 14 13.5 ASF R 1/4 ASV510F-02 27 23 R 3/8 ASV510F-03 29 27 R 1/2 ASV510F-04 29 27 10-32 UNF 1.3 1.3 ASV220F-U10/32 NPT 1/8 ASV310F-N01 8 7 NPT 1/4 ASV310F-N02 8 7 NPT 1/8 ASV410F-N01 14 13.5 NPT 1

Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AMD650 is obtained when the max. flow line is above the point of intersection A in the graph. Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.

Because tube fittings are provided, use a tube with a bore of 10mm, and keep the overall pipe length within 5m. AMH850 type (N.O) Use a tube with a bore of 9mm or more, and keep the overall pipe length within 2.8m.

Base, Body Seal material Aluminum NBR, FKM, EPDM LQ Port A Port A LVN Port P TI/ TIL Port R Energized open Energized closed PA PAX PB Model Manifold base model Port A Rc Port P Rc Port R Rc VVXA311-stations VVXA312-stations VVXA321-stations VVXA322-stations Manifold Manifold stations Manifold B mount 2 to 10 stations 1 8 1 4 1 8 1 4 1 4 1 4 17-3-105 The VX series will be revised shortly.

Flow Rate Characteristics Operating Frequency Port size Valve flow rate characteristics 70 Ambient and fluid temperatures (Upper limit) [C] 1, 5, 3 (P , EA, EB) 4, 2 (A, B) 1 R 4/2 (P R A/B) 4/2 R 5/3 (A/B R E) Model 60 C [dm3/(sbar)] b C [dm3/(sbar)] b DXT1215 1/8 1/8 1.3 0.37 1.3 0.23 50 Calculation of effective area S and sonic conductance C: S = 5.0 x C 40 30 20 10 0 0 200 Operating

B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3

For futhr details ol accessorbs. reler lo 'accessorles' on page 6. 4 rP300 METHOD OF OPERATION Signal pressure from a controlled pressure source enters the 1P300 input chamber and exerts a force on the diaphragms. A pressure differential between the two diaphragms creates a force to open the pilot valve.